• Home
  • Search
  • Effect of Spectral Resolution on Pattern Recognition Analysis Using Passive Fourier Transform Infrared Sensor Data
  • Cite Icon8
  • https://doi.org/10.1366/0003702991945722Copy DOI Icon

Effect of Spectral Resolution on Pattern Recognition Analysis Using Passive Fourier Transform Infrared Sensor Data

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

The Fourier transform infrared (FT-IR) spectral data of two nerve agent simulants, diisopropyl methyl phosphonate (DIMP) and dimethyl methyl phosphonate (DMMP), are used as test cases to determine the spectral resolution that gives optimal pattern recognition performance. DIMP is used as the target analyte for detection, while DMMP is used to test the ability of the automated pattern recognition methodology to detect the analyte selectively. Interferogram data are collected by using a Midac passive FT-IR instrument. The methodology is based on the application of pattern recognition techniques to short segments of single-beam spectra obtained by Fourier processing the collected interferogram data. The work described in this article evaluates the effect of varying spectral resolution on the pattern recognition results. The objective is to determine the optimal spectral resolution to be used for data collection. The results of this study indicate that the data with a nominal spectral resolution of 16 cm −1 provide sufficient selectivity to give pattern recognition results comparable to that obtained by using higher resolution data. We found that, while higher resolution does not increase selectivity sufficiently to provide better pattern recognition results, lower resolution decreases selectivity and degrades the pattern recognition results. These results can be used as guidelines to maximize detection sensitivity, to minimize the time needed for data collection, and to reduce data storage requirements.

Similar Papers
  • Research Article
  • Citations2

Photoionization induced chemical ionization time-of-flight mass spectrometry for rapid and sensitive detection of trace gaseous chemical warfare agents.

  • Oct 01, 2025
  • Journal of chromatography. A
  • Yingzhe Guo +7
  • PDF
  • Research Article
  • Citations21

MAPLE Assembled Acetylcholinesterase⁻Polyethylenimine Hybrid and Multilayered Interfaces for Toxic Gases Detection.

  • Dec 04, 2018
  • Sensors
  • Valentina Dinca +10
  • PDF
  • Preprint Article

High-Temperature Decomposition of Diisopropyl Methylphosphonate (DIMP) on Alumina: Mechanistic Predictions from Ab Initio Molecular Dynamics

  • Sep 20, 2021
  • ChemRxiv
  • Sohag Biswas +1
  • Conference Article
  • Citations2

Novel gas sensor based on nano-zeolite films for the nerve agent simulant dimethylmethylphosphonate detection

  • Oct 18, 2004
  • Haifen Xie +4
  • Research Article
  • Citations15

Removal of diisopropyl methyl phosphonate (DIMP) from heated metal oxide surfaces.

  • Feb 01, 2023
  • Journal of Hazardous Materials
  • Ashvin Vasudevan +3
  • Research Article
  • Citations15

Detection of gaseous organophosphorus compounds using secondary ion mass spectrometry

  • Apr 01, 1985
  • Analytical Chemistry
  • Gary S Groenewold +1
  • Research Article
  • Citations77

Capacitive micromachined ultrasonic transducer (CMUT) as a chemical sensor for DMMP detection

  • Sep 17, 2011
  • Sensors and Actuators B: Chemical
  • Kwan Kyu Park +8
  • Research Article
  • Citations19

Investigation of the Persistence of Nerve Agent Degradation Analytes on Surfaces through Wipe Sampling and Detection with Ultrahigh Performance Liquid Chromatography-Tandem Mass Spectrometry

  • Dec 23, 2014
  • Analytical Chemistry
  • Stuart A Willison
  • Research Article
  • Citations31

Closer Look at Adsorption of Sarin and Simulants on Metal–Organic Frameworks

  • Mar 28, 2023
  • ACS Applied Materials & Interfaces
  • Alina Emelianova +4
  • Research Article
  • Citations103

Vapor Pressure of Organophosphorus Nerve Agent Simulant Compounds

  • Apr 22, 2009
  • Journal of Chemical & Engineering Data
  • Ann B Butrow +2
  • Research Article
  • Citations39

Sodium X-type faujasite zeolite decomposition of dimethyl methylphosphonate (DMMP) to methylphosphonate: Nucleophilic zeolite reactions I

  • Feb 09, 2006
  • Microporous and Mesoporous Materials
  • Szu-Wei Yang +8
  • Research Article
  • Citations29

Adsorptive removal of nerve-agent simulant with zirconium-based metal-organic frameworks modified by hydrophobic monocarboxylic acids

  • Apr 20, 2019
  • Microporous and Mesoporous Materials
  • Kyung Ho Cho +7
  • Research Article
  • Citations12

Bio‐based rigid polyurethane foam composites reinforced with flame retardants: From synthesis to performance evaluation

  • Jan 04, 2024
  • Journal of Applied Polymer Science
  • Emre Akdogan +3
  • News Article

Mineral fillers for glass mat thermoplastics

  • Jan 01, 1989
  • Additives for Polymers
  • Book Chapter
  • Citations4

Application of Pattern Recognition Techniques in the Development of Electronic Tongues

  • Aug 19, 2014
  • Maiara O. Salles +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.