ELPHA: Dynamically deformable liver phantom for real-time motion-adaptive radiotherapy treatments.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Real-time motion-adaptive radiotherapy of intrahepatic tumors needs to account for motion and deformations of the liver and the target location within. Phantoms representative of anatomical deformations are required to investigate and improve dynamic treatments. A deformable phantom capable of testing motion detection and motion mitigation techniques is presented here. The dynamically dEformable Liver PHAntom (ELPHA) was designed to fulfill three main constraints: First, a reproducibly deformable anatomy is required. Second, the phantom should provide multimodality imaging contrast for motion detection. Third, a time-resolved dosimetry system to measure temporal effects should be provided. An artificial liver with vasculature was casted from soft silicone mixtures. The silicones allow for deformation and radiographic image contrast, while added cellulose provides ultrasonic contrast. An actuator was used for compressing the liver in the inferior direction according to a prescribed respiratory motion trace. Electromagnetic (EM) transponders integrated in ELPHA help provide ground truth motion traces. They were used to quantify the motion reproducibility of the phantom and to validate motion detection based on ultrasound imaging. A two-dimensional ultrasound probe was used to follow the position of the vessels with a template-matching algorithm. This detected vessel motion was compared to the EM transponder signal by calculating the root-mean-square error (RMSE). ELPHA was then used to investigate the dose deposition of dynamic treatment deliveries. Two dosimetry systems, radio-chromic film and plastic scintillation dosimeters (PSD), were integrated in ELPHA. The PSD allow for time-resolved measurement of the delivered dose, which was compared to a time-resolved dose of the treatment planning system. Film and PSD were used to investigate dose delivery to the deforming phantom without motion compensation and with treatment-couch tracking for motion compensation. ELPHA showed densities of 66 and 45HU in the liver and the surrounding tissues. A high motion reproducibility with a submillimeter RMSE (<0.32mm) was measured. The motion of the vasculature detected with ultrasound agreed well with the EM transponder position (RMSE<1mm). A time-resolved dosimetry system with a 1Hz time resolution was achieved with the PSD. The agreement of the planned and measured dose to the PSD decreased with increasing motion amplitude: A dosimetric RMSE of 1.2, 2.1, and 2.7cGy/s was measured for motion amplitudes of 8, 16, and 24mm, respectively. With couch tracking as motion compensation, these values decreased to 1.1, 1.4, and 1.4cGy/s. This is closer to the static situation with 0.7cGy/s. Film measurements showed that couch tracking was able to compensate for motion with a mean target dose within 5% of the static situation (-5% to +1%), which was higher than in the uncompensated cases (-41% to -1%). ELPHA is a deformable liver phantom with high motion reproducibility. It was demonstrated to be suitable for the verification of motion detection and motion mitigation modalities. Based on the multimodality image contrast, a high accuracy of ultrasound based motion detection was shown. With the time-resolved dosimetry system, ELPHA is suitable for performance assessment of real-time motion-adaptive radiotherapy, as was shown exemplary with couch tracking.

Similar Papers
  • Research Article
  • Citations19

Validation of dynamic treatment-couch tracking for prostate SBRT

  • Apr 25, 2017
  • Medical Physics
  • Stefanie Ehrbar +6
  • Research Article
  • Citations1

TH-AB-303-01: Benchmarking Real-Time Adaptive Radiotherapy Systems: A Multi- Platform Multi-Institutional Study

  • Jun 01, 2015
  • Medical Physics
  • Emma Colvill +24
  • Research Article

SU‐GG‐T‐287: Deformable Lung Phantom for Verification of 4D Dose Calculations

  • Jun 01, 2008
  • Medical Physics
  • Y Vinogradskiy +3
  • Conference Article
  • Citations24

Intensity-based visual servoing for non-rigid motion compensation of soft tissue structures due to physiological motion using 4D ultrasound

  • Sep 01, 2011
  • Deukhee Lee +1
  • Research Article
  • Citations39

Free‐breathing fetal cardiac MRI with doppler ultrasound gating, compressed sensing, and motion compensation

  • Jun 22, 2019
  • Journal of Magnetic Resonance Imaging
  • Kostas Haris +8
  • Conference Article
  • Citations6

Object Extraction Combining Image Partition with Motion Detection

  • Jan 01, 2007
  • Wenming Yang +2
  • Research Article
  • Citations27

Real-time motion-adaptive-optimization (MAO) in TomoTherapy

  • Jun 23, 2009
  • Physics in Medicine & Biology
  • Weiguo Lu +6
  • Research Article
  • Citations1

Multi-resolution motion estimation and compensation based on adjacent prediction of frame difference in wavelet domain

  • May 01, 2009
  • Journal of Electronics (China)
  • Guowei Tang +1
  • Research Article
  • Citations1

TH-AB-303-03: Real-Time Error Estimation for Real-Time Motion Prediction

  • Jun 01, 2015
  • Medical Physics
  • D Moore +1
  • Research Article
  • Citations3

Motion Detection in Compressed Video Using Macroblock Classification

  • May 31, 2014
  • Advanced Computing: An International Journal
  • M Usha
  • Research Article
  • Citations184

PROPELLER MRI: clinical testing of a novel technique for quantification and compensation of head motion.

  • Aug 23, 2001
  • Journal of Magnetic Resonance Imaging
  • Kirsten P.N Forbes +3
  • PDF
  • Research Article
  • Citations2

Determination of Ocular Artifacts in the Clinical EEG Software by a Peripheral Device

  • Jan 07, 2021
  • Electronics
  • Joanna Górecka +1
  • Research Article
  • Citations3

Multispectral imaging and terrestrial laser scanning for the detection of drought-induced paraheliotropic leaf movement in soybean

  • Dec 01, 2024
  • International Journal of Applied Earth Observation and Geoinformation
  • Erekle Chakhvashvili +7
  • Research Article
  • Citations1

Performance behavior of prediction filters for respiratory motion compensation in radiotherapy

  • Sep 07, 2017
  • Current Directions in Biomedical Engineering
  • Alexander Jöhl +7
  • Preprint Article

Millimeter slope seasonal deformation from multitemporal InSAR with a tropospheric delay correction: a case in Hong Kong

  • May 15, 2023
  • Guoqiang Shi
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.