• Home
  • Search
  • Dynamic collimation for missing tissue compensation
  • https://doi.org/10.1109/iembs.2000.900705Copy DOI Icon

Dynamic collimation for missing tissue compensation

  • Jul 23, 2000
  • S Papatheodorou +4 more
Show More
  • Abstract
  • Literature Map
  • References
  • Similar Papers
Abstract

In external radiotherapy, the use of missing tissue compensation has been proposed for the improvement of dose distributions resulting from radiation beams entering through oblique or irregular surfaces of the patient. The well-known inconveniences related to conventional compensators justify the investigation of alternative techniques such as the use of dynamic multileaf collimators. The combination of a number of software and hardware modules was necessary for the implementation of dynamic collimation for missing tissue compensation. First, a software module that calculates, with a ray-tracing technique, the missing-tissue deficit from computed tomography scans and generates a desired 2D intensity modulation pattern has been developed. Then a second software module that converts the 2D intensity map to a leaf motion plan for practical delivery with dynamic collimators has been implemented. Finally, the existing primary-scatter separation dose model of the authors' TPS had to be extended to account for the intensity modulation generated by the dynamic MLC. As an example of the 'virtual' compensator technique, the MLC sequence that would compensate an arbitrary patient irregular surface has been calculated. Then, film was used to measure the dose on a plane perpendicular to the beam axis at the specified depth of compensation. A comparison between measured and calculated dose distributions shows that an acceptable accuracy in dose calculations can be achieved. Finally a comparison between uncompensated and dynamically compensated fields demonstrates that the 'virtual' compensator was able to flatten the off-axis dose across a plane perpendicular to the beam axis at the depth of compensation.

Similar Papers
  • Research Article
  • Citations39

Comparing the accuracy of four‐dimensional photon dose calculations with three‐dimensional calculations using moving and deforming phantoms

  • Oct 02, 2009
  • Medical Physics
  • Yevgeniy Y Vinogradskiy +5
  • Research Article
  • Citations117

A method for photon beam Monte Carlo multileaf collimator particle transport

  • Aug 21, 2002
  • Physics in Medicine & Biology
  • Jeffrey V Siebers +3
  • Research Article
  • Citations2

Evaluation of dose calculation accuracy of a commercial radiotherapy treatment planning system for adjacent radiation fields

  • Jan 01, 2023
  • Journal of Radiotherapy in Practice
  • Ali Rasouli +3
  • Book Chapter
  • Citations2

JCIT, A Production-Ready Field Tested Non- Proprietary Software Definable Radio

  • Jan 01, 2001
  • Robert F. Higgins +1
  • Research Article
  • Citations20

Virtual Prototyping For Modular And Flexible Hardware-Software Systems

  • Jan 01, 1997
  • Design Automation for Embedded Systems
  • Carlos A Valderrama +2
  • Research Article
  • Citations37

On the dose to a moving target while employing different IMRT delivery mechanisms

  • Mar 09, 2007
  • Radiotherapy and Oncology
  • Eric D Ehler +2
  • Research Article
  • Citations2

Technical note: A fast and accurate analytical dose calculation algorithm for 125 I seed-loaded stent applications.

  • Sep 16, 2021
  • Medical Physics
  • Bo Liu +6
  • Abstract

Evaluation of a Model-based Dose Calculation Algorithm (Acuros) for Intraosseous High Dose Rate Brachytherapy (HDR) With Intramedullary Nailing for Bone Metastases

  • Oct 23, 2020
  • International Journal of Radiation Oncology*Biology*Physics
  • N Hassan Rezaeian +4
  • Research Article
  • Citations36

Improved dose calculation accuracy for low energy brachytherapy by optimizing dual energy CT imaging protocols for noise reduction using sinogram affirmed iterative reconstruction

  • Oct 01, 2015
  • Zeitschrift für Medizinische Physik
  • Guillaume Landry +4
  • Research Article
  • Citations40

Accuracy of dose calculation based on artefact corrected Cone Beam CT images of lung cancer patients

  • Jan 01, 2017
  • Physics and Imaging in Radiation Oncology
  • Rune Slot Thing +3
  • Research Article
  • Citations1

A novel dose calculation system implemented in image domain.

  • May 21, 2025
  • Medical physics
  • Jiawei Fan +6
  • Abstract

Abstract ID: 160 Advanced personalised 3D dosimetry based on Monte Carlo simulation for Peptide Receptor Radionuclide Therapy

  • Oct 01, 2017
  • Physica Medica
  • Salvatore Berenato +5
  • Conference Article
  • Citations2

Research and development of the laser tracker measurement system

  • Jan 31, 2013
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Z L Zhang +5
  • Conference Article
  • Citations2

In-house Testing of Highly Hardware-dependent Software

  • Apr 03, 2006
  • SAE technical papers on CD-ROM/SAE technical paper series
  • Rafael Zalman +3
  • Research Article
  • Citations2

On three-dimensional dose calculation of photon beam with wedge filters.

  • Jun 01, 1994
  • Medical physics
  • Jonathan Y Yao +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.