Abstract

South African laboratories are currently using various methods in a non-standardised approach to detect Legionella species in environmental samples. In an attempt to provide guidelines for the development of a standard method, a number of currently available detection methods were evaluated, using seeded samples of sterile and non-sterile tap water, cooling water and make-up water. The samples were seeded with a type strain of L. pneumophila serogroup 1 (American Type Culture Collection 33152). The effect of sample concentration by centrifugation and membrane filtration followed by either vortex or sonication for resuspension of organisms was studied. Three currently available culture methods were evaluated: the International standard method (ISO/DIS 11731), the Australian standard method (AS 3896 - 1991) and a locally-developed adaptation of the most probable number method (MPN). In addition, the direct immunofluorescence test and a commercially available latex agglutination test kit were included in the evaluations. The usefulness of treatment with acid or heat prior to culture was also compared. Our results indicated that concentration by membrane filtration using nitro-cellulose filters with a pore size of 0.45 ?m, followed by sonication for 10 min, would be the most appropriate concentration and resuspension method for the samples. In the absence of sample pretreatment with acid or heat, organism recovery from sterile seeded samples on BCYE ranged from 85.9 - 98.7%. However, in the non-sterile samples, these figures dropped to 8.1 - 38.5%. Sample pretreatment resulted in a further loss of at least 50% of organisms in all the samples, regardless of the pretreatment method or culture medium used. In general, the ISO and AS methods were more appropriate than the MPN method for organism recovery from sterile seeded samples. However, for the nonsterile samples, the MPN method yielded better recovery. WaterSA Vol.27(4) 2001: 523-528

Similar Papers
  • Book Chapter
  • Citations2

Standard XRF Analytical Methods for the Mining, Mineral Processing and Metallurgy Industry

  • Jan 01, 1995
  • Advances in X-ray Analysis
  • S. L. Birch +2
  • Research Article

Recovery of coliform bacteria from freshwaters ‐ comparison of multiple tube and membrane filter techniques

  • Nov 01, 1988
  • Environmental Technology Letters
  • S.K Shishodia +1
  • Research Article
  • Citations49

Use of bacterial spores in monitoring water quality and treatment.

  • Apr 30, 2018
  • Journal of Water and Health
  • Gerard N Stelma
  • Research Article
  • Citations14

Improving Salmonella determination in Sinaloa rivers with ultrafiltration and most probable number methods

  • Jul 29, 2011
  • Environmental Monitoring and Assessment
  • Maribel Jimenez +1
  • Conference Article

Microbial Assessment and Control in Drilling Operations

  • Jan 29, 2018
  • Mohammed E Sindi +6
  • Research Article
  • Citations12

Binding of prolactin and monoclonal antibody to prolactin receptors immobilized on a nitrocellulose membrane filter

  • Dec 01, 1987
  • Analytical Biochemistry
  • Senkiti Sakai +1
  • Research Article

Assessment of physicochemical and antibacterial properties of structured water samples from Ota, Ogun State, Nigeria

  • Mar 01, 2025
  • Scientific African
  • Abiodun H Adebayo +3
  • Discussion
  • Citations51

Legionella Pneumonia and AIDS

  • Mar 01, 1989
  • Chest
  • Azmy A Allam +1
  • Research Article
  • Citations34

Legionella Gratiana sp Nov. isolated from French SPA water

  • Jan 01, 1989
  • Research in Microbiology
  • N Bornstein +11
  • Research Article
  • Citations1

Analysis of crude glycerin by the international standard methods, 1911

  • Nov 29, 1913
  • Journal of the Society of Chemical Industry
  • R G Grimwood
  • Research Article
  • Citations23

Retrospective examination of lung tissue specimens for the presence of Legionella organisms: comparison of an indirect fluorescent-antibody system with direct fluorescent-antibody testing.

  • Apr 01, 1984
  • Journal of clinical microbiology
  • S L Brown +2
  • Research Article
  • Citations10

Legionella pneumophila associada a insuficiência respiratória aguda: primeiro isolamento no Brasil

  • Dec 01, 1989
  • Revista do Instituto de Medicina Tropical de São Paulo
  • João Carlos Pereira Gomes +3
  • Research Article
  • Citations3

Impact of Improved Sanitation Standard Operating Procedures on Microbial Populations at Three Tree Fruit Packing Facilities.

  • Jan 01, 2025
  • Journal of food protection
  • M Laura Rolon +5
  • Research Article
  • Citations5

An annual cycle of abundance and activity of heterotrophic bacteria and abundance of hydrocarbonoclastic bacteria in Newfoundland coastal water

  • May 01, 1987
  • Canadian Journal of Microbiology
  • James C Powell +2
  • Research Article
  • Citations3

Role of Polyphosphate Kinase Gene (ppk) for Survival of Vibrio cholerae O1 in Surface Water of Bangladesh

  • Nov 01, 2013
  • Pakistan Journal of Biological Sciences
  • Iqbal Kabir Jahid +6
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.