• Home
  • Search
  • Effect of computer-aided design and computer-aided manufacturing technique on the accuracy of fixed partial denture patterns used for casting or pressing
  • Cite Icon7
  • https://doi.org/10.1016/j.jdent.2023.104434Copy DOI Icon

Effect of computer-aided design and computer-aided manufacturing technique on the accuracy of fixed partial denture patterns used for casting or pressing

Show More
  • Abstract
  • PDF
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

ObjectivesTo evaluate the effect of additive and subtractive manufacturing on the accuracy (trueness and precision) of fixed partial denture patterns (FPDPs) used for casting or pressing. Materials and MethodsA 3-unit complete coverage FPD on mandibular right first premolar and first molar teeth was virtually designed. Using the design data, FPD patterns were fabricated from an additively manufactured resin (PR, ProArt Print Wax) and 2 CAD-CAM wax discs (YW, ProArt CAD Wax Yellow and BW, ProArt CAD Wax Blue) (n = 10). Each pattern was then digitized with a scanner (CEREC Primescan) and evaluated for 3D surface deviation at 4 different surfaces (overall, external, marginal, and intaglio surfaces) by using a 3D analysis software (Medit Link). Root mean square (RMS) values were automatically calculated. Data were analyzed by using Kruskal-Wallis and Dunn's post hoc tests for trueness and precision (α= 0.05). ResultsSignificant differences were found among the RMS values for overall (P<.001) and each surface (P≤.040) evaluated. PR had the highest overall (P≤.011) and intaglio surface (P≤.01) deviations, while the difference between YW and BW was not significant (P≥.199). PR had the highest (P≤.027) and BW had the lowest (P≤.042) external surface mean RMS values. BW had higher mean marginal RMS value than YW (P=.047). For precision, significant differences were observed among test groups only for marginal RMS values (P=.002). PR had lower precision than BW (P=.002). ConclusionsBW and YW FPDPs mostly had higher trueness compared with PR FPDPs. However, considering relatively smaller deviations at marginal and intaglio surfaces and the fact that patterns mostly had similar precision, clinical fit of FPDs fabricated by using tested patterns may be similar. Clinical SignificanceDefinitive 3-unit fixed partial dentures fabricated by using tested patterns may be similar. However, FPDs fabricated with tested additively manufactured resin patterns might result in more chairside adjustments than those fabricated with tested subtractively manufactured wax patterns.

Loading PDF

Similar Papers
  • Research Article
  • Citations21

Comparison of trueness and margin quality of additively and subtractively manufactured definitive resin-based laminate veneers

  • Oct 28, 2023
  • The Journal of prosthetic dentistry
  • Deniz Yılmaz +5
  • Research Article
  • Citations1

Influence of Gingival Color and Finish Line Location on the Accuracy of Intraoral Scans for Complete-Arch Tooth Preparation.

  • Jul 01, 2025
  • The International journal of prosthodontics
  • Nazmiye Şen +1
  • PDF
  • Research Article
  • Citations41

A Comparative Study of Additive and Subtractive Manufacturing Techniques for a Zirconia Dental Product: An Analysis of the Manufacturing Accuracy and the Bond Strength of Porcelain to Zirconia.

  • Aug 05, 2022
  • Materials
  • Joon-Mo Moon +7
  • Research Article
  • Citations1

The effect of irrigation solutions and sterilization process on the surface properties of ProTaper Next and TruNatomy rotary files: An atomic force microscopy study

  • Aug 31, 2022
  • International Dental Research
  • Faruk Öztekin +1
  • Research Article

Improvement of an existing method of asynchronous sampling for determining RMS value

  • Jan 01, 2018
  • Serbian Journal of Electrical Engineering
  • Stefan Mirkovic +4
  • Research Article
  • Citations133

Inhomogeneities in muscle activation reveal motor unit recruitment

  • Dec 08, 2004
  • Journal of Electromyography and Kinesiology
  • Andreas Holtermann +2
  • PDF
  • Research Article
  • Citations23

Comparison of three different types of exercises for selective contractions of supra- and infrahyoid muscles

  • Mar 30, 2021
  • Scientific Reports
  • Min Cheol Chang +6
  • PDF
  • Research Article
  • Citations6

Investigating the Performance of IGS Real-Time Global Ionospheric Maps under Different Solar Conditions

  • Sep 22, 2023
  • Remote Sensing
  • Hang Liu +2
  • Conference Article
  • Citations54

Development of BGA solder joint vibration fatigue life prediction model

  • Jun 01, 1999
  • T.E Wong +3
  • Research Article
  • Citations3

Analog and digital complete denture bases accuracy and dimensional stability: An in-vitro evaluation at 24 hours and 6 months.

  • Jun 01, 2025
  • Journal of dentistry
  • Alessio Casucci +4
  • Research Article
  • Citations16

The effect of glide path on the surface quality of new and used rotary and reciprocating single files: OneShape versus WaveOne.

  • Sep 03, 2014
  • Scanning
  • Sevinç Aktemur Türker +3
  • Research Article
  • Citations10

Atomic force microscopy and energy dispersive X-ray spectrophotometry analysis of reciprocating and continuous rotary nickel-titanium instruments following root canal retreatment.

  • Mar 27, 2019
  • Microscopy Research and Technique
  • Bulem Üreyen Kaya +2
  • Research Article
  • Citations20

A statistical analysis of acoustic emission signals for tool condition monitoring (TCM)

  • Jan 01, 2003
  • Acoustics Research Letters Online
  • G Pontuale +3
  • Research Article

Control of the RMS Output Current in Series Resonant Converters

  • Jan 01, 2024
  • IFAC PapersOnLine
  • Manon Doré +1
  • Research Article
  • Citations33

Neural mechanism of activity spread in the cat motor cortex and its relation to the intrinsic connectivity

  • May 13, 2011
  • The Journal of Physiology
  • Charles Capaday +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.