• Home
  • Search
  • Direct 4D PET MLEM reconstruction of parametric images using the simplified reference tissue model with the basis function method for [11C]raclopride
  • Cite Icon15
  • https://doi.org/10.1088/0031-9155/60/11/4533Copy DOI Icon

Direct 4D PET MLEM reconstruction of parametric images using the simplified reference tissue model with the basis function method for [11C]raclopride

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

This work assesses the one-step late maximum likelihood expectation maximization (OSL-MLEM) 4D PET reconstruction algorithm for direct estimation of parametric images from raw PET data when using the simplified reference tissue model with the basis function method (SRTM-BFM) for the kinetic analysis. To date, the OSL-MLEM method has been evaluated using kinetic models based on two-tissue compartments with an irreversible component. We extend the evaluation of this method for two-tissue compartments with a reversible component, using SRTM-BFM on simulated 3D + time data sets (with use of [11C]raclopride time-activity curves from real data) and on real data sets acquired with the high resolution research tomograph. The performance of the proposed method is evaluated by comparing voxel-level binding potential (BPND) estimates with those obtained from conventional post-reconstruction kinetic parameter estimation. For the commonly chosen number of iterations used in practice, our results show that for the 3D + time simulation, the direct method delivers results with lower %RMSE at the normal count level (decreases of 9–10 percentage points, corresponding to a 38–44% reduction), and also at low count levels (decreases of 17–21 percentage points, corresponding to a 26–36% reduction). As for the real 3D data set, the results obtained follow a similar trend, with the direct reconstruction method offering a 21% decrease in %CV compared to the post reconstruction method at low count levels. Thus, based on the results presented herein, using the SRTM-BFM kinetic model in conjunction with the OSL-MLEM direct 4D PET MLEM reconstruction method offers an improvement in performance when compared to conventional post reconstruction methods.

Similar Papers
  • Conference Article
  • Citations8

Direct reconstruction of PET receptor binding parametric images using a simplified reference tissue model

  • Feb 26, 2009
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Guobao Wang +1
  • Research Article
  • Citations19

A novel approach for direct reconstruction of parametric images for myocardial blood flow from PET imaging

  • Sep 12, 2013
  • Medical Physics
  • Kuan‐Hao Su +2
  • Research Article
  • Citations168

PET imaging of the effects of age and cocaine on the norepinephrine transporter in the human brain using (S,S)-[(11)C]O-methylreboxetine and HRRT.

  • Sep 02, 2009
  • Synapse
  • Yu-Shin Ding +11
  • Research Article
  • Citations11

Parametric [11C]flumazenil images

  • Apr 01, 2012
  • Nuclear Medicine Communications
  • Ursula M.H Klumpers +5
  • Research Article
  • Citations8

Discontinuous Galerkin via Interpolation: The Direct Flux Reconstruction Method

  • Mar 01, 2020
  • Journal of Scientific Computing
  • H T Huynh
  • Research Article
  • Citations39

Performance Evaluation of a High-Resolution Nonhuman Primate PET/CT System.

  • Jul 13, 2019
  • Journal of Nuclear Medicine
  • Zsolt Sarnyai +10
  • Research Article
  • Citations105

Characterization of age/sex and the regional distribution of mGluR5 availability in the healthy human brain measured by high-resolution [(11)C]ABP688 PET.

  • Aug 21, 2015
  • European Journal of Nuclear Medicine and Molecular Imaging
  • Jonathan M Dubois +9
  • Research Article
  • Citations21

Direct Estimation of Voxel-Wise Neurotransmitter Response Maps From Dynamic PET Data.

  • Nov 28, 2018
  • IEEE transactions on medical imaging
  • Georgios I. Angelis +4
  • Conference Article
  • Citations3

Robustness of Compressive Sensing under multiplicative perturbations: The challenge of fading channels

  • Oct 01, 2010
  • H Chae Daniel +2
  • Research Article

Deep Image Prior-Incorporated Direct PET Parametric Image Reconstruction.

  • Feb 09, 2026
  • IEEE transactions on medical imaging
  • Andi Li +3
  • Research Article
  • Citations2

Accurate 3D reconstruction by a new PDS-OSEM algorithm for HRRT

  • Sep 25, 2013
  • Radiation Physics and Chemistry
  • Tai-Been Chen +4
  • Research Article
  • Citations76

Dopamine D 2 receptor binding in drug-naïve patients with schizophrenia examined with raclopride-C11 and positron emission tomography

  • Nov 13, 2006
  • Psychiatry Research: Neuroimaging
  • Mirjam Talvik +6
  • Conference Article

Synthesised Direct Kinetic Parametric Image Reconstruction

  • Nov 01, 2025
  • Laurence Vass +1
  • Research Article
  • Citations6

3D PET image reconstruction including both motion correction and registration directly into an MR or stereotaxic spatial atlas

  • Dec 06, 2012
  • Physics in Medicine and Biology
  • Paul Gravel +2
  • Conference Article
  • Citations1

Comparison of methods for quantification of rCBF on the HRRT PET scanner using [<sup>15</sup>O]H<inf>2</inf>O

  • Oct 01, 2010
  • M D Walker +6
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.