- Research Article
85
- 10.1016/0016-2361(84)90327-2
Release of volatiles from large coal particles in a hot fluidized bed
- Jul 01, 1984
- Fuel
- John F Stubington + 1 more +1
Release of volatiles from large coal particles in a hot fluidized bed
A new method to measure apparent reactivity, which accounts for all the effects of coal type on reaction kinetics in fluidized bed combustion (FBC), has been developed to characterize and rank various coals according to overall burning rates in a fluidized bed environment. This method estimates FBC reactivity by means of a parameter called mean carbon conversion time, which can be related to the carbon inventory of practical FBC systems. An easy and rapid experimental technique, which burns coal batchwise in a bench-scale fluidized bed combustor, has been developed to determine the mean carbon conversion time. This technique was employed to examine five different coals and rank them according to FBC reactivity. To differentiate between devolatilization and char combustion, a turning point on the experimental burning rate curve was used instead of the common method of observing the volatile flame. Char mean carbon conversion times were also measured and compared. The effects of coal particle size and bed temperature on FBC reactivity and combustion efficiency and the effects of particle fragmentation on experimental results were investigated. Efforts were made to correlate the FBC reactivity with other coal parameters such as volatile content, carbon content and free swelling index.
Release of volatiles from large coal particles in a hot fluidized bed
Release of volatiles from large coal particles in a hot fluidized bed
A model of coal combustion dynamics in a fluidized bed combustor
A model of coal combustion dynamics in a fluidized bed combustor
Limiting NO x and SO 2 emissions from an industrial-size fluidised-bed combustor
Limiting NO x and SO 2 emissions from an industrial-size fluidised-bed combustor
Coal combustion characteristics in a fluidized bed combustor with a draft tube
The effects of gas velocity to draft tube (3–6 Um), bed temperature (800–900°C) and excess air ratio (0–30%) on the total entrainment rate, overall combustion efficiency and heat transfer coefficient have been determined in an internally circulating fluidized bed combustor with a draft tube. The total entrainment rate increases with an increase in gas velocity to draft tube, but decreases with increasing bed temperature and excess air ratio. The overall combustion efficiency increases with increasing excess air ratio, but decreases with increasing gas velocity to draft tube. The overall combustion efficiency obtained in internally circulating fluidized beds was found to be somewhat higher than that in a bubbling fluidized bed combustor.
Read moreSupport studies in fluidized-bed combustion. Quarterly report, October--December 1978
These studies support the development program in atmospheric and pressurized fluidized-bed coal combustion. Laboratory and process development-scale studies are aimed at providing information on limestone utilization, control of the emission of alkali metal compounds and SO/sub 2/ during combustion, particulate loading in flue gas, and other aspects of fluidized-bed coal combustion. This report presents information on the effect of bed temperature, superficial gas velocity and gas hourly space velocity on the removal of gaseous NaCl from hot gas streams by a granular bed of diatomaceous earth; results of experiments in which the adsorption capacity for gaseous NaCl of activated bauxite was measured after regeneration by an aqueous leaching process; and an estimate of the cost of using these two sorbents for alkali metal control in a large PFBC. Results are also presented for studies aimed at the development of an acoustic dust conditioning system, and the evaluation of a high-efficiency cylone for removal of particles from a high-pressure, high-temperature gas stream. The relationship of the SO/sub 2/ reactivity of limestones to internal surface area, pore diameter, and pore volume are examined.
Read moreSupport studies in fluidized-bed combustion. Quarterly report, January-March 1979
This work supports the development studies for atmospheric and pressurized fluidized-bed coal combustion. Laboratory and process development studies are aimed at providing needed information on limestone utilization, control of emission of alkali metal compounds and SO/sub 2/, particulate loadings of flue gas, and other aspects of fluidized-bed coal combustion. This report presents information on: the removal of gaseous alkali metal compounds from hot flue gas using granular sorbents, results of tests of the efficiency of a commercial high-efficiency cyclone (TAN-JET), information on particulate emissions from FBCs, and the effect of CaCl/sub 2/ and Na/sub 2/CO/sub 3/ on the sulfation of limestone.
Read moreThe Influence of Volatiles on Combustion Rate of Loy Yang Coal Char in a Fluidised Bed Combustor
An experimental investigation into the influence of volatiles as simulated by propane on the combustion rate of Loy Yang coal char in a bubbling fluidised bed combustor has been conducted. The weight loss and burn‐out times for a batch of +3.35‐3.175 mm sized coal particles were examined at temperatures of 700°C, 800°C and 900° C. Silica sand (+250–180μm) as the bed material was fluidised either by a 10% v/v oxygen stream or 10% v/v oxygen and 3% v/v propane mixture, both balanced with nitrogen. Samples were retrieved at various time increments by means of a movable gauze basket and quenched in a nitrogen stream. It was observed that burnout times of char particles at 700°C, 800°C and 900°C in a propane/air environment were 13%, 39% and 88% greater respectively, than those at the same temperatures but in the 10% v/v oxygen stream. At the lower combustion temperature of 70O°C, minimal effect of extended char combustion times is concordant with observations of particles spending a small proportion of time at the bed surface, where oxygen concentration is lower due to over‐bed burning of propane. At the higher bed temperatures, the reduction in the char combustion rate in the presence of propane is consistent with the transition from over‐bed to in‐bed combustion of propane. Consequently, there is competition between the propane and char for available oxygen, causing a substantial decrease in the char combustion rate with increasing temperature. The influence of propane on the burnout times observed compare favourably to that reported in literature. The rate of char combustion was found to correlate well to the simple diffusion‐controlled oxidation of a char particle in laminar flow.
Read moreExperiment and grey relational analysis of seaweed particle combustion in a fluidized bed
Experiment and grey relational analysis of seaweed particle combustion in a fluidized bed
Rank dependence of N 2O emission in fluidized-bed combustion of coal
Rank dependence of N 2O emission in fluidized-bed combustion of coal
The influence of transport phenomena on the fluidized bed combustion of a single carbon particle
The influence of transport phenomena on the fluidized bed combustion of a single carbon particle
Relative roles of chemical and mass transfer rate control in fluidized-bed combustion of coal chars
Relative roles of chemical and mass transfer rate control in fluidized-bed combustion of coal chars
Selecting fines recycle methods to optimize fluid bed combustor performance
Testing and analysis of a number of different fines recycle methods for fluid bed combustors has led to a generalized modeling technique. This model accounts for the effect of pertinent variables in determining overall combustion efficiencies. Computer application of this model has allowed trade-off studies to be performed that show the overall process effects of changes in individual operating parameters. Verification of the model has been accomplished in processing campaigns while combusting fuels such as graphite and bituminous coal. A 0.4 MW test unit was used for the graphite experimental work. Solid fuel was typically crushed to 5 mm maximum screen size. Bed temperatures were normally controlled at 900/sup 0/C; the combustor was an atmospheric unit with maximum in-bed pressures of 0.2 atm. Expanded bed depths ranged from 1.5 to 3 meters. Additional data was taken from recycle tests sponsored by EPRI on the B and W 6 ft x 6 ft fluid bed combustor. These tests used high sulfur coal in a 1.2 meter deep, 850/sup 0/C atmospheric fluidized bed of limestone, with low recycle rates and temperatures. Close agreement between the model and test data has been noted, with combustion efficiency predictions matching experimental results within 1%.
Read moreEnhanced combustion behavior and NOx reduction performance in a CFB combustor by combining flue gas recirculation with air-staging: Effect of injection position
Enhanced combustion behavior and NOx reduction performance in a CFB combustor by combining flue gas recirculation with air-staging: Effect of injection position
Read moreEmission Characteristics of Heavy Metals and Organic Pollutants from the Combustion of Sewage Sludge in a Fluidized Bed Combustor
In this study, a bench-scale fluidized bed combustor (FBC) was used to investigate the partitioning of nine heavy metals (Cd, Co, Cr, Cu, Mn, Ni, Pb, V, and Zn) and organic hazardous air pollutants, including aliphatics, monoaromatic compounds, cyclic hydrocarbons, and polycyclic aromatic hydrocarbons (PAHs), in the gas and solid phases of emissions from combustion of seven sewage sludge samples. The concentrations of heavy metals (HMs) in two main ash streams (bottom ash and fly ash) were detected by inductively coupled plasma−optical emission spectroscopy (ICP−OES). It showed that the concentration of zinc was the highest in bottom and fly ashes, ranging from 1600−1900 and 2200−2900 mg/kg, respectively. The average concentrations of HMs analyzed in both bottom ash and fly ash followed the order of Zn > Cu > Mn > Cr > Ni > Pb > V > Cd > Co. Co and Cu were mostly found in bottom ashes, while Pb and Zn were mostly found in fly ashes; other HMs were almost equally distributed between bottom and fly ashes. Organic pollutants [particularly hazardous air pollutants (HAPs)] in flue gas trapped onto the XAD resin and in fly ash were extracted with dichloromethane and analyzed using a gas chromatography−mass spectrometry (GC−MS) analyzer. The results showed that PAHs were more likely emitted in flue gas than in fly ash and the concentrations of PAHs in both flue gas and fly ash of sludge combustion were in a reasonably comparable range, with a maximum concentration reaching 0.03 mg/L. Aliphatics were mainly recovered from fly ashes (>70%), while monoaromatic compounds were found in both flue gases and fly ashes and cyclic hydrocarbons were undetectable for most of the sludge samples. The total amounts of HAPs in the flue gases increased most likely with the increasing H/C ratios of the sludge samples.
Read moreAuthor index
Author index