Dose calculation with a cone beam CT image in image-guided radiation therapy

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

A kilo-voltage cone-beam CT (CBCT) attached to a linear accelerator can verify a target position in each radiation therapy. If CBCT images can be used in dose calculation, we can verify an actual dose distribution on every treatment day. However, the CBCT images are degraded by several factors, and so we cannot use the CBCT images directly in place of conventional multi-slice CT (MSCT) images that are used in the initial dose planning. In this paper, we proposed a new method for using CBCT and MSCT images in the calculation of a dose distribution. Our proposed method segments the CBCT and MSCT images into regions of three major organs (lungs, bones and soft tissues) by use of histogram analysis. We also calculated a value such as the median of the MSCT numbers in each region of the MSCT images, and we set three representative values to the corresponding regions of the CBCT images. In the calculation of a dose distribution, we used these modified CBCT images. The validity of our method was confirmed with experiments in which we used images of a heterogeneous phantom and patients' lungs in comparison with conventional methods. The results showed that the dose distribution determined by our method was similar to that of the initial dose plan, and our method was superior to the conventional methods in terms of pass rates of a distance-to-agreement analysis and γ analysis. The results of a dose-volume-histogram analysis also showed the accuracy of our proposed method.

Similar Papers
  • Abstract

Improvement of Dose Calculation with Scattered Photon-Corrected kV Cone-Beam CT Image Using the Kernel Deconvolution Method

  • Sep 23, 2017
  • International Journal of Radiation Oncology*Biology*Physics
  • K Usui +3
  • Research Article

SU-E-J-100: Feasibility of Dose Calculation Using Combined Information of Cone-Beam and Multi-Slice CT Images.

  • Jun 01, 2012
  • Medical physics
  • K Usui +2
  • Book Chapter

Evaluation on Pixel Value Conversion Methods for Dose Calculation with Kilo-Voltage Cone Beam CT Images

  • Jan 01, 2013
  • K Usui +7
  • Research Article
  • Citations2

SU‐E‐I‐05: A Correction Algorithm for Kilovoltage Cone‐Beam Computed Tomography Dose Calculations in Cervical Cancer Patients

  • Jun 01, 2015
  • Medical Physics
  • J Zhang +2
  • Research Article
  • Citations22

Validity of three-dimensional computed tomography measurements for Le Fort I osteotomy

  • Jul 16, 2013
  • International Journal of Oral and Maxillofacial Surgery
  • B.F Gaia +4
  • Discussion

Authors' response.

  • Dec 01, 2018
  • American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics
  • Ahmad Abdelkarim +1
  • Abstract
  • Citations1

43. CBCT dose calculation: accuracy assessment of four different methods

  • Dec 01, 2017
  • Physica Medica
  • A Barateau +5
  • Research Article
  • Citations21

Image integration of three-dimensional cone-beam computed tomography angiogram into electroanatomical mapping system to guide catheter ablation of atrial fibrillation

  • Nov 27, 2009
  • Europace
  • K Ejima +9
  • Research Article
  • Citations17

Cone Beam Computed Tomography for Adaptive Radiotherapy Treatment Planning

  • Jan 01, 2014
  • Journal of Medical and Biological Engineering
  • Kavitha Srinivasan
  • Research Article
  • Citations38

Detection accuracy of proximal caries by phosphor plate and cone-beam computerized tomography images scanned with different resolutions

  • Jul 30, 2011
  • Clinical Oral Investigations
  • Jun-Ge Cheng +5
  • Research Article
  • Citations151

Three-dimensional C-arm Cone-beam CT: Applications in the Interventional Suite

  • Jul 01, 2009
  • Journal of Vascular and Interventional Radiology
  • Michael J Wallace +5
  • Research Article
  • Citations10

Use of gray values in CBCT and MSCT images for determination of density: influence of variation of FOV size.

  • Feb 19, 2015
  • Implant Dentistry
  • Andreia Fialho Rodrigues +4
  • Abstract

A New Scatter Correction Method for KV and MV Cone Beam CT

  • Aug 20, 2008
  • International Journal of Radiation Oncology*Biology*Physics
  • X Li +4
  • Research Article

SU‐FF‐I‐103: A Segmentation‐Based Deformable Registration Algorithm for Cone Beam CT and Helical CT Images

  • Jun 01, 2009
  • Medical Physics
  • X Li +4
  • Abstract
  • Citations1

How Long Does It Take? An Analysis Of Volumetric Image Assessment Time

  • Oct 01, 2011
  • International Journal of Radiation Oncology*Biology*Physics
  • W Li +2
Cactus Communications logo