• Home
  • Search
  • Computational Flow Diverter Implantation—A Comparative Study on Pre-Interventional Simulation and Post-Interventional Device Positioning for a Novel Blood Flow Modulator
  • Cite Icon3
  • https://doi.org/10.3390/fluids9030055Copy DOI Icon

Computational Flow Diverter Implantation—A Comparative Study on Pre-Interventional Simulation and Post-Interventional Device Positioning for a Novel Blood Flow Modulator

  • Feb 23, 2024
  • Fluids
  • Maximilian Thormann +8 more
Show More
  • Abstract
  • Highlights & Summary
  • PDF
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Due to their effect on aneurysm hemodynamics, flow diverters (FD) have become a routine endovascular therapy for intracranial aneurysms. Since over- and undersizing affect the device’s hemodynamic abilities, selecting the correct device diameter and accurately simulating FD placement can improve patient-specific outcomes. The purpose of this study was to validate the accuracy of virtual flow diverter deployments in the novel Derivo® 2 device. We retrospectively analyzed blood flows in ten FD placements for which 3D DSA datasets were available pre- and post-intervention. All patients were treated with a second-generation FD Derivo® 2 (Acandis GmbH, Pforzheim, Germany) and post-interventional datasets were compared to virtual FD deployment at the implanted position for implanted stent length, stent diameters, and curvature analysis using ANKYRAS (Galgo Medical, Barcelona, Spain). Image-based blood flow simulations of pre- and post-interventional configurations were conducted. The mean length of implanted FD was 32.61 (±11.18 mm). Overall, ANKYRAS prediction was good with an average deviation of 8.4% (±5.8%) with a mean absolute difference in stent length of 3.13 mm. There was a difference of 0.24 mm in stent diameter amplitude toward ANKYRAS simulation. In vessels exhibiting a high degree of curvature, however, relevant differences between simulated and real-patient data were observed. The intrasaccular blood flow activity represented by the wall shear stress was qualitatively reduced in all cases. Inflow velocity decreased and the pulsatility over the cardiac cycle was weakened. Virtual stenting is an accurate tool for FD positioning, which may help facilitate flow FDs’ individualization and assess their hemodynamic impact. Challenges posed by complex vessel anatomy and high curvatures must be addressed.

Loading PDF

Similar Papers
  • Research Article
  • Citations69

High-fidelity virtual stenting: modeling of flow diverter deployment for hemodynamic characterization of complex intracranial aneurysms.

  • Jun 19, 2015
  • Journal of Neurosurgery
  • Jianping Xiang +6
  • Research Article
  • Citations1

Flow alteration therapy for impending rupture of intracranial giant aneurysm after flow diverter placement.

  • Jul 29, 2022
  • Surgical neurology international
  • Daichi Yamasaki +10
  • Abstract
  • Citations5

E-235 Use of 45 mg twice daily ticagrelor with 81 mg aspirin for endovascular treatment of unruptured intracranial aneurysms: a single center experience

  • Aug 01, 2020
  • Journal of NeuroInterventional Surgery
  • T Mehta +5
  • Research Article
  • Citations2

Evaluation of coiling endovascular technique on treatment of middle cerebral artery cerebral aneurysms in different blood hematocrits: A numerical study

  • Nov 27, 2024
  • International Journal of Modern Physics C
  • Wankang Dian +6
  • Conference Article

Utilizing Stent Wall Shear Stress to Assess Stent and Flow Diverter Performance for Treating Intracranial Aneurysms

  • Oct 30, 2022
  • Taylor N Suess +1
  • Conference Article

P-028 coil me now. divert me later

  • Jul 01, 2015
  • Journal of NeuroInterventional Surgery
  • W Brinjikji +9
  • Research Article

Effect of the Effective Metal Surface Area of Two Different Flow Diverter Stents on the Stagnation Region Formation Inside the Aneurysm Sac.

  • Oct 21, 2024
  • Asian journal of neurosurgery
  • Muhammed Talha Gunaydin +5
  • Research Article
  • Citations35

Flow Diversion in Transcranial Doppler Ultrasound Is Associated with Better Improvement in Patients with Acute Middle Cerebral Artery Occlusion

  • Jan 01, 2006
  • Cerebrovascular Diseases
  • Yo Sik Kim +5
  • Research Article

Evaluating a biaxial radial workflow for flow diverter placement: clinical and technical outcomes using the RIST guide catheter.

  • Aug 01, 2026
  • Journal of clinical neuroscience : official journal of the Neurosurgical Society of Australasia
  • Victor Gabriel El-Hajj +14
  • PDF
  • Research Article
  • Citations2

Periprocedural Management during Placement of Flow Diverters in Intracranial Aneurysms: A Clinical Report and Review of Literature

  • Aug 04, 2019
  • Journal of Neuroanaesthesiology and Critical Care
  • Rajeeb K Mishra +3
  • PDF
  • Research Article
  • Citations5

CFD to Quantify Idealized Intra-Aneurysmal Blood Flow in Response to Regular and Flow Diverter Stent Treatment

  • Jul 28, 2022
  • Fluids
  • Augusto Fava Sanches +3
  • Research Article

Robust optimization of geometrical properties of flow diverter stents for treating cerebral aneurysm: A proof-of-concept study

  • Jan 01, 2024
  • Computer Methods and Programs in Biomedicine Update
  • Zahra Darbandi +2
  • Research Article
  • Citations84

Impact of Stents and Flow Diverters on Hemodynamics in Idealized Aneurysm Models

  • Jul 01, 2011
  • Journal of Biomechanical Engineering
  • Santhosh Seshadhri +4
  • Research Article
  • Citations75

Coronary arteries hemodynamics: effect of arterial geometry on hemodynamic parameters causing atherosclerosis.

  • Jun 09, 2020
  • Medical & Biological Engineering & Computing
  • Kelvin K L Wong +4
  • Research Article
  • Citations32

Three-dimensional computed tomography venogram enables accurate diagnosis and treatment of patients presenting with symptomatic chronic iliofemoral venous obstruction

  • Aug 12, 2020
  • Journal of Vascular Surgery: Venous and Lymphatic Disorders
  • Arjun Jayaraj +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.