Control strategy for maintaining physiological perfusion with rotary blood pumps.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

We present arguments and simulation results in favor of a novel strategy for control of rotary blood pumps. We suggest that physiological perfusion is achieved when the blood pump is controlled to maintain an average reference differential pressure. In the case of rotary left ventricular assist devices, our simulations show that maintaining a constant average pressure difference between the left ventricle and aorta results in physiological perfusion over a wide range of physical activities and clinical cardiac conditions. We simulated rest, light, and strenuous exercise conditions, corresponding to cardiac demands of 4.92, 7.98, and 14.62 L/min, respectively. For different exercise levels, the clinical conditions ranged from normal to failing to asystolic heart. By maintaining a constant pressure difference of 75 mm Hg between the left ventricle and aorta, with either an axial or a centrifugal blood pump, a total cardiac output close to the physiological cardiac demand was achieved, irrespective of the heart condition. The simulations of the transitions between different levels of exercise indicate that with the same reference differential pressure, the proposed approach leads to rapid adaptation of the total cardiac output to physiological levels, while avoiding suction. Comparison with the traditional control strategy of maintaining a reference rotational speed (rpm) of the pump indicates that though the traditional approach has some degree of adaptability, it is only adequate over a narrow range of cardiac demand and clinical conditions of the patient. Our results indicate that the proposed approach is superior to the alternatives in providing an adequate and autonomous adaptation of the total cardiac output over a broad range of exercise conditions (expected when an assist device is used as a destination therapy) and clinical statuses of the native heart (such as further deterioration or recovery of cardiac function), while having the potential to improve the quality of life of patients by reducing the need for monitoring and frequent human intervention. The proposed approach can be clinically implemented using simple controllers, and requires the implantation of two pressure sensors, or estimation of the pressure difference based on other available measurements.

Similar Papers
  • Research Article
  • Citations7

Extracorporeal Membrane Oxygenation for End-Stage Interstitial Lung Disease With Secondary Pulmonary Hypertension at Rest and Exercise: Insights From Simulation Modeling.

  • Mar 01, 2018
  • ASAIO journal (American Society for Artificial Internal Organs : 1992)
  • Scott Chicotka +3
  • Research Article
  • Citations43

Computational Fluid Dynamics Analysis of the Pediatric Tiny Centrifugal Blood Pump (TinyPump)

  • May 01, 2006
  • Artificial Organs
  • Kazuyuki Kido +8
  • Research Article
  • Citations21

Flow characteristics and required control algorithm of an implantable centrifugal left ventricular assist device.

  • Mar 01, 1997
  • Heart and vessels
  • Yoshiyuki Takami +8
  • Research Article

Circulation: Cardiovascular Interventions Editors’ Picks

  • Dec 01, 2012
  • Circulation: Cardiovascular Interventions
  • The Editors
  • Research Article
  • Citations8

Effect of the Center Post Establishment and Its Design Variations on the Performance of a Centrifugal Rotary Blood Pump

  • May 14, 2020
  • Cardiovascular Engineering and Technology
  • Peng Fang +2
  • Research Article

Advancement of the Dragon Heart 7-Series for Pediatric Patients With Heart Failure.

  • Jan 10, 2025
  • Artificial organs
  • Giselle C Matlis +7
  • Research Article
  • Citations7

Indications for rotary blood pumps in clinical practice.

  • May 01, 2001
  • Artificial organs
  • B Meyns
  • Research Article
  • Citations19

A New Technique to Control Brushless Motor for Blood Pump Application

  • Mar 27, 2008
  • Artificial Organs
  • Jeison Fonseca +6
  • PDF
  • Research Article
  • Citations8

Comparative analysis of cardiac mechano-energetics in isolated hearts supported by pulsatile or rotary blood pumps

  • Dec 01, 2019
  • Scientific Reports
  • Marcus Granegger +8
  • Research Article
  • Citations6

Hydrodynamic design and performance analysis of a centrifugal blood pump for cardiopulmonary circulation

  • Nov 01, 2005
  • Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
  • H W Oh +4
  • Research Article

PRELIMINARY ANIMAL STUDY OF A CENTRIFUGAL BLOOD PUMP WITH DESIGN OPTIMIZATION OF ITS IMPELLER AND VOLUTE CASING

  • Mar 01, 2004
  • ASAIO Journal
  • S Y Park +8
  • Research Article
  • Citations1

Structure Design and Flow Field Simulation of Magnetic Liquid Suspension Centrifugal Blood Pump

  • Aug 01, 2014
  • Applied Mechanics and Materials
  • Hua Chun Wu +3
  • Research Article
  • Citations7

Turbulent flow field in maglev centrifugal blood pumps of CH-VAD and HeartMate III: secondary flow and its effects on pump performance.

  • May 31, 2024
  • Biomechanics and modeling in mechanobiology
  • Peng Wu +3
  • Research Article
  • Citations1

Characteristics and hemolysis analysis of centrifugal blood pumps under different speed modulations.

  • Apr 25, 2025
  • Frontiers in physiology
  • Chengxuan Su +4
  • Abstract
  • Citations1

A Novel Rotary Blood Pump for HFpEF

  • Mar 15, 2019
  • The Journal of Heart and Lung Transplantation
  • E Gude +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.