• Home
  • Search
  • Error identification in a high-volume clinical chemistry laboratory: Five-year experience
  • Cite Icon13
  • https://doi.org/10.3109/00365513.2015.1010175Copy DOI Icon

Error identification in a high-volume clinical chemistry laboratory: Five-year experience

  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Introduction. Quality indicators for assessing the performance of a laboratory require a systematic and continuous approach in collecting and analyzing data. The aim of this study was to determine the frequency of errors utilizing the quality indicators in a clinical chemistry laboratory and to convert errors to the Sigma scale. Materials and methods. Five-year quality indicator data of a clinical chemistry laboratory was evaluated to describe the frequency of errors. An ‘error’ was defined as a defect during the entire testing process from the time requisition was raised and phlebotomy was done until the result dispatch. An indicator with a Sigma value of 4 was considered good but a process for which the Sigma value was 5 (i.e. 99.977% error-free) was considered well controlled. Results. In the five-year period, a total of 6,792,020 specimens were received in the laboratory. Among a total of 17,631,834 analyses, 15.5% were from within hospital. Total error rate was 0.45% and of all the quality indicators used in this study the average Sigma level was 5.2. Three indicators – visible hemolysis, failure of proficiency testing and delay in stat tests – were below 5 on the Sigma scale and highlight the need to rigorously monitor these processes. Conclusions. Using Six Sigma metrics quality in a clinical laboratory can be monitored more effectively and it can set benchmarks for improving efficiency.

Similar Papers
  • Research Article
  • Citations5

Six Sigma Metrics: An Evolving Indicator of Quality Assurance for Clinical Biochemistry

  • Jan 01, 2022
  • JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH
  • Devi Prasad Pradhan +4
  • Research Article
  • Citations1

Sigma metrics – a good quality control guide to assess analytical performance of a clinical chemistry laboratory

  • Jul 01, 2024
  • Asian Journal of Medical Sciences
  • Lincy Raj C +2
  • Research Article

External quality assessment of clinical laboratory quality indicators in China in 2015

  • Jun 11, 2016
  • Chinese Journal of Laboratory Medicine
  • Fei Yang +6
  • Research Article

Evaluation of clinical biochemical laboratory analytical process performance using sigma metrics and quality goal index

  • Dec 30, 2021
  • Chinese Journal of Medical Research
  • Rogious Mbasani +2
  • Research Article
  • Citations8

Impact of COVID-19 on the pre and post analytical clinical laboratory testing processes- A performance evaluation study using six sigma

  • Sep 09, 2021
  • Annals of Medicine and Surgery
  • Sibtain Ahmed +3
  • PDF
  • Research Article
  • Citations12

The application of sigma metrics in the laboratory to assess quality control processes in South Africa

  • Jun 22, 2022
  • African Journal of Laboratory Medicine
  • Marli Van Heerden +2
  • PDF
  • Research Article
  • Citations12

Application of sigma metrics for the assessment of quality assurance using the MQ-2000 PT HbA1c analyzer.

  • Jan 01, 2015
  • Biochemia Medica
  • Kağan Huysal +1
  • Research Article
  • Citations4

Evaluation of quality indicators in pre-analytical phase of testing in clinical biochemistry laboratory of a tertiary care hospital in India

  • Sep 15, 2020
  • International Journal of Clinical Biochemistry and Research
  • Nishtha Wadhwa
  • Research Article

A-062 Development of Quality Control Indicators in the Pre-analytical Phase and a Survey on the Current Status of Clinical Laboratories in Korea

  • Sep 27, 2023
  • Clinical Chemistry
  • H Park +4
  • Research Article
  • Citations1

Preanalytical Quality in Clinical Chemistry Laboratory

  • Jan 01, 2013
  • Clinical Laboratory
  • M Imteyaz Ahmad +2
  • Research Article
  • Citations40

Plasma levels and tricyclic antidepressant therapy: Part 2 Pharmacokinetic, clinical and toxicologic aspects.

  • Oct 01, 1980
  • Biopharmaceutics & Drug Disposition
  • G Molnar +1
  • Research Article
  • Citations3

Determination of errors that compromise the quality of laboratory service in a tertiary hospital

  • Jan 03, 2017
  • Asian Journal of Medical Sciences
  • Kenneth Kipruto Kimengech +3
  • Research Article
  • Citations49

Quality in laboratory medicine: 50 years on

  • Oct 17, 2016
  • Clinical Biochemistry
  • Mario Plebani
  • Research Article
  • Citations4

Self assessment of pre, intra and post analytical errors of urine analysis in Clinical Chemistry Laboratory of Alexandria Main University Hospital

  • Jan 01, 2014
  • Saudi Journal for Health Sciences
  • Nermine Hossam +3
  • Research Article
  • Citations10

Sigma Metrics: A Valuable Tool for Evaluating the Performance of Internal Quality Control in Laboratory.

  • Jun 28, 2021
  • Journal of Laboratory Physicians
  • Akriti Kashyap +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.