Comprehensive fluence model for absolute portal dose image prediction

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Amorphous silicon (a-Si) electronic portal imaging devices (EPIDs) continue to be investigated as treatment verification tools, with a particular focus on intensity modulated radiation therapy (IMRT). This verification could be accomplished through a comparison of measured portal images to predicted portal dose images. A general fluence determination tailored to portal dose image prediction would be a great asset in order to model the complex modulation of IMRT. A proposed physics-based parameter fluence model was commissioned by matching predicted EPID images to corresponding measured EPID images of multileaf collimator (MLC) defined fields. The two-source fluence model was composed of a focal Gaussian and an extrafocal Gaussian-like source. Specific aspects of the MLC and secondary collimators were also modeled (e.g., jaw and MLC transmission factors, MLC rounded leaf tips, tongue and groove effect, interleaf leakage, and leaf offsets). Several unique aspects of the model were developed based on the results of detailed Monte Carlo simulations of the linear accelerator including (1) use of a non-Gaussian extrafocal fluence source function, (2) separate energy spectra used for focal and extrafocal fluence, and (3) different off-axis energy spectra softening used for focal and extrafocal fluences. The predicted energy fluence was then convolved with Monte Carlo generated, EPID-specific dose kernels to convert incident fluence to dose delivered to the EPID. Measured EPID data were obtained with an a-Si EPID for various MLC-defined fields (from 1 x 1 to 20 x 20 cm2) over a range of source-to-detector distances. These measured profiles were used to determine the fluence model parameters in a process analogous to the commissioning of a treatment planning system. The resulting model was tested on 20 clinical IMRT plans, including ten prostate and ten oropharyngeal cases. The model predicted the open-field profiles within 2%, 2 mm, while a mean of 96.6% of pixels over all IMRT fields was in agreement with the 2%, 3 mm criteria. This model demonstrates accuracy commensurate to existing methods for IMRT pretreatment verification with portal dose image prediction of complex clinical examples (< 2%, 3 mm).

Similar Papers
  • Research Article

Sci-Thurs PM: Delivery-04: Comprehensive fluence model for absolute portal dose image prediction in IMRT pre-treatment verification.

  • Jul 01, 2008
  • Medical physics
  • K Chytyk +1
  • Research Article
  • Citations1

SU‐GG‐T‐188: A Field Size Specific Backscatter Correction Algorithm for Accurate EPID Dosimetry

  • Jun 01, 2010
  • Medical Physics
  • S Berry +2
  • Abstract
  • Citations1

OA236] Patient-specific quality assurance based on electronic portal imaging devices via artificial neural networks

  • Aug 01, 2018
  • Physica Medica
  • Frédéric Chatrie +8
  • Research Article
  • Citations3

Feasibility Study of Patient Specific Quality Assurance Using Transit Dosimetry Based on Measurement with an Electronic Portal Imaging Device

  • Jan 01, 2017
  • Progress in Medical Physics
  • Tae Seong Baek +3
  • Research Article

Transmission portal in vivo dosimetry by means of the Monte Carlo method and the mathematical programming language MATLAB

  • Jun 06, 2014
  • Radioprotection
  • K Badraoui Čuprová
  • PDF
  • Research Article
  • Citations14

Dosimetry in radiotherapy using a-Si EPIDs: Systems, methods, and applications focusing on 3D patient dose estimation

  • Jun 26, 2013
  • Journal of Physics: Conference Series
  • B M C Mccurdy
  • Abstract

Potential for Dose-escalation in the Post-prostatectomy Setting with Intensity Modulated Radiation Therapy: A Dosimetric Study using EORTC Consensus Guidelines for Target Volume Contours

  • Sep 30, 2010
  • International Journal of Radiation Oncology*Biology*Physics
  • M.T Studenski +8
  • Research Article

SU‐FF‐T‐201: Implementation of EPID Based Quality Assurance Procedures for Radiation and Optical Fields

  • May 26, 2005
  • Medical Physics
  • J Smale +5
  • Research Article
  • Citations65

First Experience With Real-Time EPID-Based Delivery Verification During IMRT and VMAT Sessions

  • Jul 22, 2015
  • International Journal of Radiation Oncology*Biology*Physics
  • Henry C Woodruff +6
  • Research Article
  • Citations1

Dosimetric effect of multi-leaf collimator transmission on intensity-modulated radiation therapy

  • Mar 15, 2013
  • Chinese Journal of Radiation Oncology
  • Ruijie Yang +3
  • Research Article
  • Citations6

Denoising techniques combined to Monte Carlo simulations for the prediction of high-resolution portal images in radiotherapy treatment verification

  • Apr 26, 2013
  • Physics in Medicine and Biology
  • D Lazaro +6
  • Research Article
  • Citations2

Assessment of a 2D electronic portal imaging devices-based dosimetry algorithm for pretreatment and in-vivo midplane dose verification

  • Jan 01, 2016
  • Advanced Biomedical Research
  • Ali Jomehzadeh +3
  • Research Article
  • Citations44

Verification of step-and-shoot IMRT delivery using a fast video-based electronic portal imaging device.

  • Feb 06, 2004
  • Medical physics
  • Omar A Zeidan +4
  • Research Article
  • Citations3

Use of electronic portal imaging devices for electron treatment verification

  • Nov 18, 2015
  • Australasian Physical &amp; Engineering Sciences in Medicine
  • T Kairn +3
  • Research Article
  • Citations19

Treatment Efficiency of Volumetric Modulated Arc Therapy in Comparison With Intensity-Modulated Radiotherapy in the Treatment of Prostate Cancer

  • Dec 12, 2012
  • Journal of the American College of Radiology
  • William A Hall +6
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.