• Home
  • Search
  • Comparison between two-dimensional and three-dimensional imaging utilizing the Grummons frontal analysis
  • https://doi.org/10.25259/apos_73_2025Copy DOI Icon

Comparison between two-dimensional and three-dimensional imaging utilizing the Grummons frontal analysis

Show More
  • Abstract
  • Literature Map
  • References
  • Similar Papers
Abstract

Objectives: The purpose of this study is to compare the parameters of the Grummons analysis applied to the cone beam computer tomography (CBCT) constructed posteroanterior (PA) cephalograms and multiplanar reconstructions (MPRs) slices. Material and Methods: Pre-treatment cone-beam computed tomography (CBCT) scans of 39 orthodontic patients aged between 8 and 13 years old were retrospectively chosen from the Department of Orthodontics and Dentofacial Orthopedics at the Lebanese University. PA cephalograms were reconstructed from CBCT scans. Skeletal landmarks were identified and analyzed on both imaging techniques using the Viewbox 4 cephalometric software. Results: For all eleven linear measurements (CoR, CoL, JR, JL, Me, CoAgR, CoAgL, CoMeR, CoMeL, AgMeR, AgMeL), two angular measurements (CoAgMeR, CoAgMeL), and six ratios (UFRa, LFRa, MxRa, MdRa, TMdRa, MxMdRa) showed a statistically significant difference between the CBCT constructed PA cephalograms and their respective three-dimensional (3D) volumes ( P < 0.05). Conclusion: PA reconstructions and MPR slices were not comparable according to Grummons’ analysis, especially for measurements evaluating the mandibular symmetry and point Juguale. New and reliable 3D analyses are recommended to account for accuracy and 3D reality.

Similar Papers
  • Research Article
  • Citations7

Generating patient‐matched 3D‐printed pedicle screw and laminectomy drill guides from Cone Beam CT images: Studies in ovine and porcine cadavers

  • May 06, 2022
  • Medical Physics
  • Andrew Kanawati +4
  • Research Article
  • Citations25

Real-time Intraoperative Computed Tomography Assessment of Quality of Permanent Interstitial Seed Implantation for Prostate Cancer

  • Apr 29, 2010
  • Urology
  • Michael J Zelefsky +10
  • Research Article

Letters to the Editor.

  • Jun 01, 2016
  • Implant dentistry
  • Cleber Silva +1
  • Research Article
  • Citations33

Diagnostic value of cone-beam CT in histologically confirmed otosclerosis

  • Sep 19, 2013
  • European Archives of Oto-Rhino-Laryngology
  • Balázs Liktor +5
  • Research Article
  • Citations57

DentalSegmentator: Robust open source deep learning-based CT and CBCT image segmentation

  • Jun 13, 2024
  • Journal of Dentistry
  • Gauthier Dot +11
  • Research Article
  • Citations560

Comparison between effective radiation dose of CBCT and MSCT scanners for dentomaxillofacial applications

  • Jul 18, 2008
  • European Journal of Radiology
  • M Loubele +8
  • Research Article
  • Citations1

Correlation between Alveolar Cleft Measurements Performed with Periapical Radiography and Cone-Beam Computed Tomography

  • May 23, 2012
  • Kamilla Costa De Oliveira +4
  • PDF
  • Research Article

The enlargement of the maxillary ostium after balloon sinuplasty evaluated by a novel measuring technique from 3D CBCT images

  • Dec 01, 2021
  • Scientific Reports
  • Eerika Kalliomäki +3
  • Research Article
  • Citations79

Fast Monte Carlo simulation for patient-specific CT/CBCT imaging dose calculation

  • Jan 06, 2012
  • Physics in Medicine and Biology
  • Xun Jia +3
  • Research Article

Cephalometric Measurements on Conventional Posteroanterior Radiographs versus CBCT Images: A Comparative Study

  • Jan 01, 2020
  • SHILAP Revista de lepidopterología
  • Hourieh Bashizadeh Fakhar +1
  • Research Article

SU‐GG‐T‐503: Dose Calculation On Cone‐Beam Scans: A Correction Algorithm for Improved Dosimetry

  • Jun 01, 2008
  • Medical Physics
  • Cg Rowbottom +2
  • Research Article

Correlation between cone beam computed tomography-guided scheme and setup errors in nasopharyngeal carcinoma

  • Aug 28, 2018
  • Cancer Research and Clinic
  • Yibiao Chen +7
  • Research Article

SU-FF-J-84: Accuracy and Feasibility of Cone Beam Computed Tomography (CBCT) for Stereotactic Radiosurgery (SRS) Setup

  • May 26, 2005
  • Medical Physics
  • J Chang +6
  • PDF
  • Research Article
  • Citations1

Availability of Software-Based Correction of Mandibular Plane for the Vertical Measurement of the Mandible in Cone Beam Computed Tomography

  • Jan 01, 2015
  • BioMed Research International
  • Sang-Sun Han +2
  • Research Article
  • Citations11

"High-precision, reconstructed 3D model" of skull scanned by conebeam CT: Reproducibility verified using CAD/CAM data.

  • Nov 24, 2015
  • Legal medicine (Tokyo, Japan)
  • Seiko Katsumura +6
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.