• Home
  • Search
  • Dynamic fluence field modulation in computed tomography using multiple aperture devices
  • Open Access IconOpen Access
  • Cite Icon16
  • https://doi.org/10.1088/1361-6560/ab155eCopy DOI Icon

Dynamic fluence field modulation in computed tomography using multiple aperture devices

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

A novel beam filter consisting of multiple aperture devices (MADs) has been developed for dynamic fluence field modulation (FFM) in CT. Each MAD achieves spatial modulation of x-ray through fine-scale, highly attenuating tungsten bars of varying widths and spacings. Moiré patterns produced by relative motions between two MADs provide versatile classes of modulation profiles. The dual-MAD filter can be designed to achieve specific classes of target profiles. The designed filter was manufactured through a laser-sintering process and integrated to an experimental imaging system that enables linear actuation of the MADs. Dynamic FFM was achieved through a combination of beam shape modulation (by relative MAD motion) and amplitude modulation (by view-dependent mAs). To correct for gains associated with the MADs, we developed an algorithm to account for possible focal spot changes during/between scans and spectral effects introduced by the MADs. We performed FFM designs for phantoms following two imaging objectives: (1) to achieve minimum mean variance in filtered backprojection (FBP) reconstruction, and (2) to flatten the fluence behind the phantom. Comparisons with conventional FFM strategies involving a static bowtie and pulse width modulation were performed. The dual-MAD filter produced modulation profiles closely matched with the design target, providing varying beam widths not achievable by the static bowtie. The entire range of modulation profiles was achieved by 0.373 mm of MAD displacement. The correction algorithm effectively alleviated ring artifacts as a result of MADs while preserving phantom details such as wires and tissue boundaries. Dynamic FFM enabled by the MADs were effective in achieving the imaging objectives and demonstrated superior FFM capabilities compared to the static bowtie. In an ellipse phantom, the FFM of objective 1 achieved the lowest mean variance in all cases investigated. The FFM of objective 2 produce nearly isotropic local noise power spectrum and homogeneous noise magnitude. The dual-MAD filter provides an effective tool for fluence control in CT to overcome limitations of conventional static bowties and to further enable patient-specific FFM studies for a wide range of dose and image quality objectives.

Similar Papers
  • Research Article
  • Citations41

Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction

  • Oct 15, 2013
  • European Radiology
  • Joris M Niesten +8
  • Research Article
  • Citations44

Third-generation dual-source 70-kVp chest CT angiography with advanced iterative reconstruction in young children: image quality and radiation dose reduction.

  • Jan 06, 2016
  • Pediatric Radiology
  • Oliver Rompel +7
  • Research Article
  • Citations53

Model-Based Iterative Reconstruction (MBIR) for the Reduction of Metal Artifacts on CT.

  • Aug 01, 2015
  • American Journal of Roentgenology
  • Sana Boudabbous +5
  • PDF
  • Research Article
  • Citations5

Diagnostic performance and image quality of iterative model-based reconstruction of coronary CT angiography using 100 kVp for heavily calcified coronary vessels

  • Sep 10, 2019
  • PLoS ONE
  • Junwoo Kim +7
  • Research Article
  • Citations14

Improving head and neck CTA with hybrid and model-based iterative reconstruction techniques

  • Jul 27, 2015
  • Clinical Radiology
  • J.M Niesten +4
  • Research Article
  • Citations49

Ultra-low dose abdominal MDCT: Using a knowledge-based Iterative Model Reconstruction technique for substantial dose reduction in a prospective clinical study

  • Oct 13, 2014
  • European Journal of Radiology
  • Ranish Deedar Ali Khawaja +13
  • PDF
  • Research Article
  • Citations5

Effect of Low Tube Voltage (100 kV) Combined with ASIR-V on the Visualization and Image Quality of the Adamkiewicz Artery: A Comparison with 120 kV Protocol.

  • Jul 27, 2023
  • Diagnostics
  • Jiantao Deng +10
  • Research Article
  • Citations3

Effect of iDose4 iterative reconstruction algorithm on image quality and radiation exposure in prospective and retrospective electrocardiographically gated coronary computed tomographic angiography.

  • Jan 01, 2014
  • Journal of computer assisted tomography
  • Sofia D Kordolaimi +7
  • Research Article
  • Citations7

Image Quality Assessment in Torso Phantom Comparing Effects of Varying Automatic Current Modulation with Filtered Back Projection, Adaptive Statistical, and Model-Based Iterative Reconstruction Techniques in CT

  • Oct 23, 2012
  • Journal of Medical Imaging and Radiation Sciences
  • Varut Vardhanabhuti +5
  • Research Article
  • Citations13

The value of a deep learning image reconstruction algorithm in whole-brain computed tomography perfusion in patients with acute ischemic stroke.

  • Dec 01, 2023
  • Quantitative Imaging in Medicine and Surgery
  • Limin Lei +7
  • Research Article
  • Citations9

Model-based Iterative Reconstruction in Low-radiation-dose Computed Tomography Colonography: Preoperative Assessment in Patients with Colorectal Cancer

  • Nov 27, 2017
  • Academic Radiology
  • Narumi Taguchi +13
  • Research Article

On-off spacecraft relative control in sliding mode via reinforcement learning

  • Dec 11, 2025
  • Technical mechanics
  • V.V Sorochinskii +5
  • Research Article
  • Citations19

Combined Use of Automatic Tube Voltage Selection and Current Modulation with Iterative Reconstruction for CT Evaluation of Small Hypervascular Hepatocellular Carcinomas: Effect on Lesion Conspicuity and Image Quality

  • Jan 01, 2015
  • Korean Journal of Radiology
  • Peijie Lv +4
  • Research Article
  • Citations26

Emulating Scaled Clohessy–Wiltshire Dynamics on an Air-Bearing Spacecraft Simulation Testbed

  • Jun 05, 2017
  • Journal of Guidance, Control, and Dynamics
  • Marco Ciarcià +2
  • Research Article
  • Citations3

SPACECRAFT RELATIVE ON-OFF CONTROL VIA REINFORCEMEN T LEARNING

  • Apr 29, 2024
  • Kosmìčna nauka ì tehnologìâ
  • S V Khoroshylov +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.