• Home
  • Search
  • Dosimetric evaluation study of IMRT and VMAT techniques for prostate cancer based on different multileaf collimator designs
  • Cite Icon9
  • https://doi.org/10.1007/s00411-022-01011-2Copy DOI Icon

Dosimetric evaluation study of IMRT and VMAT techniques for prostate cancer based on different multileaf collimator designs

Show More
  • Abstract
  • PDF
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

The hypofractionated radiotherapy modality was established to reduce treatment durations and enhance therapeutic efficiency, as compared to conventional fractionation treatment. However, this modality is challenging because of rigid dosimetric constraints. This study aimed to assess the impact of multi-leaf collimator (MLC) widths (10 mm and 5 mm) on plan quality during the treatment of prostate cancer. Additionally, this study aimed to investigate the impact of the MLC mode of energy on the Agility flattening filter (FF), MLC Agility-free flattening filter (FFF), and MLCi2 for patients receiving hypofractionated radiotherapy. Two radiotherapy techniques; Intensity Modulated Radiotherapy (IMRT) and Volumetric Modulated Arc Radiotherapy (VMAT), were used in this research. In the present study, computed tomography simulations of ten patients (six plans per patient) with localized prostate adenocarcinoma were analyzed. Various dosimetric parameters were assessed, including monitor units, treatment delivery times, conformity, and homogeneity indices. To evaluate the plan quality, dose-volume histograms (DVHs) were estimated for each technique. The results demonstrated that the determined dosimetric parameters of planning target volume (PTV)p (such as D mean, conformity, and homogeneity index) showed greater improvement with MLC Agility FF and MLC Agility FFF than with MLCi2. Additionally, the treatment delivery time was reduced in the MLC Agility FF (by 31%) and MLC Agility FFF (by 10.8%) groups compared to the MLCi2 group. It is concluded that for both the VMAT and IMRT techniques, the smaller width (5 mm) MLCs revealed better planning target volume coverage, improved the dosimetric parameters for PTV, reduced the treatment time, and met the constraints for OARs. It is therefore recommended to use 5 mm MLCs for hypofractionated prostate cancer treatment due to better target coverage and better protection of OARs.

Loading PDF

Similar Papers
  • Research Article

SU-E-T-302: Dosimetric Comparison Between Volumetric Modulated Arc Radiotherapy and Intensity-Modulated Radiotherapy for Locally Recurrent Nasopharyngeal Carcinoma

  • Jun 01, 2015
  • Medical Physics
  • J-Y Lu +3
  • Research Article

Abstract P4-12-32: Intensity modulated radiotherapy (IMRT) for breast and lymph node irradiation

  • Feb 14, 2020
  • Cancer Research
  • Wassim El Amine +10
  • Research Article

Advantages and disadvantages of removed flattening filter Linac: A Monte Carlo study on full quantitative dosimetric data of 18 MV-Varian Linac

  • Dec 01, 2018
  • Iranian Journal of Medical Physics
  • Mansour Zabihzadeh +3
  • Research Article

Comparison of Dose Distribution to Target Volume and Organs at Risk using 3D CRT, IMRT, and VMAT Techniques in Glioblastoma Cases

  • Jun 01, 2023
  • International Journal of Scientific Research in Science and Technology
  • Hamzah Fuadi +5
  • Research Article
  • Citations54

Volumetric Modulated Arc Therapy vs. IMRT for the Treatment of Distal Esophageal Cancer

  • Mar 05, 2011
  • Medical Dosimetry
  • Liam Van Benthuysen +2
  • Research Article
  • Citations15

Comparing dose in the build‐up region between compensator‐ and MLC‐based IMRT

  • Sep 01, 2012
  • Journal of Applied Clinical Medical Physics
  • Khosrow Javedan +4
  • Research Article
  • Citations2

The effect of multi‐leaf collimator leaf width on VMAT treatment plan quality

  • Mar 13, 2025
  • Journal of Applied Clinical Medical Physics
  • Gregory Sadharanu Peiris +3
  • Research Article
  • Citations24

Inverse and forward optimization of one- and two-dimensional intensity-modulated radiation therapy-based treatment of concave-shaped planning target volumes: the case of prostate cancer.

  • Dec 14, 2002
  • Radiotherapy and Oncology
  • Daniela Corletto +8
  • PDF
  • Research Article

Comparative Study of Fast Superposition, Superposition Algorithm in Intensity Modulated Radiotherapy Techniques for Prostate Cancer

  • Jan 01, 2020
  • International Journal of Medical Physics, Clinical Engineering and Radiation Oncology
  • Mukesh Zope +5
  • PDF
  • Research Article
  • Citations23

Dosimetric and Radiobiological Comparison of External Beam Radiotherapy Using Simultaneous Integrated Boost Technique for Esophageal Cancer in Different Location

  • Jul 25, 2019
  • Frontiers in Oncology
  • Lu Wang +9
  • Research Article
  • Citations13

Protection of organs at risk during neoadjuvant chemoradiotherapy for gastric cancer based on a comparison between conformal and intensity-modulated radiation therapy.

  • May 26, 2016
  • Oncology Letters
  • Leszek Hawrylewicz +4
  • PDF
  • Research Article
  • Citations1

Dosimetric analysis of intensity modulated radiotherapy (IMRT) and three dimensional conformal radiotherapy (3DCRT) for treatment of non-small cell lung cancer: A comparative study

  • Sep 25, 2015
  • International Journal of Cancer Therapy and Oncology
  • Priyusha Bagdare +2
  • Research Article
  • Citations3

A multileaf collimator phantom for the quality assurance of radiation therapy planning systems and CT simulators

  • Nov 01, 2004
  • International Journal of Radiation OncologyBiologyPhysics
  • A Mcniven +2
  • Research Article

DOSIMETRIC COMPARISON OF INTENSITY-MODULATED RADIATION THERAPY (IMRT) AND VOLUMETRIC-MODULATED ARC THERAPY (VMAT) IN RECTAL CANCER PATIENTS: A COMPREHENSIVE ANALYSIS

  • Mar 14, 2024
  • Biological and Clinical Sciences Research Journal
  • S Shafique +3
  • PDF
  • Research Article
  • Citations18

Comparison of Dosimetric Gains Provided by Intensity-Modulated Radiotherapy, Volume-Modulated Arc Therapy, and Helical Tomotherapy for High-Grade Glioma

  • Jan 01, 2020
  • BioMed Research International
  • Pei Liu +10
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.