Abstract

Electrocardiogram (ECG) acquisition is easily contaminated by interferences, and denoising is the most important task in ECG detection. The variational mode decomposition (VMD) algorithm is widely used in ECG denoising, which can overcome mode aliasing between intrinsic mode function (IMF) components that existed in the traditional empirical mode decomposition (EMD) algorithm, but the mode decomposition number <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${K}$ </tex-math></inline-formula> and penalty factor <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\alpha $ </tex-math></inline-formula> in VMD must be optimized to obtain the best signal decomposition accuracy. This article proposes an improved VMD denoising algorithm that overcomes the shortcomings of slow parameter selection and poor generalization in the traditional VMD algorithm. The algorithm presented first adopts the EMD algorithm to remove the low-frequency baseline drift noise and then employs the adaptive particle swarm optimization (APSO) algorithm to optimize the parameter pair ( <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${K}$ </tex-math></inline-formula> , <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\alpha $ </tex-math></inline-formula> ) for VMD. To validate the denoising performance of the improved VMD algorithm, the No. 103 record from the Massachusetts Institute of Technology (MIT) arrhythmia database is first selected as the pure ECG signal, then both 20-dB Gaussian white noises and 0.3-Hz baseline drift are added to simulate the noisy ECG signal. Second, the ECG signals of nine subjects are collected by a customized ECG detection platform based on AD8232 and ADALM1000. The ECG denoising results in simulation and actual experiments show that the improved VMD algorithm achieves the highest signal-to-noise ratio (SNR), correlation coefficient (CC), and minimum mean square error (MSE) compared with the traditional EMD and VMD algorithms, which demonstrates that the proposed denoising algorithm has stronger denoising ability and better retains morphological characteristics of the original ECG signals.

Similar Papers
  • PDF
  • Research Article
  • Citations123

Gear Fault Diagnosis Based on Genetic Mutation Particle Swarm Optimization VMD and Probabilistic Neural Network Algorithm

  • Jan 01, 2020
  • IEEE Access
  • Jiakai Ding +2
  • PDF
  • Research Article
  • Citations3

Research on motor rotation anomaly detection based on improved VMD algorithm

  • Jan 19, 2024
  • Railway Sciences
  • Fuzhao Chen +6
  • PDF
  • Research Article
  • Citations10

Application of VMD and Hilbert Transform Algorithms on Detection of the Ripple Components of the DC Signal

  • Feb 19, 2020
  • Energies
  • Derong Luo +4
  • PDF
  • Research Article
  • Citations17

A Hybrid Short-Term Traffic Flow Multistep Prediction Method Based on Variational Mode Decomposition and Long Short-Term Memory Model

  • Oct 12, 2021
  • Discrete Dynamics in Nature and Society
  • Qichun Bing +5
  • PDF
  • Research Article
  • Citations33

Fusion of GNSS and Speedometer Based on VMD and Its Application in Bridge Deformation Monitoring.

  • Jan 27, 2020
  • Sensors
  • Ruicheng Zhang +3
  • PDF
  • Research Article
  • Citations4

Location Detection Method of Detector in Pipeline Using VMD Algorithm and Machine Learning Classifier

  • Jun 15, 2021
  • Electronics
  • Tuoru Li +2
  • PDF
  • Research Article
  • Citations93

Denoising and Feature Extraction Algorithms Using NPE Combined with VMD and Their Applications in Ship-Radiated Noise

  • Nov 01, 2017
  • Symmetry
  • Yuxing Li +3
  • Research Article
  • Citations11

Root Crack Identification of Sun Gear in Planetary Gear System Combining Fault Dynamics with VMD Algorithm

  • Jan 01, 2021
  • Shock and Vibration
  • Hongwei Fan +8
  • Research Article
  • Citations1

Electrocardiogram signal reconstruction based on mode component identification by heartbeat physical feature in improved empirical mode decomposition domain

  • Jan 01, 2021
  • Acta Physica Sinica
  • Xiao-Dong Niu +5
  • Conference Article
  • Citations3

Application of VMD Algorithm in UGW-based Rail Breakage Detection System

  • Sep 01, 2018
  • Lei Yuan +3
  • PDF
  • Research Article
  • Citations12

An Online Hybrid Model for Temperature Prediction of Wind Turbine Gearbox Components

  • Oct 16, 2019
  • Energies
  • Qiang Zhao +4
  • Research Article
  • Citations5

Non-stationary signal analysis utilizing VMD and EMD algorithm for multiple fault classification for industrial applications

  • Apr 08, 2024
  • Journal of Intelligent &amp; Fuzzy Systems: Applications in Engineering and Technology
  • R Pavithra +1
  • Research Article
  • Citations12

Damage Detection of Composite Beams via Variational Mode Decomposition of Shear-Slip Data

  • Jan 01, 2023
  • Journal of Structural Engineering
  • Faraz Sadeghi +5
  • Research Article
  • Citations35

Application of variational mode decomposition to seismic random noise reduction

  • Jun 13, 2017
  • Journal of Geophysics and Engineering
  • Wei Liu +2
  • Conference Article

Blind Separation of Transformer Vibration Signal Based on Sensitive IMFs

  • Oct 15, 2021
  • Zhen Li +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.