Tuned liquid column gas dampers (TLCGD) show excellent energy and vibration absorbing capabilities appropriate for earthquake engineering. The objective of this work is to introduce a new concept of coupled tuned liquid column gas dampers which allow an extended field of applications. In the proposed configuration, several absorbers are connected in a spatial chain generating a multi-degree of freedom damper system which can be tuned to a selected number of structural modes. Because all absorbers vibrate at different natural frequencies simultaneously, the proposed design represents an improvement over conventional TLCGD which can only be tuned to a single structural mode. Another benefit of multi-mode tuning is the significant increase in active liquid mass compared to other damping devices. For a most effective vibration reduction, a numerical tuning process in state space will deliver the free system natural frequency and damping ratio of all absorbers. The capabilities of the new damping device are demonstrated on a simple laboratory structure that is investigated numerically and experimentally. The results illustrate the excellent energy dissipating properties of the proposed setup and emphasize the adequacy of coupled TLGCD for base-isolated structures. A notable benefit of such types of dampers lies in their lack of moving mechanical parts, their cheap and easy implementation into civil engineering structures and low maintenance costs. Possible modifications with respect to natural frequency and even of the damping properties can be performed with little additional expenses, and the additional weight due to the liquid mass may be used as a possible reservoir, e.g., for fire fighting. Apart from that, they exhibit a performance that is comparable to tuned mass dampers.

Loading PDF

Similar Papers
  • Research Article
  • Citations32

Control of wind/wave-induced vibrations of jacket-type offshore wind turbines through tuned liquid column gas dampers

  • Feb 17, 2015
  • Structure and Infrastructure Engineering
  • Reza Dezvareh +2
  • Research Article
  • Citations8

Damping Of Pedestrian‐Induced Bridge Vibrations By Tuned Liquid Column Dampers

  • Nov 24, 2004
  • PAMM
  • Michael Reiterer +1
  • Research Article
  • Citations4

Hydrodynamic characteristics and application of tuned liquid dampers with internal damping devices

  • Jun 08, 2022
  • The Structural Design of Tall and Special Buildings
  • Lanfang Zhang +2
  • Research Article
  • Citations1

Modal Research of Underground Arch Structure With Elastic Support

  • Jul 01, 2021
  • Journal of Physics: Conference Series
  • Chen Zhuo +2
  • Research Article
  • Citations11

Semi-active omnidirectional liquid column vibration absorber with rapid frequency adjustment capability

  • Nov 06, 2024
  • Mechanical Systems and Signal Processing
  • Behnam Mehrkian +1
  • Research Article
  • Citations15

Development and evaluation of an MRE-based absorber with two individually controllable natural frequencies

  • Jul 31, 2018
  • Smart Materials and Structures
  • J Yang +7
  • Conference Article
  • Citations12

The TLCD Passive Control: Numerical Investigations vs. Experimental Results

  • Nov 09, 2012
  • Alberto Di Matteo +3
  • Conference Article

Study on Mitigation of Sliding Motion of Cask-Canister Coupled System Subjected to Seismic Excitation Using Highly Viscous Fluid

  • Jul 17, 2022
  • Atsuhiko Shintani +2
  • Research Article
  • Citations59

Modeling and experimental validation of a new type of tuned liquid damper

  • Jan 16, 2016
  • Acta Mechanica
  • Rafael O Ruiz +2
  • Research Article
  • Citations7

Generalization of the Wittrick-Williams formula for counting modes of flexible structures

  • Nov 01, 1995
  • Journal of Guidance, Control, and Dynamics
  • A V Balakrishnan
  • Conference Article
  • Citations4

An investigation on a semi-active magnetorheological tuned liquid column damper (MR-TLCD)

  • Apr 15, 2016
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • H X Sun +1
  • PDF
  • Research Article
  • Citations8

A Novel Single Tube Semi-Active Tuned Liquid Gas Damper for Suppressing Horizontal Vibrations of Tower-like Structures

  • Mar 24, 2022
  • Applied Sciences
  • Michael Reiterer +1
  • Preprint Article

Using Rotational Motions to understand material damage in Civil Engineering structure

  • May 15, 2023
  • Anjali Dhabu +5
  • Conference Article
  • Citations1

Generalized Model for the Approximation of Coupled Acousto-Mechanical Natural Frequencies in High-Pressure Centrifugal Compressors

  • Sep 21, 2020
  • Christoph Rocky Heinrich +3
  • Research Article
  • Citations4

Energy absorption properties of origami‐based re‐entrant honeycomb sandwich structures with CFRP subjected to low‐velocity impact

  • Sep 15, 2024
  • Polymer Composites
  • Zhen Cui +6
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.