Abstract

A statistical study of dc vacuum arc extinction in a vacuum interrupter (VI) with transverse axisymmetric magnetic field has been carried out at various external circuit parameters. The relationship between the maximum current that a VI can switch off and the magnetic field, the circuit inductance, and the VI shunt capacitance has been found. A statistical study has allowed us to define this maximum switched-off current with specified probability of failure. The possible causes of a VI failure are discussed.

Similar Papers
  • Conference Article
  • Citations1

DC vacuum arc extinction in a transverse axisymmetric magnetic field

  • Sep 01, 2008
  • D Alferov +2
  • Research Article
  • Citations16

Two-Dimensional Observation of Copper Atoms After Forced Extinction of Vacuum Arcs by Laser-Induced Fluorescence

  • Jul 17, 2020
  • IEEE Transactions on Plasma Science
  • Zhenxing Wang +7
  • Research Article
  • Citations4

Transferred charge: indicator for vacuum applicability

  • Oct 01, 2017
  • CIRED - Open Access Proceedings Journal
  • Martin Leusenkamp +1
  • Conference Article
  • Citations1

Investigation of ramp rate of electric and magnetic field on magnetron pressure measurements of vacuum interrupters

  • Oct 23, 2022
  • Tushar Damle +3
  • Conference Article
  • Citations2

Performance of vacuum interrupters in electrical power systems with an effectively earthed neutral

  • Sep 01, 2016
  • Erik D Taylor +3
  • Conference Article
  • Citations11

Welding behavior of vacuum interrupters equipped with CuCr contact material caused by making and breaking operations under short circuit current interruption

  • Sep 01, 2012
  • Dietmar Gentsch +1
  • Conference Article

Research on current breaking and carrying property of cup shaped and horseshoe axial magnetic electrode in vacuum interrupter

  • Oct 01, 2017
  • Dongli Bi +4
  • Research Article

KTX-이음 철도차량용 진공인터럽터 축자계 전극의 설계 및 검증

  • May 31, 2023
  • The transactions of The Korean Institute of Electrical Engineers
  • Tae-Hoon Lee +3
  • Research Article
  • Citations25

The irreversibility of dielectric strength of vacuum interrupters after short-circuit current interruption

  • Jul 01, 1991
  • IEEE Transactions on Power Delivery
  • P Osmokrovic
  • Research Article
  • Citations13

Improvement of charged particles transport across a transverse magnetic filter field by electrostatic trapping of magnetized electrons

  • Jul 01, 2014
  • Physics of Plasmas
  • B K Das +3
  • Research Article
  • Citations19

Optimization of Three-Dimensional Magnetic Field in Vacuum Interrupter Using Particle Swarm Optimization Algorithm

  • Nov 01, 2021
  • IEEE Transactions on Applied Superconductivity
  • Peiyuan Li +5
  • Research Article
  • Citations22

Better Interpretation of Vacuum Interrupter Test

  • Mar 01, 1999
  • IEEE Industry Applications Magazine
  • M B Schulman +1
  • Conference Article
  • Citations7

An influence of an ambient magnetic field induced by a nearby parallel conductor on high-current vacuum arcs

  • Sep 01, 2012
  • Xiaofei Yao +4
  • Conference Article
  • Citations1

Model for the welding of axial magnetic field vacuum interrupter contacts

  • Sep 01, 2016
  • Erik D Taylor +2
  • Research Article
  • Citations7

Thermocapillary flow and free-surface deformation of liquid bridge under different magnetic fields

  • Feb 14, 2018
  • Applied Thermal Engineering
  • Hulin Huang +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.