• Home
  • Search
  • Detection of triazophos using quartz crystal microbalance (QCM) immunosensor
  • https://doi.org/10.13031/2013.24790Copy DOI Icon

Detection of triazophos using quartz crystal microbalance (QCM) immunosensor

Show More
  • Abstract
  • Literature Map
  • Similar Papers
Abstract

Quartz crystal microbalance (QCM) immunosensors are based on the principle that adsorption of substances on the surface of a quartz crystal changes its resonance oscillation frequency. A QCM immunosensor was developed for the detection of triazophos by pre-coating the QCMs with toxin-specific antibodies. The antibodies immobilization technique uses selfassembly monolayer(SAM) with 3-Mercaptopropionic acid (MPA), and the QCM detection method uses dip and dry application. Upon binding of pesticide in purified form with the immobilised triazophos antibodies, the increase in mass at the QCM surface resulted in a reduction in the frequency of resonance oscillation in a manner dependent upon the amount of pesticide bound. The QCM was able to detect as low as 1 ng pesticide. This detection sensitivity is comparable to enzyme linked immunosorbent assay (ELISA) but the assay is faster. This immunoassay was shown to be specific, sensitive, rapid and economical, thus providing a viable alternative to pesticide detection methods.

Similar Papers
  • Research Article
  • Citations3

A Novel Method for Determination of Cattle Bovine Ephemeral Fever Virus in Liquid with Quartz Crystal Microbalance Immunosensor

  • Jan 01, 2005
  • Analytical Letters
  • Yuan‐Guey Lee +2
  • Research Article
  • Citations71

Evaluation of a high-affinity QCM immunosensor using antibody fragmentation and 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer

  • Jul 28, 2004
  • Biosensors and Bioelectronics
  • Shigeru Kurosawa +5
  • PDF
  • Research Article
  • Citations14

Detection of Cartilage Oligomeric Matrix Protein Using a Quartz Crystal Microbalance

  • Dec 20, 2010
  • Sensors (Basel, Switzerland)
  • Shih-Han Wang +10
  • Research Article
  • Citations24

Conventional detection method of fibrinogen and fibrin degradation products using latex piezoelectric immunoassay

  • Apr 12, 2003
  • Biosensors and Bioelectronics
  • Hidenobu Aizawa +5
  • Research Article
  • Citations47

Quartz crystal microbalance immunosensor for highly sensitive 2,3,7,8-tetrachlorodibenzo-p-dioxin detection in fly ash from municipal solid waste incinerators

  • Jan 01, 2005
  • The Analyst
  • Shigeru Kurosawa +2
  • Research Article
  • Citations1

Characterization of self-assembled monolayers (SAM) of peptide mimotopes of CD20 antigen and their binding with rituximab (R) using Quartz Crystal Microbalance (QCM) Piezo-Immunosensors: A novel technique to study CD20 antigen interaction.

  • May 20, 2016
  • Journal of Clinical Oncology
  • Mohammad Muhsin Chisti +5
  • Research Article
  • Citations2

USE QCM TO MEASURE SELF-ASSEMBLING MONOLAYER, PLASMA MODIFICATION, AND SURFACE GRAFT POLYMERIZATION

  • Dec 01, 2009
  • Biomedical Engineering: Applications, Basis and Communications
  • Ko-Shao Chen +3
  • Research Article
  • Citations18

Quartz crystal microbalance cardiac Troponin I immunosensors employing signal amplification with TiO2 nanoparticle photocatalyst

  • Feb 19, 2021
  • Talanta
  • Ji Yoon Lim +1
  • Research Article
  • Citations68

Amplification of the antigen–antibody interaction from quartz crystal microbalance immunosensors via back-filling immobilization of nanogold on biorecognition surface

  • Sep 20, 2006
  • Journal of Immunological Methods
  • Dian-Quan Tang +3
  • Research Article
  • Citations96

Temperature-Induced Apparent Mass Changes Observed during Quartz Crystal Microbalance Measurements of Atomic Layer Deposition

  • Aug 23, 2003
  • Analytical Chemistry
  • M N Rocklein +1
  • Research Article
  • Citations1

Investigation of the influence of the geometric parameters of AFM cantilevers on the resonant frequency of their oscillations

  • Dec 01, 2020
  • Journal of Physics: Conference Series
  • I V Panchenko +5
  • Research Article
  • Citations21

Dioxin immunosensor using anti-2,3,7,8-TCDD antibody which was produced with mono 6-(2,3,6,7-tetrachloroxanthene-9-ylidene) hexyl succinate as a hapten

  • Jun 08, 2006
  • Biosensors and Bioelectronics
  • Jong-Won Park +7
  • Research Article
  • Citations14

High-Frequency Wireless and Electrodeless Quartz Crystal Microbalance Developed as Immunosensor

  • Jul 01, 2007
  • Japanese Journal of Applied Physics
  • Hirotsugu Ogi +5
  • Research Article
  • Citations24

A novel technique to immobilize DNA on surface of a quartz crystal microbalance by plasma treatment and graft polymerization

  • Sep 14, 2006
  • Materials Science and Engineering: C
  • Ko-Shao Chen +4
  • Research Article
  • Citations30

Sensing Escherichia coli O157:H7 via frequency shift through a self-assembled monolayer based QCM immunosensor

  • Feb 01, 2008
  • Journal of Zhejiang University SCIENCE B
  • Li-Jiang Wang +5
Cactus Communications logo