• Home
  • Search
  • Crystal Identification In Modular Array Detectors For High Spatial Resolution PET
  • Cite Icon3
  • https://doi.org/10.1117/12.966704Copy DOI Icon

Crystal Identification In Modular Array Detectors For High Spatial Resolution PET

  • Abstract
  • Literature Map
  • Citations
  • Similar Papers
Abstract

The use of detector arrays in PET has been proposed and studied as a economical means of obtaining very high resolution images. The properties of detector arrays for use in high resolution PET scanners were investigated. Analytical approximations and Monte Carlo simulations were used to design detector arrays consisting of six to eight crystals coupled to two photomultipliers to allow identification of the individual crystals. Arrays of 2.85 mm thick crystals of Bismuth Germanate (BGO), Gadolinium Orthosilicate (GSO), and Barium Fluoride (BaF2) were examined. The effect of interdetector materials such as lead, and plastic on positioning accuracy was tested. Assembled arrays of six 2.85 mm thick BG0 crystals yielded line spread function FWHMs of 2.4 to 3.2 millimeters. The limiting resolution of detector arrays was found to be defined by the scintillation light yield of the crystals, the light gathering efficiency of the detector arrays, and the fraction of interdetector scatter.

Similar Papers
  • Conference Article

Enhanced resolution folded architecture spectral detector for fiber optic sensors

  • Jun 09, 2004
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Kenith E Meissner +3
  • Research Article
  • Citations7

A simulation study for estimating scatter fraction in whole-body 18F-FDG PET/CT.

  • Dec 28, 2016
  • Radiological Physics and Technology
  • Shota Hosokawa +7
  • Research Article
  • Citations25

Optimizing the use of detector arrays for measuring intensity correlations of photon pairs

  • Jul 11, 2013
  • Physical Review A
  • Daniel S Tasca +4
  • Conference Article
  • Citations1

Depth-of-interaction Reconstruction in NeuroEXPLORER

  • Oct 16, 2021
  • Tao Feng +3
  • Research Article
  • Citations6

Fabrication of silicon bolometers with bulk micromachining technology

  • Dec 20, 2003
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • A Faes +3
  • Research Article
  • Citations2

Feasibility of local power losses determination in the TJ-II heliac using movable bolometers

  • Apr 01, 1989
  • IEEE Transactions on Plasma Science
  • M.A Ochando +2
  • Research Article
  • Citations28

Impact of System Design Parameters on Image Figures of Merit for a Mouse PET Scanner

  • Feb 01, 2004
  • IEEE Transactions on Nuclear Science
  • K Lee +4
  • Conference Article
  • Citations5

Assessment Of Scatter In Two PET Scanners With And Without Interplane Septa

  • Oct 22, 1990
  • C Michel +5
  • Conference Article
  • Citations4

Full 3D-OSEM reconstruction with compressed response of the system

  • Oct 16, 2004
  • J Lopez Herraiz +4
  • Conference Article

Dynamic Positron Emission Tomography: Application to Imaging Fluid Mobility in Fractured Cores

  • Nov 11, 2013
  • Marko Maucec +6
  • Conference Article
  • Citations2

GATE simulations of human and small animal PET for determination of scatter fraction as a function of object size

  • Oct 01, 2009
  • A Konik +2
  • Research Article
  • Citations26

Calibration procedure for a DOI detector of high resolution PET through a Gaussian mixture model

  • Oct 01, 2004
  • IEEE Transactions on Nuclear Science
  • E Yoshida +3
  • Conference Article
  • Citations2

Monte Carlo investigation of scatter in dual head coincidence imaging

  • Oct 15, 2000
  • B.W Pointon +1
  • Research Article
  • Citations8

Surface dosimetry in a CT scanner using MOSFET detectors and Monte Carlo simulations

  • Feb 01, 2008
  • Journal of Physics: Conference Series
  • F Verhaegen +3
  • Research Article
  • Citations16

Scatter Characterization and Correction for Simultaneous Multiple Small-Animal PET Imaging

  • Aug 29, 2013
  • Molecular Imaging and Biology
  • Rameshwar Prasad +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.