• Home
  • Search
  • Estimating the Accuracy Level Among Individual Detections in Clustered Microcalcifications.
  • Open Access IconOpen Access
  • Cite Icon13
  • https://doi.org/10.1109/tmi.2017.2654799Copy DOI Icon

Estimating the Accuracy Level Among Individual Detections in Clustered Microcalcifications.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Computerized detection of clustered microcalcifications (MCs) in mammograms often suffers from the occurrence of false positives (FPs), which can vary greatly from case to case. We investigate how to apply statistical estimation to determine the number of FPs that are present in a detected MC lesion. First, we describe the number of true positives (TPs) by a Poisson-binomial probability distribution, wherein a logistic regression model is trained to determine the probability for an individual detected MC to be a TP based on its detector output. Afterward, we model the spatial occurrence of FPs in a lesion area by a spatial point process (SPP), of which the distribution parameters are estimated from the detections in the lesion and its surrounding region. Furthermore, to improve the estimation accuracy, we incorporate the Poisson-binomial distribution of the number of TPs into the SPP model using maximum a posteriori estimation. In the experiments, we demonstrated the proposed approach on the detection results from a set of 188 full-field digital mammography (FFDM) images (95 cases) by three existing MC detectors. The results showed that there was a strong consistency between the estimated and the actual number of TPs (or FPs) for these detectors. When the fraction of FPs in detection was varied from 20% to 50%, both the mean and median values of the estimation error were within 11% of the total number of detected MCs in a lesion. In particular, when the number of FPs increased to as high as 11.38 in a cluster on average, the error was 2.51 in the estimated number of FPs. In addition, lesions estimated to be more accurate in detection were shown to have better classification accuracy (for being malignant or benign) than those estimated to be less accurate.

Similar Papers
  • Front Matter
  • Citations1

Time for Change in Digital Breast Tomosynthesis Research.

  • Nov 09, 2021
  • Radiology
  • Daniel B Kopans
  • Research Article
  • Citations12

Full-Field Digital Mammographic Interpretation With Prior Analog Versus Prior Digitized Analog Mammography: Time for Interpretation

  • Jun 01, 2011
  • American Journal of Roentgenology
  • Akshay S Garg +6
  • Conference Article

A Proposed Figure of Merit for Evaluating the Performance of Radiation Waste Measurement Systems

  • Jan 01, 2011
  • Ronald M Keyser +3
  • Research Article
  • Citations17

MLN-net: A multi-source medical image segmentation method for clustered microcalcifications using multiple layer normalization

  • Nov 02, 2023
  • Knowledge-Based Systems
  • Ke Wang +5
  • Conference Article
  • Citations1

Adaboost with dummy-variable modeling for reduction of false positives in detection of clustered microcalcifications

  • Oct 01, 2014
  • Juan Wang +1
  • Research Article

BEYOND THE PIXEL: CAN SYNTHETIC 2D MAMMOGRAPHY DELIVER WHAT DIGITAL CAN'T

  • Oct 01, 2025
  • INDIAN JOURNAL OF APPLIED RESEARCH
  • T Sethi +5
  • Conference Article
  • Citations4

Methodology for the objective assessment of lesion detection performance with breast tomosynthesis and digital mammography using a physical anthropomorphic phantom

  • Mar 09, 2018
  • Medical Imaging 2018: Physics of Medical Imaging
  • Lynda C Ikejimba +7
  • PDF
  • Research Article
  • Citations5

Three-Dimensional Computer-Aided Detection of Microcalcification Clusters in Digital Breast Tomosynthesis

  • Jan 01, 2016
  • BioMed Research International
  • Ji-Wook Jeong +5
  • Conference Article

Advancing synthetic mammography for stationary digital breast tomosynthesis

  • Mar 16, 2020
  • Medical Imaging 2020: Physics of Medical Imaging
  • Connor Puett +4
  • Research Article
  • Citations104

Massive‐training artificial neural network (MTANN) for reduction of false positives in computer‐aided detection of polyps: Suppression of rectal tubes

  • Sep 25, 2006
  • Medical Physics
  • Kenji Suzuki +3
  • Research Article
  • Citations16

Detection of noncalcified breast cancer in patients with extremely dense breasts using digital breast tomosynthesis compared with full-field digital mammography.

  • Oct 03, 2018
  • The British journal of radiology
  • Ann Yi +6
  • Book Chapter
  • Citations12

Self-adversarial Learning for Detection of Clustered Microcalcifications in Mammograms

  • Jan 01, 2021
  • Xi Ouyang +8
  • Research Article
  • Citations77

Visibility of microcalcification in cone beam breast CT: effects of X-ray tube voltage and radiation dose.

  • Jun 26, 2007
  • Medical physics
  • Chao-Jen Lai +9
  • Research Article
  • Citations23

Recall Rate Reduction with Tomosynthesis During Baseline Screening Examinations: An Assessment From a Prospective Trial

  • Sep 26, 2015
  • Academic Radiology
  • Jules H Sumkin +8
  • Conference Article
  • Citations14

Reduction of false positive detection in clustered microcalcifications

  • Sep 01, 2013
  • Juan Wang +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.