• Home
  • Search
  • Diagnostic testing of thermally aged medium voltage XLPE cable joints
  • Cite Icon10
  • https://doi.org/10.1109/ceidp.2012.6378727Copy DOI Icon

Diagnostic testing of thermally aged medium voltage XLPE cable joints

  • Oct 1, 2012
  • F Mauseth +2 more
Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Current loading of wind farm distribution network is very different from that observed for traditional underground cable systems. Variations in wind power results in a significant number of current load cycles during service. The current can increase from zero to maximum rated load in a short time. This can cause high temperature gradients in the cable systems inducing significant thermo-mechanical forces during heating and cooling, and thermal oxidation at high load. Several premature service failures of cable joints in wind farm distribution networks have occurred, mainly due to the combined action of bad metallic connectors and high load current. Partial discharge measurements are today performed on-site using different frequencies and magnitudes of the test voltage. As the oxidation process causes the conductivity of the bulk and surfaces of the materials involved to strongly increase, this will also likely impact the frequency dependence of the partial discharges. This work includes laboratory high temperature ageing of rubber type heat-shrink MV XLPE cable joints including temperature gradients by application of high load currents. The ageing has been electrically characterised by variable partial discharge measurements in the frequency range of 10 mHz to 100 Hz up to 12 kV (2 U <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</inf> ). The joint material was examined by microscopy examinations after ageing. The results show that the partial discharges are strongly frequency and voltage dependent. For shorter ageing times of the rubber joints, the number of discharges per voltage cycle decrease to zero for frequencies below 10 Hz. At longer ageing times resulting in severe material ageing, the number of discharges per voltage cycle strongly increases by decreasing frequency. In this case the inception voltage at 0.1 Hz was equal or lower than that measured at higher frequencies. It is observed by SEM that especially the stress-control material was strongly degraded by the high temperature conditions.

Similar Papers
  • Conference Article
  • Citations23

Partial discharge characteristics till breakdown for XLPE cable joint with an artificial defect

  • Jun 01, 2003
  • S Tokunaga +5
  • Conference Article
  • Citations6

A Locating Diagnosis of Partial Discharge on Cross-bonding Ground System

  • May 19, 2021
  • W Inwanna +3
  • Research Article
  • Citations17

Numerical sensor design for partial discharge detection on power cable joint

  • Aug 01, 2015
  • IEEE Transactions on Dielectrics and Electrical Insulation
  • Guo-Ming Ma +5
  • Conference Article
  • Citations11

Electric field distribution in 132 kV one piece premolded cable joint structures

  • Sep 01, 2012
  • H A Illias +5
  • Research Article
  • Citations4

Comparison of On-Line Partial Discharge Detection Techniques for High Voltage Power Cable Joints and Terminations

  • Feb 28, 2023
  • Tanzania Journal of Engineering and Technology
  • Prisca Chambela +1
  • Research Article

An embedded wide-band sensor for PD on-line monitoring of XLPE cable joint

  • Aug 01, 2019
  • Journal of Physics: Conference Series
  • Fangda Fu +5
  • Research Article
  • Citations7

XLPE cable joint defects measurement method based on point cloud remapping

  • Jan 06, 2024
  • Measurement
  • Lei Deng +5
  • Conference Article
  • Citations3

Study on UWB frequency characteristics of partial discharge as a criterion of aging degree of stator winding insulation

  • Jun 21, 2000
  • Song Jiancheng +2
  • Conference Article
  • Citations5

Detection of Partial Discharge and Investigation for AC 22.9kV Power Cable Termination

  • Nov 13, 2022
  • Hyeonseok Lee +5
  • Research Article
  • Citations61

Partial discharge pulse propagation in power cable and partial discharge monitoring system

  • Jun 01, 2014
  • IEEE Transactions on Dielectrics and Electrical Insulation
  • Bojie Sheng +6
  • Conference Article
  • Citations8

Development of partial discharge automated locating system for power cable

  • Oct 25, 1998
  • A Miyazaki +5
  • Conference Article
  • Citations11

Partial discharge characteristics of oil impregnated insulation system with an oil gap under continuous AC voltage application

  • Jun 01, 2014
  • Yuu Iwashita +3
  • Conference Article

Partial Discharge Behavior of Epoxy/paper Insulated Tubular Busbars with Artificial Defects

  • Apr 01, 2019
  • Chuang Zhang +6
  • Conference Article
  • Citations5

Temperature gradient effect on partial discharge activity-modelling and simulation

  • Oct 01, 2012
  • Larisa Mariut
  • Research Article
  • Citations2

Intelligent Detection and Localization of Cable Faults Using Advanced Discharge Analysis Techniques

  • Feb 07, 2025
  • Informatica
  • Yi Wang +4
Cactus Communications logo