• Home
  • Search
  • Dynamic Response Improvement of a Three-Phase Line Interactive UPS System with Active Power Line Conditioning
  • Cite Icon6
  • https://doi.org/10.1109/pesc.2007.4342138Copy DOI Icon

Dynamic Response Improvement of a Three-Phase Line Interactive UPS System with Active Power Line Conditioning

  • Jan 1, 2007
  • Sergio Augusto Oliveira Da Silva +2 more
Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

This paper presents an improved method to generate the compensation reference currents applied to a three-phase line-interactive Uninterruptible Power Supply (UPS) system with series and parallel active power line conditioning capabilities. The reference currents are used to compensate the reactive power and to eliminate harmonic currents generated from the non-linear loads, in a three-phase, four-wire system. The control strategy is based on the synchronous reference frame (SRF) method and the implemented current SRF-based controller does not have the task of compensating negative and zero sequence components at fundamental frequency of the load currents, due to unbalanced loads or unbalance source voltage conditions. Thus, the efficiency of the three-phase UPS system is increased when it is feeding unbalanced single-phase non-linear loads because the PWM parallel converter compensates only the harmonic load currents. Three strategies, employed to generate the reference currents, are discussed, such as, the SRF conventional strategy, the SRF single-phase strategy and the improved SRF single-phase strategy. Besides, the active powers that flow through the parallel PWM converter using the three presented strategies are shown and a comparative analysis of them is made to validate the predicted theoretical results.

Similar Papers
  • Conference Article
  • Citations54

Advanced Synchronous Reference Frame Controller for Three-phase UPS Powering Unbalanced and Nonlinear Loads

  • Jun 16, 2005
  • Kyung-Hwan Kim +2
  • Conference Article
  • Citations8

A high performance controller for parallel operation of three-phase UPSs powering unbalanced and nonlinear loads

  • Feb 01, 2011
  • S.M Dehghan +5
  • Conference Article
  • Citations5

Robust control design of multiple resonant controllers applied to three-phase UPS inverter under unbalanced and nonlinear loads

  • Nov 01, 2015
  • Alisson Thomas Barden +1
  • Research Article
  • Citations136

A new space-vector-based control method for UPS systems powering nonlinear and unbalanced loads

  • Jan 01, 2001
  • IEEE Transactions on Industry Applications
  • U Burup +2
  • Conference Article
  • Citations5

LCL filter design for a modular power conditioning system with uninterruptible power supply capability

  • Oct 01, 2017
  • Florian Bendrat +2
  • Conference Article

Novel reduced switches single-phase to three-phase on-line uninterruptible power supply

  • Sep 01, 2011
  • Mehrnaz Sharifian +1
  • Conference Article
  • Citations42

Model predictive control of a VSI with long prediction horizon

  • Jun 01, 2011
  • Sergio Vazquez +3
  • Conference Article
  • Citations1

Design of controller for inverters with ultra-low THD: A repetitive and predictive-PID controller approach

  • Sep 01, 2017
  • Bunyamin Tamyurek +1
  • Research Article
  • Citations156

An Adaptive Control for UPS to Compensate Unbalance and Harmonic Distortion Using a Combined Capacitor/Load Current Sensing

  • Apr 01, 2007
  • IEEE Transactions on Industrial Electronics
  • G Escobar +4
  • Conference Article
  • Citations1

A new approach to design digital controller for three phase active power line conditioner for harmonic compensation using 8051 microcontroller

  • Aug 01, 2016
  • Saswat Kumar Ram +1
  • Conference Article
  • Citations11

Comparison of different control strategy of conventional and digital controller for active power line conditioner (APLC) for harmonic compensation

  • May 01, 2013
  • S K Ram +1
  • Conference Article
  • Citations8

Performance analysis of PV grid-connected power conditioning system with UPS

  • May 01, 2009
  • Xiaogao Chen +2
  • Conference Article
  • Citations4

Reactive power control strategy based on DC capacitor voltage control for active load balancer in three-phase four-wire distribution systems

  • May 01, 2014
  • Tint Soe Win +5
  • Conference Article
  • Citations1

Measuring of Inactive Powers in Three-Phase Power Supply System

  • Oct 20, 2022
  • M Yu Artemenko +5
  • Research Article
  • Citations4

Fryze Current Controller Based Active Power Filter

  • Jan 01, 2014
  • IFAC Proceedings Volumes
  • Manish Kr Singh +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.