• Home
  • Search
  • Equivalent methods to analyse dynamic experiments in which the input function is noisy
  • Cite Icon11
  • https://doi.org/10.1088/0031-9155/42/1/010Copy DOI Icon

Equivalent methods to analyse dynamic experiments in which the input function is noisy

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

A comparison is made between two methods of parameter estimation for analysis of dynamic experiments in which the input function is noisy. Noise in the input function leads to uncertainties in the calculated model-predicted values, and therefore the covariance matrix of the residuals is a function of the model parameters. Statistical uncertainties in the model-predicted values significantly change the nature of the fitting process and the quality of the results. The initial method uses a weighted least-squares criterion where the weighting matrix is the inverse of the full covariance matrix of the residuals, incorporating both the noise in the output data and the noise in the input function. The methodology was applied to dynamic emission tomography studies of the heart, where the blood (input) and tissue (output) tracer concentrations at each time are derived from two regions of interest in the same tomographic section. The second method introduces additional parameters to describe the input function, and adds terms to the weighted sum of squares which comprise the criterion. Instead of only summing the weighted terms to account for differences between the model and the output function, there is a second set of terms to account for the differences between the model and the input function. The two methods have different theoretical bases and appear to optimize different criteria, but it is shown here that they are equivalent to one another. The criterion which they minimize is the same under certain matrix invertibility constraints, which must be satisfied to ensure the stability of either method.

Similar Papers
  • Research Article

Optimal Sampling Schedule for Both the Input and Output Functions Sampled Simultaneously

  • Mar 01, 1997
  • IFAC Proceedings Volumes
  • Xianjin Li +1
  • Research Article
  • Citations166

A test of a two-stage model of magnitude judgment

  • Jan 01, 1968
  • Perception & Psychophysics
  • Dwight W Curtis +2
  • Research Article
  • Citations2

Assessment of myocardial metabolic rate of glucose by means of Bayesian ICA and Markov Chain Monte Carlo methods in small animal PET imaging

  • Sep 01, 2016
  • Polish Journal of Medical Physics and Engineering
  • Khadidja Berradja +1
  • Research Article
  • Citations93

A method to quantitate cerebral blood flow using a rotating gamma camera and iodine-123 iodoamphetamine with one blood sampling

  • Oct 01, 1994
  • European Journal of Nuclear Medicine
  • Hidehiro Iida +10
  • Research Article
  • Citations35

Artificial intelligence in healthcare: the value co-creation process and influence of other digital health transformations

  • Aug 01, 2023
  • Journal of Research in Interactive Marketing
  • Eric L Swan +2
  • Research Article
  • Citations78

Comparison of methodologies for the in vivo assessment of 18FLT utilisation in colorectal cancer.

  • Nov 14, 2003
  • European Journal of Nuclear Medicine and Molecular Imaging
  • S K Luthra +7
  • PDF
  • Research Article
  • Citations49

Feasibility of using abbreviated scan protocols with population-based input functions for accurate kinetic modeling of [18F]-FDG datasets from a long axial FOV PET scanner

  • Oct 04, 2022
  • European Journal of Nuclear Medicine and Molecular Imaging
  • Hasan Sari +9
  • PDF
  • Research Article
  • Citations2

Combining MRI with PET for partial volume correction improves image-derived input functions in mice.

  • Jul 29, 2014
  • EJNMMI Physics
  • Eleanor Evans +8
  • Book Chapter
  • Citations2

Chapter 48 - Simultaneous Extraction of Physiological and Input Function Parameters from PET Measurements

  • Jan 01, 1998
  • Quantitative Functional Brain Imaging with Positron Emission Tomography
  • Dagan Feng +3
  • Conference Article

Factor analysis and kinetic modeling for PET: are they relevant for clinical applications?

  • Jan 01, 2007
  • Christiaan Schiepers +2
  • Research Article
  • Citations96

Quantitative analysis of regional airways obstruction using dynamic hyperpolarized 3He MRI—Preliminary results in children with cystic fibrosis

  • Aug 15, 2005
  • Journal of Magnetic Resonance Imaging
  • Panos Koumellis +8
  • Research Article
  • Citations19

Using the spleen for time-delay correction of the input function in measuring hepatic blood flow with oxygen-15 water by dynamic PET.

  • Aug 01, 1999
  • Annals of Nuclear Medicine
  • Hiroki Taniguchi +7
  • Research Article
  • Citations11

Maximizing precision in quantitative autoradiographic determination of tissue tracer concentration using exposure optimization.

  • Aug 01, 1986
  • Journal of Cerebral Blood Flow & Metabolism
  • James L Lear
  • Research Article
  • Citations34

Efficient Delay Correction for Total-Body PET Kinetic Modeling Using Pulse Timing Methods.

  • Dec 21, 2021
  • Journal of Nuclear Medicine
  • Elizabeth J Li +6
  • Conference Article

Realization of Online Intelligent Platform Matlab of Three-Round Education Mechanism in Universities Under the Environment of Multi-Dimensional Information Technology

  • Sep 21, 2022
  • Peixun Wang
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.