Abstract

The feasibility of computed tomography (CT) with energy-resolved x-ray detection has been investigated. A breast CT design with multi slit multi slice (MSMS) data acquisition was used for this study. The MSMS CT includes linear arrays of photon counting detectors separated by gaps. This CT configuration allows for efficient scatter rejection and 3D data acquisition. The energy-resolved CT images were simulated using a digital breast phantom and the design parameters of the proposed MSMS CT. The phantom had 14 cm diameter and 50/50 adipose/glandular composition, and included carcinoma, adipose, blood, iodine and CaCO3 as contrast elements. The x-ray technique was 90 kVp tube voltage with 660 mR skin exposure. Photon counting, charge (energy) integrating and photon energy weighting CT images were generated. The contrast-to-noise (CNR) improvement with photon energy weighting was quantified. The dual energy subtracted images of CaCO3 and iodine were generated using a single CT scan at a fixed x-ray tube voltage. The x-ray spectrum was electronically split into low- and high-energy parts by a photon counting detector. The CNR of the energy weighting CT images of carcinoma, blood, adipose, iodine, and CaCO3 was higher by a factor of 1.16, 1.20, 1.21, 1.36 and 1.35, respectively, as compared to CT with a conventional charge (energy) integrating detector. Photon energy weighting was applied to CT projections prior to dual energy subtraction and reconstruction. Photon energy weighting improved the CNR in dual energy subtracted CT images of CaCO3 and iodine by a factor of 1.35 and 1.33, respectively. The combination of CNR improvements due to scatter rejection and energy weighting was in the range of 1.71–2 depending on the type of the contrast element. The tilted angle CZT detector was considered as the detector of choice. Experiments were performed to test the effect of the tilting angle on the energy spectrum. Using the CZT detector with 20° tilting angle decreased the tailing of the measured x-ray spectrum as compared to a conventional CZT detector. It was concluded that the energy-resolved MSMS CT with tilted angle CZT detector is potentially feasible and could provide a unique combination of photon counting, energy weighting, scatter rejection and single kVp dual energy subtraction CT imaging.

Similar Papers
  • Research Article
  • Citations8

Nanoparticles: Untying the Gordian Knot in Conventional Computed Tomography Imaging

  • May 11, 2021
  • CCS Chemistry
  • Zhen Sun +5
  • Research Article
  • Citations9

Diagnostic value of quantitative parameters for myocardial perfusion assessment in patients with suspected coronary artery disease by single- and dual-energy computed tomography myocardial perfusion imaging.

  • Feb 01, 2021
  • IJC Heart & Vasculature
  • Aroa Ruiz-Muñoz +12
  • Research Article
  • Citations311

Four-dimensional CT scans for treatment planning in stereotactic radiotherapy for stage I lung cancer

  • Oct 29, 2004
  • International Journal of Radiation Oncology*Biology*Physics
  • René W.M Underberg +5
  • Research Article
  • Citations46

Deep learning-based image quality improvement for low-dose computed tomography simulation in radiation therapy.

  • Oct 24, 2019
  • Journal of Medical Imaging
  • Tonghe Wang +9
  • Abstract
  • Citations1

COMPARISON OF 3D QUANTITATIVE OSTEOARTHRITIS IMAGING BIOMARKERS: A STUDY USING PAIRED CT AND MR IMAGES FROM THE IMI-APPROACH STUDY

  • Jan 01, 2022
  • Osteoarthritis Imaging
  • A.D Brett +2
  • Research Article
  • Citations1

SU-E-T-225: It Is Necessary to Contouring the Brainstem On MRI Images in Radiotherapy of Head and Neck Cancer

  • May 29, 2014
  • Medical Physics
  • G Gong +1
  • Research Article
  • Citations25

Investigation of the LabPET™ detector and electronics for photon-counting CT imaging

  • Nov 15, 2006
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • Philippe Bérard +6
  • Supplementary Content

Extracting greater data from standard CT imaging in non-small cell lung cancer.

  • Feb 28, 2019
  • Iain Phillips
  • Research Article
  • Citations13

Comparative analysis of ResNet, ResNet-SE, and attention-based RaNet for hemorrhage classification in CT images using deep learning

  • Nov 02, 2023
  • Biomedical Signal Processing and Control
  • Shanu Nizarudeen +1
  • Abstract
  • Citations1

The Prognostic Value of Residual FDG-Avidity Prior to Allogeneic Stem Cell Transplantation for Lymphoma.

  • Nov 20, 2009
  • Blood
  • Craig S Sauter +5
  • Research Article
  • Citations23

The staging of renal-cell carcinomas in MRT and CT--a prospective histologically controlled study

  • Feb 01, 1998
  • RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin
  • P Hallscheidt +5
  • Abstract

MP25-01 CT VOLUMETRIC MEASUREMENTS ESTIMATE FUTURE SPLIT RENAL FUNCTION IN RENAL TRAUMA PATIENTS WITH SEGMENTAL VASCULAR INJURIES

  • Apr 01, 2018
  • The Journal of Urology
  • Paul H Chung
  • Research Article
  • Citations45

Optimal Measurement Modality and Method for Evaluation of Responses to Transarterial Chemoembolization of Hepatocellular Carcinoma Based on Enhancement Criteria

  • Jan 09, 2013
  • Journal of Vascular and Interventional Radiology
  • Ju Hyun Shim +7
  • Research Article
  • Citations16

Trends in oncological CT imaging: clinical application of multidetector-row CT and 3D-CT imaging

  • Sep 05, 2006
  • International Journal of Clinical Oncology
  • Takuya Ueda +4
  • Conference Article
  • Citations7

Segmentation and reconstruction of the lung and the mediastinum volumes in CT images

  • Nov 01, 2009
  • Sara Lioba Volpi +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.