Digital control of a single-phase shunt active filter

  • Jun 15, 2003
  • R Grino +2 more
Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Shunt active power filters are proved a useful elements to correct the distorted currents caused by nonlinear loads in power distribution systems. This work presents an all digital approach, based on the repetitive control technique, for their control and a design is performed for the particular case of single-phase shunt active filters with a full-bridge boost topology. Several experimental results are also presented to show the behavior of the closed loop system.

Similar Papers
  • Conference Article
  • Citations89

Modeling and nonlinear control of shunt active power filter in the synchronous reference frame

  • Oct 01, 2000
  • N Mendalek +1
  • Conference Article
  • Citations12

PWM based sliding mode controller for shunt active power filter

  • Jan 01, 2017
  • Minarti Mane +1
  • Research Article
  • Citations2

Performance of automatic gain adjustment in a shunt active filter intended for installation on power distribution systems

  • Jan 16, 2003
  • Electrical Engineering in Japan
  • Pichai Jintakosonwit +3
  • Research Article
  • Citations39

Compensation Characteristics of Shunt Active and Series Active Power Filters.

  • Jan 01, 1993
  • IEEJ Transactions on Industry Applications
  • F.Z Peng +2
  • Research Article
  • Citations11

Current Control of the Isolated Self-Excited Induction Generator using Shunt Active Filter

  • Jan 01, 2012
  • Energy Procedia
  • A.M Bouzid +5
  • Research Article
  • Citations4

Mitigation of Line Current Harmonics Using Shunt Active Filter With Instantaneous Real and Reactive Power Theory

  • Jan 01, 2014
  • IOSR Journal of Electrical and Electronics Engineering
  • M Ramya +3
  • Conference Article
  • Citations12

Takagi-sugeno (TS)-type fuzzy logic controller for three-phase four-wire shunt active power filter for unbalanced load

  • Nov 01, 2016
  • Harsha Vanjani +3
  • Conference Article
  • Citations5

Predictive Control of Seven Level Multi-level Inverter Based Single Phase Shunt Active Filter

  • Oct 09, 2022
  • Parth Patel +4
  • Conference Article
  • Citations5

A repetitive-based control for a single-phase shunt active power filter for harmonic voltage compensation

  • Jun 01, 2016
  • G Brusco +5
  • Research Article
  • Citations126

New digital reference current generation for shunt active power filter under distorted voltage conditions

  • Dec 19, 2008
  • Electric Power Systems Research
  • Mohamed Abdusalam +3
  • Research Article

Unknown input observer-Model predictive control scheme for state and disturbance estimation of shunt active filter

  • Dec 17, 2024
  • International Journal of Computational and Experimental Science and Engineering
  • Nagulapati Kiran +1
  • Book Chapter
  • Citations3

Photovoltaic Cell with Shunt Active Power Filter for Harmonic Cancelation Using Modified PSO-Based PI Controller

  • Jan 01, 2020
  • Amba Subhadarshini Nayak +2
  • Research Article

Adaptive filter based current controller for Shunt Active filter

  • Apr 25, 2018
  • International Journal of Engineering & Technology
  • R Sriranjani +1
  • Conference Article
  • Citations37

Implementation of single-phase synchronous d-q reference frame controller for shunt active filter under distorted voltage condition

  • Dec 01, 2010
  • Vinod Khadkikar +3
  • Research Article
  • Citations49

FLC based shunt active filter (p–q and Id–Iq) control strategies for mitigation of harmonics with different fuzzy MFs using MATLAB and real-time digital simulator

  • Dec 12, 2012
  • International Journal of Electrical Power & Energy Systems
  • Anup Kumar Panda +1