Harmonic distortion in electric distribution system is increasingly growing due to the widespread use of nonlinear loads. Large concentrations of these loads have the potential to raise harmonic voltages and currents in an electrical distribution system to unacceptable high levels that can adversely affect the system. Hence there is need to study the impact of nonlinear loads in the system. This paper presents a method based on bispectrum analysis to characterize typical single phase nonlinear loads by analyzing the harmonic currents produced by these loads. Measurements are conducted using a power quality monitor to record the harmonic current waveforms, individual harmonic distortion levels and total harmonic distortion. To investigate the harmonic characteristics of these loads, the fast Fourier transform technique and the advance signal processing technique such as the bispectrum analysis are used. The results of harmonic characteristics obtained from these loads are compared so as to investigate the effectiveness of the bispectrum analysis in characterizing the various nonlinear loads.

Similar Papers
  • Conference Article
  • Citations2

Research on harmonic current distribution of beijing's rail traffic power supply system

  • Aug 01, 2009
  • Yuan Haiwen +3
  • Research Article
  • Citations3

Power quality enhancement using active power filter five-level cascade H-bridge under unbalanced and distorted grid

  • Jan 04, 2023
  • Electrical Engineering & Electromechanics
  • M Guergah +4
  • Research Article
  • Citations2

Simulation of passive filter design to reduce Total Harmonic Distortion (THD) in Energy-Saving Lamps (LHE) and Light Emitting Diodes (LED)

  • Oct 01, 2021
  • IOP Conference Series: Earth and Environmental Science
  • F Susanto +4
  • Research Article

The production of residual currents due to harmonic loading

  • Jul 01, 1985
  • IEE Proceedings Generation, Transmission and Distribution [see also IEE Proceedings-Generation, Transmission and Distribution]
  • Ge Littler
  • Conference Article

Comparative Analysis of Fuzzy-Controlled and ANN Based UPQC for Grid Voltage Regulation and Dynamic Load Compensation in Three-Phase Systems

  • Dec 06, 2025
  • B.S.Nivethitha +3
  • Research Article
  • Citations39

Adaptive shunt filtering control of UPQC for increased nonlinear loads

  • Jan 08, 2019
  • IET Power Electronics
  • Saurav Roy Choudhury +4
  • Conference Article
  • Citations6

Mitigation of total harmonic distortion using cascaded MLI-DSTATCOM in distribution network

  • Sep 01, 2017
  • Khushaboo Rani Shandilya +1
  • Research Article
  • Citations2

Single-Phase Grid Connected Axial Flux Permanent Magnet Generator System with Harmonic Mitigation Functionality for Various Types of Nonlinear Loads

  • Apr 30, 2018
  • International Review of Electrical Engineering (IREE)
  • Poonsri Wannakarn +1
  • Book Chapter
  • Citations7

41 - Active Filters

  • Jan 01, 2011
  • POWER ELECTRONICS HANDBOOK
  • Luis Morán +1
  • Research Article

Fuzzy Logic-Based Control for Shunt Active Power Filter using Instantaneous PQ Theory

  • Oct 10, 2025
  • International Journal of Advanced Research in Science, Communication and Technology
  • Kiran Vasant Chavan +1
  • Research Article
  • Citations14

A Method to Estimate the Impact of Harmonic and Unbalanced Currents on the Ampacity of Concentric Neutral Cables

  • Oct 01, 2016
  • IEEE Transactions on Power Delivery
  • Jing Yong +1
  • Conference Article
  • Citations10

Improvement of the stand-alone DFIG performance feeding nonlinear and unbalanced loads using active and reactive power theory

  • Oct 01, 2015
  • F Khalilzadeh Moghaddam +1
  • Conference Article
  • Citations8

Hysteresis current controlled active power filter for power quality improvement in three phase four wire electrical distribution system

  • May 01, 2014
  • D Bharath Kumar +2
  • Research Article
  • Citations8

A Real-Time Current Harmonic Monitoring System Based on Stockwell Transform Method

  • Apr 30, 2016
  • International Review of Electrical Engineering (IREE)
  • Margo Pujiantara +5
  • Research Article

Adaptive filter based current controller for Shunt Active filter

  • Apr 25, 2018
  • International Journal of Engineering & Technology
  • R Sriranjani +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.