• Home
  • Search
  • Direct torque control for interior permanent magnet synchronous motors with respect to optimal efficiency
  • Cite Icon31
  • https://doi.org/10.1109/epe.2007.4417370Copy DOI Icon

Direct torque control for interior permanent magnet synchronous motors with respect to optimal efficiency

  • Jan 1, 2007
  • Michael Meyer +2 more
Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Due to their high torque and power per volume ratio, interior permanent magnet synchronous motors (IPMSM) are widespread electrical machines for traction drive applications, e.g. in the drive train of hybrid electric vehicles (HEV). IPMSM exhibit a significant degree of saliency along the rotor circumference. Thus, in order to exploit the full potential of an IPMSM drive, it is mandatory to utilize the reluctance torque. As a result, using a rotor flux oriented torque control, the clear separation between flux and torque generating currents is no longer possible, i.e. that the determination of the reference currents for the subordinated current control is rather difficult. Furthermore, drive applications demand for a wide constant power range with flux weakening ratios of up to 1:5 or even higher. However, flux weakening operation demands for additional measures to ensure that the current controllers dispose of a minimum amount of voltage reserve, which is necessary to govern transients and to compensate for disturbances. In this contribution a Direct Torque Control (DTC) structure is proposed to cope with the afore mentioned problems. In a DTC structure, torque and flux are controlled directly. Hence, the approach is very well suited for operation at saturated voltage. Furthermore, with torque and flux as control variables, it is not necessary to determine any reference currents. However, the proposed structure utilizes two Look Up Tables (LUT) for the determination of efficiency-optimal set values for flux and torque. The LUT are generated based on measurement results. So, they do already account for saturation effects. The proposed DTC structure has been implemented and verified on a test bed.

Similar Papers
  • Research Article
  • Citations25

Sensorless direct torque control based on seven-level torque hysteresis controller for five-phase IPMSM using a sliding-mode observer

  • Mar 06, 2021
  • Engineering Science and Technology, an International Journal
  • Aykut Bıçak +1
  • Conference Article
  • Citations6

A novel deadbeat-direct torque and flux control of IPMSM with parameter identification

  • Sep 01, 2016
  • Lin Weijie +4
  • Conference Article
  • Citations12

Sensorless sliding mode control of an interior permanent magnet synchronous motor based on extended Kalman filter

  • Nov 17, 2003
  • Zhuang Xu +1
  • Conference Article
  • Citations7

Examination and Linearization of Torque Control System for Direct Torque Controlled IPMSM

  • Oct 01, 2008
  • Yukinori Inoue +2
  • Conference Article
  • Citations2

Direct Flux-Vector Oriented Control for Interior Permanent Magnet Synchronous Motor

  • Jul 27, 2022
  • Thien-Phuoc Nguyen +3
  • Conference Article
  • Citations4

Voltage vector selection area of interior permanent magnet synchronous motor direct torque control for electrical vehicle

  • Sep 01, 2011
  • Yaohua Li +4
  • Research Article
  • Citations74

Very low speed performance of active flux based sensorless control: interior permanent magnet synchronous motor vector control versus direct torque and flux control

  • Nov 01, 2009
  • IET Electric Power Applications
  • M.C Paicu +3
  • Conference Article
  • Citations5

Recent advances in direct torque and flux control of IPMSM drives

  • Dec 01, 2016
  • M Nasir Uddin +1
  • Conference Article
  • Citations5

The preliminary results on Direct Torque Control for an fractional-slot concentrated winding Interior Permanent Magnet Synchronous Machine

  • Jun 01, 2012
  • Dai Nguyen +2
  • Conference Article
  • Citations6

A modified direct torque control of IPM synchronous machine drive with constant switching frequency and low ripple in torque

  • May 01, 2010
  • A Daghigh +2
  • Conference Article
  • Citations4

Maximum torque/minimum flux control of Interior Permanent Magnet Synchronous Motor based on magnetic energy model

  • Jan 01, 2007
  • Masashi Takiguchi +3
  • Conference Article
  • Citations3

Improved Sensorless Direct Torque and Flux Control of IPMSM based on On-line Parameter Estimation

  • Oct 18, 2020
  • M X Bui +2
  • Conference Article
  • Citations7

Modification of electric drive vehicles performances using a direct torque control with over-modulation ability

  • Nov 01, 2015
  • Ahmad Ghaderi +3
  • Research Article
  • Citations8

Sensorless flux adaption DTFC of an IPMSM based on an active flux‐based MTPA and an adaptive second‐order sliding mode observer

  • May 13, 2020
  • IET Power Electronics
  • Junlei Chen +3
  • Conference Article
  • Citations1

Deadbeat Predictive Direct Torque and Active Flux Control with Disturbance Observer

  • Oct 13, 2021
  • S M Showybul Islam Shakib +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.