• Home
  • Search
  • Correlation between ocular pulse amplitude measured by dynamic contour tonometer and visual field defects
  • Cite Icon45
  • https://doi.org/10.1007/s00417-007-0706-2Copy DOI Icon

Correlation between ocular pulse amplitude measured by dynamic contour tonometer and visual field defects

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

To investigate the correlation between ocular pulse amplitude and visual field defects in patients with glaucoma, ocular hypertension, and glaucoma suspicion when measured with the Pascal Dynamic Contour Tonometer, and to verify if the ocular pulse amplitude is an independent predictor for visual field parameters. Seventy-seven eyes (42 patients) with glaucoma, ocular hypertension or glaucoma suspicion were examined. Ocular pulse amplitude was measured with the dynamic contour tonometer by one investigator masked to the visual field data. Visual fields were performed within three months of ocular pulse amplitude measurement by the Octopus or Humphrey Field Analyser, and were analysed with Peridata Software. Mean defect, pattern standard deviation ( radical Loss Variance) and regression analysis of those parameters (Trend Indices) were correlated with the ocular pulse amplitude for each eye. Forty-nine eyes had glaucoma, 14 had ocular hypertension, and 14 were glaucoma suspects. The mean follow-up was 46.5 (range 6-96) months. There was a significant correlation between OPA and MD and OPA and PSD, even after correction for IOP (and diagnostic group and eye): the estimated slope equals 2.68 (S.E. = 0.82, p = 0.003) and -0.86 (S.E. = 0.33, p = 0.014), respectively. There was even a weak correlation between OPA and the evolution of MD (dB/year). The slope estimate for OPA equals 0.070 (S.E. = 0.033), p = 0.037. However, after correction for IOP (and diagnostic group and eye), the strength of the relationship is reduced and the evidence disappears: the slope estimate for OPA now equals 0.039 (S.E. = 0.041), p = 0.34. There is no evidence for an association between OPA and the evolution of Trend-PSD. A small ocular pulse amplitude, as measured with a dynamic contour tonometer, is correlated with moderate to severe glaucomatous visual field loss and might be a risk factor for the development of glaucomatous visual field defects.

Similar Papers
  • Research Article
  • Citations36

Physiological diurnal variability and characteristics of the ocular pulse amplitude (OPA) with the dynamic contour tonometer (DCT-Pascal®)

  • Oct 23, 2007
  • International Ophthalmology
  • Sayeh Pourjavan +3
  • PDF
  • Research Article
  • Citations4

Estimating pulsatile ocular blood volume from intraocular pressure, ocular pulse amplitude, and axial length

  • Mar 23, 2023
  • PLOS ONE
  • Ryan H Somogye +5
  • Research Article

The comparison of the quality score of IOP and ocular pulse amplitude (OPA) values measured by dynamic contour tonometer

  • Sep 01, 2007
  • Acta Ophthalmologica Scandinavica
  • P Boghossian +3
  • Research Article
  • Citations9

The effect of intravitreal bevacizumab (Avastin®) on ocular pulse amplitude in neovascular age-related macular degeneration

  • Jan 01, 2011
  • Clinical Ophthalmology (Auckland, N.Z.)
  • Ehud Rechtman +6
  • Research Article
  • Citations19

Ocular Pulse Amplitude in Patients with Asymmetric Primary Open-Angle Glaucoma

  • Jul 22, 2011
  • Current Eye Research
  • Marcelo Jarczun Kac +5
  • Research Article

Comparison of peripapillary atrophy in eyes with unilateral visual field defect in patients with primary open-angle glaucoma and normal tension glaucoma

  • Sep 01, 2007
  • Chinese journal of ophthalmology
  • Yingzi Pan +3
  • Research Article
  • Citations32

Effects of body mass index on intraocular pressure and ocular pulse amplitude

  • Aug 10, 2014
  • Chinese Journal of Practical Ophthalmology
  • Meihong Zhu +4
  • Research Article

Intraocular pressure after cataract surgery measured with Pascal Dynamic Contour Tonometer, Goldmann Applanation Tonometer and Pneumotonometer

  • Sep 01, 2011
  • Acta Ophthalmologica
  • I Villafruela +6
  • Research Article
  • Citations34

Motion automated perimetry identifies early glaucomatous field defects.

  • Sep 01, 1998
  • Archives of Ophthalmology
  • Charles F Bosworth
  • Research Article

Diurnal variation curve of intraocular pressure and ocular pulse amplitude with dynamic contour tonometer in primary open-angle glaucoma and normal tension glaucoma patients

  • Jan 01, 2006
  • National Medical Journal of China
  • Jin-Song Yuan +4
  • Research Article
  • Citations7

Ocular Biomechanical Responses to Long-Duration Spaceflight.

  • Jan 01, 2025
  • IEEE open journal of engineering in medicine and biology
  • Marisse Masis Solano +3
  • Research Article
  • Citations5

Macular Pigment Optical Density and Ocular Pulse Amplitude in Subjects with Different Axial Lengths and Refractive Errors

  • Jun 13, 2015
  • Medical Science Monitor : International Medical Journal of Experimental and Clinical Research
  • Damian Czepita
  • Research Article
  • Citations12

Correlation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes

  • Jan 01, 2013
  • Clinical Ophthalmology (Auckland, N.Z.)
  • Bruno Figueiredo +2
  • Research Article
  • Citations65

Changes in intraocular pressure and ocular pulse amplitude with accommodation

  • Oct 12, 2009
  • British Journal of Ophthalmology
  • S A Read +6
  • Research Article

Diagnostic accuracy of the TsiogkaSpaeth grid test for detecting visual field defects in patients with glaucoma

  • Apr 01, 2025
  • BMJ Open Ophthalmology
  • Anastasia Tsiogka +8
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.