Abstract

Quality assessment of medical images is essential for complete automation of image processing pipelines. For large population studies such as the UK Biobank, artefacts such as those caused by heart motion are problematic and manual identification is tedious and time-consuming. Therefore, there is an urgent need for automatic image quality assessment techniques. In this paper, we propose a method to automatically detect the presence of motion-related artefacts in cardiac magnetic resonance (CMR) images. As this is a highly imbalanced classification problem (due to the high number of good quality images compared to the low number of images with motion artefacts), we propose a novel k-space based training data augmentation approach in order to address this problem. Our method is based on 3D spatio-temporal Convolutional Neural Networks, and is able to detect 2D+time short axis images with motion artefacts in less than 1 ms. We test our algorithm on a subset of the UK Biobank dataset consisting of 3465 CMR images and achieve not only high accuracy in detection of motion artefacts, but also high precision and recall. We compare our approach to a range of state-of-the-art quality assessment methods.

Similar Papers
  • Research Article
  • Citations115

Automatic CNN-based detection of cardiac MR motion artefacts using k-space data augmentation and curriculum learning.

  • Apr 22, 2019
  • Medical image analysis
  • Ilkay Oksuz +10
  • Research Article
  • Citations38

Positive effect on patient experience of video information given prior to cardiovascular magnetic resonance imaging: A clinical trial.

  • Feb 22, 2018
  • Journal of clinical nursing
  • Britt-Marie Ahlander +3
  • Research Article
  • Citations12

New Frontiers in the Evaluation of Cardiac Patients for Noncardiac Surgery

  • Dec 01, 2007
  • Anesthesiology
  • Ronit Lavi +4
  • Conference Article
  • Citations4

Uno-Qa: an Unsupervised Anomaly-Aware Framework with Test-Time Clustering for Octa Image Quality Assessment

  • Apr 18, 2023
  • Juntao Chen +4
  • Research Article
  • Citations16

An optimized CNN-based quality assessment model for screen content image

  • Feb 06, 2021
  • Signal Processing: Image Communication
  • Xuhao Jiang +4
  • Book Chapter
  • Citations2

Detection of Motion Artifacts in Photoplethysmographic Signals: Algorithms Comparison

  • Jan 01, 2014
  • R Couceiro +5
  • Research Article
  • Citations17

Effects of High-Resolution CT of the Lung Using Partial Versus Full Reconstruction on Motion Artifacts and Image Noise

  • Sep 01, 2006
  • American Journal of Roentgenology
  • Hong Il Ha +4
  • Research Article

Highlights From the Circulation Family of Journals.

  • Sep 04, 2018
  • Circulation
  • PDF
  • Abstract
  • Citations1

Reproducibility of area at risk assessment in acute myocardial infarction by T1- and T2-mapping sequences in cardiac magnetic resonance imaging in comparison to Tc99m-Sestamibi SPECT

  • Jan 01, 2013
  • Journal of Cardiovascular Magnetic Resonance
  • Birgit Langhans +4
  • Research Article
  • Citations4

Optimization of activity-driven event detection for long-term ambulatory urodynamics.

  • Jun 01, 2024
  • Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine
  • Farhath Zareen +7
  • Research Article

Asymmetric two-stream network for screen content image quality assessment based on region features

  • Jan 11, 2022
  • Journal of Electronic Imaging
  • Lili Shen +3
  • Conference Article
  • Citations7

Quality assessment for out-of-focus blurred images

  • Dec 01, 2015
  • Yutao Liu +3
  • Conference Article
  • Citations8

Quality assessment of multi-view-plus-depth images

  • Jul 01, 2017
  • Jiheng Wang +3
  • PDF
  • Research Article
  • Citations29

Magnetic Resonance Image Quality Assessment by Using Non-Maximum Suppression and Entropy Analysis.

  • Feb 16, 2020
  • Entropy (Basel, Switzerland)
  • Rafał Obuchowicz +4
  • PDF
  • Research Article
  • Citations33

Automatic Assessment of Full Left Ventricular Coverage in Cardiac Cine Magnetic Resonance Imaging with Fisher Discriminative 3D CNN.

  • Nov 21, 2018
  • IEEE Transactions on Biomedical Engineering
  • Le Zhang +7
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.