Abstract

Semiconductor photon-counting detectors based on high atomic number, high density materials [cadmium zinc telluride (CZT)/cadmium telluride (CdTe)] for x-ray computed tomography (CT) provide advantages over conventional energy-integrating detectors, including reduced electronic and Swank noise, wider dynamic range, capability of spectral CT, and improved signal-to-noise ratio. Certain CT applications require high spatial resolution. In breast CT, for example, visualization of microcalcifications and assessment of tumor microvasculature after contrast enhancement require resolution on the order of [Formula: see text]. A straightforward approach to increasing spatial resolution of pixellated CZT-based radiation detectors by merely decreasing the pixel size leads to two problems: (1)fabricating circuitry with small pixels becomes costly and (2)inter-pixel charge spreading can obviate any improvement in spatial resolution. We have used computer simulations to investigate position estimation algorithms that utilize charge sharing to achieve subpixel position resolution. To study these algorithms, we model a simple detector geometry with a [Formula: see text] array of [Formula: see text] pixels, and use a conditional probability function to model charge transport in CZT. We used COMSOL finite element method software to map the distribution of charge pulses and the Monte Carlo package PENELOPE for simulating fluorescent radiation. Performance of two x-ray interaction position estimation algorithms was evaluated: the method of maximum-likelihood estimation and a fast, practical algorithm that can be implemented in a readout application-specific integrated circuit and allows for identification of a quadrant of the pixel in which the interaction occurred. Both methods demonstrate good subpixel resolution; however, their actual efficiency is limited by the presence of fluorescent [Formula: see text]-escape photons. Current experimental breast CT systems typically use detectors with a pixel size of [Formula: see text], with [Formula: see text] binning during the acquisition giving an effective pixel size of [Formula: see text]. Thus, it would be expected that the position estimate accuracy reported in this study would improve detection and visualization of microcalcifications as compared to that with conventional detectors.

Similar Papers
  • Conference Article

Dual anode contact geometries for x-ray and gamma-ray spectroscopy and 3D localization

  • Aug 20, 2009
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • J W Martin +7
  • Research Article
  • Citations1

TH-A-217BCD-03: Spectral Distortion Correction for Photon-Counting X-Ray Detectors

  • Jun 01, 2012
  • Medical Physics
  • H Ding +1
  • Book Chapter

Anthropomorphic breast phantom production with 3D printer technique to find more accurate factors for average glandular dose calculation

  • Jan 01, 2025
  • Research Article
  • Citations200

Abdominal Imaging with Contrast-enhanced Photon-counting CT: First Human Experience.

  • Feb 03, 2016
  • Radiology
  • Amir Pourmorteza +9
  • Research Article
  • Citations2

Characterisation of Portuguese radiotherapy departments: Organisation, occupational exposure values and diagnostic reference levels for breast and prostate computed tomography planning

  • Apr 23, 2024
  • Radiography (London, England : 1995)
  • Rafaela Guisantes +2
  • Research Article
  • Citations8

Nanoparticles: Untying the Gordian Knot in Conventional Computed Tomography Imaging

  • May 11, 2021
  • CCS Chemistry
  • Zhen Sun +5
  • Research Article
  • Citations49

Personalized estimates of radiation dose from dedicated breast CT in a diagnostic population and comparison with diagnostic mammography

  • Oct 29, 2013
  • Physics in Medicine and Biology
  • Srinivasan Vedantham +4
  • Conference Article
  • Citations100

First results from a hybrid prototype CT scanner for exploring benefits of quantum-counting in clinical CT

  • Feb 23, 2012
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • S Kappler +6
  • Research Article

In-breast tumor recurrence rate of breast CT-guided lumpectomy: A prospective multi-institutional study in Japan.

  • Sep 20, 2012
  • Journal of Clinical Oncology
  • Nobuaki Sato
  • Research Article
  • Citations18

Improving the spatial resolution in CZT detectors using charge sharing effect and transient signal analysis: Simulation study

  • Nov 20, 2015
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • Xiaoqing Zheng +3
  • Research Article
  • Citations51

Breast Ct: Potential For Breast Cancer Screening and Diagnosis

  • Jun 20, 2006
  • Future Oncology
  • John M Boone +1
  • Research Article
  • Citations14

Demonstration of multiple contrast agent imaging for the next generation color X-ray CT

  • Sep 19, 2019
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • T Maruhashi +9
  • Conference Article
  • Citations6

CdZnTe bulk crystal growth and temperature modeling studies at METU-CGL

  • Sep 13, 2018
  • Özden B Balbasi +6
  • Research Article
  • Citations51

Semiconductor materials for x-ray detectors

  • Jun 01, 2017
  • MRS Bulletin
  • David Pennicard +3
  • PDF
  • Research Article
  • Citations33

An Unsupervised Automatic Segmentation Algorithm for Breast Tissue Classification of Dedicated Breast Computed Tomography Images

  • May 09, 2018
  • Medical physics
  • Marco Caballo +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.