• Home
  • Search
  • Enhancing sensitivity of high resolution optical coherence tomography using an optional spectrally encoded extended source (Conference Presentation)
  • https://doi.org/10.1117/12.2209287Copy DOI Icon

Enhancing sensitivity of high resolution optical coherence tomography using an optional spectrally encoded extended source (Conference Presentation)

  • Apr 26, 2016
  • Xiaojun Yu +4 more
Show More
  • Abstract
  • Literature Map
  • Similar Papers
Abstract

High-resolution optical coherence tomography (OCT) is of critical importance to disease diagnosis because it is capable of providing detailed microstructural information of the biological tissues. However, a compromise usually has to be made between its spatial resolutions and sensitivity due to the suboptimal spectral response of the system components, such as the linear camera, the dispersion grating, and the focusing lenses, etc. In this study, we demonstrate an OCT system that achieves both high spatial resolutions and enhanced sensitivity through utilizing a spectrally encoded source. The system achieves a lateral resolution of 3.1 μm and an axial resolution of 2.3 μm in air; when with a simple dispersive prism placed in the infinity space of the sample arm optics, the illumination beam on the sample is transformed into a line source with a visual angle of 10.3 mrad. Such an extended source technique allows a ~4 times larger maximum permissible exposure (MPE) than its point source counterpart, which thus improves the system sensitivity by ~6dB. In addition, the dispersive prism can be conveniently switched to a reflector. Such flexibility helps increase the penetration depth of the system without increasing the complexity of the current point source devices. We conducted experiments to characterize the system’s imaging capability using the human fingertip in vivo and the swine eye optic never disc ex vivo. The higher penetration depth of such a system over the conventional point source OCT system is also demonstrated in these two tissues.

Similar Papers
  • Research Article
  • Citations14

Photothermal optical coherence tomography based on the localized surface plasmon resonance of Au nanoring.

  • May 07, 2014
  • Optics Express
  • Ting-Ta Chi +7
  • Conference Article
  • Citations1

All-fiber common-path fourier-domain optical coherence tomography moving 2-axis based on active surface tracking algorithm

  • Sep 01, 2011
  • C G Song +5
  • Conference Article

Motion of organ of Corti structures in the gerbil cochlear apex, measured with a commercial optical coherence tomography (OCT) system

  • Jan 01, 2018
  • AIP conference proceedings
  • Michael E Ravicz +3
  • PDF
  • Abstract

57084 Combining artificial intelligence and robotics: a novel fully automated optical coherence tomography-based approach for eye disease screening

  • Mar 01, 2021
  • Journal of Clinical and Translational Science
  • Ailin Song +8
  • Conference Article

Three-dimensional time and Fourier domain endoscopic OCT using 2-axis scanning MEMS mirror

  • Feb 09, 2006
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Woonggyu Jung +5
  • Conference Article
  • Citations2

Optical coherence tomography for imaging of subpleural alveolar structure using a Fourier domain mode locked laser

  • Jun 09, 2011
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Lars Kirsten +5
  • Conference Article
  • Citations1

Fiber type of optical coherence tomography with auto-focus design

  • May 23, 2005
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Yu-Lung Lo +2
  • Conference Article
  • Citations1

Performance analysis of a full-field and full-range swept-source OCT system

  • Sep 01, 2015
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • J Krauter +8
  • Book Chapter

Optical Coherence Tomography Progression Analysis: Sample Cases

  • Jan 01, 2018
  • Ahmet Akman
  • Conference Article
  • Citations9

Focusing problem in OCT: comparison of Monte-Carlo simulations, the extended Huygens-Fresnel principle, and experiments

  • Apr 28, 2000
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Andreas Tycho +2
  • PDF
  • Research Article
  • Citations44

Optical Coherence Tomography for Three-Dimensional Imaging in the Biomedical Field: A Review

  • Sep 28, 2021
  • Frontiers in Physics
  • Shu Zheng +4
  • Research Article
  • Citations52

Optical coherence tomography-based decision making in exudative age-related macular degeneration: comparison of time- vs spectral-domain devices.

  • Aug 21, 2009
  • Eye (London, England)
  • C Cukras +5
  • Research Article
  • Citations2

Comparative Study of Conventional and Ultrahigh-resolution Optical Coherence Tomography Imaging in Esophageal Neoplasia

  • Jan 01, 2022
  • Techniques and Innovations in Gastrointestinal Endoscopy
  • Hyeon-Cheol Park +5
  • Research Article
  • Citations7

All-fiber ring-cavity based frequency swept laser source for frequency domain OCT

  • Jan 01, 2010
  • Chinese Optics Letters
  • Minghui Chen +6
  • Research Article
  • Citations120

Correlation of quantitative light-induced fluorescence and optical coherence tomography applied for detection and quantification of early dental caries.

  • Jan 01, 2003
  • Journal of Biomedical Optics
  • Bennett T Amaechi +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.