• Home
  • Search
  • Computed tomography noise reduction based on total variation minimization and morphological component analysis
  • https://doi.org/10.32920/ryerson.14668290.v1Copy DOI Icon

Computed tomography noise reduction based on total variation minimization and morphological component analysis

  • May 24, 2021
  • Aryan Khodabandeh
Show More
  • Abstract
  • Highlights & Summary
  • Literature Map
  • References
  • Similar Papers
Abstract

X-ray Computed Tomography (CT) scans, while useful, emit harmful radiation which is why low-dose image acquisition is desired. However, noise corruption in these cases is a difficult obstacle. CT image denoising is a challenging topic because of the difficulty in modeling noise. In this study, we propose taking an image decomposition approach to removing noise from low-dose CT images. We model the image as the superposition of a structure layer and a noise layer. Total Variation (TV) minimization is used to learn two dictionaries to represent each layer independently, and sparse coding is used to separate them. Finally, an iterative post-processing stage is introduced that uses image-adapted curvelet dictionaries to recover blurred edges. Our results demonstrate that image separation is a viable alternative to the classic K-SVD denoising method.

Similar Papers
  • Research Article
  • Citations4

Deep learning-based low-dose CT simulator for non-linear reconstruction methods.

  • Jun 06, 2024
  • Medical physics
  • Sjoerd A M Tunissen +5
  • Research Article
  • Citations4

Isotropic and anisotropic filtering norm-minimization: A generalization of the TV and TGV minimizations using NESTA

  • Apr 18, 2020
  • Signal Processing: Image Communication
  • Jonathan A Lima +4
  • Research Article
  • Citations15

CT reconstruction from few-views with anisotropic edge-guided total variance

  • Feb 27, 2016
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • Junyan Rong +6
  • Research Article
  • Citations3

Positron emission tomography image reconstruction using feature extraction.

  • Oct 01, 2019
  • Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics
  • Juan Gao +9
  • Conference Article

Time-of-flight image reconstruction with TV minimization constraint for a dual-head small animal PET system

  • Oct 01, 2012
  • Hung-Yi Chou +4
  • Research Article
  • Citations11

A computer simulation method for low-dose CT images by use of real high-dose images: a phantom study.

  • Aug 20, 2015
  • Radiological physics and technology
  • Tomomi Takenaga +5
  • Conference Article
  • Citations29

Accurate image reconstruction in circular cone-beam computed tomography by total variation minimization: a preliminary investigation

  • Jan 01, 2006
  • Emil Y Sidky +1
  • Conference Article
  • Citations55

Simultaneous Visual Data Completion and Denoising Based on Tensor Rank and Total Variation Minimization and Its Primal-Dual Splitting Algorithm

  • Jul 01, 2017
  • Tatsuya Yokota +1
  • Conference Article
  • Citations2

Low-dose computed tomography image reconstruction from under-sampling data based on weighted total variation minimization

  • Feb 23, 2012
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Yan Liu +3
  • Research Article
  • Citations2

Noise-assisted hybrid attention networks for low-dose PET and CT denoising.

  • Oct 21, 2024
  • Medical physics
  • Hengzhi Xue +2
  • Research Article
  • Citations5

Photoacoustic tomography with a model-based approach involving realistic detector properties

  • Sep 20, 2023
  • Results in Optics
  • Pankaj Warbal +1
  • Conference Article
  • Citations9

Low dose CT image denoising method based on improved generative adversarial network

  • Jul 01, 2022
  • Xiangcan Wang +2
  • PDF
  • Research Article
  • Citations13

Accelerating an Ordered-Subset Low-Dose X-Ray Cone Beam Computed Tomography Image Reconstruction with a Power Factor and Total Variation Minimization.

  • Apr 13, 2016
  • PLOS ONE
  • Hsuan-Ming Huang +1
  • PDF
  • Research Article
  • Citations11

Artifact Suppressed Nonlinear Diffusion Filtering for Low-Dose CT Image Processing

  • Jan 01, 2019
  • IEEE Access
  • Yi Liu +4
  • Abstract
  • Citations1

High Quality 4-dimensional Cone Beam CT by Deforming Prior Images

  • Oct 25, 2012
  • International Journal of Radiation Oncology*Biology*Physics
  • J Wang +2
Cactus Communications logo