Abstract

This paper generalizes the modelling of 132kV transmission line design for the purpose of backflashover simulation using the Electromagnetic Transient Program that is Power System Computer Aided Design (PSCAD) software. Sample of transmission line data was taken from Tenaga National Berhad (TNB) for the purpose of simulation using PSCAD software. Crucial part of the studies include the model of transmission line components such as insulator coordination, tower model, tower footing model and surge arrester. This research will focus on the effect of different position of transmission line surge arrester placement at transmission line to the value of backflashover rate. A model of surge arrester is implemented using PSCAD software and was located across the line insulation, to prevent flashover. The capabilities of arrester in reducing backflashover rate are investigated so that the proper arrester rating can be selected for any system requirement. Results were analyzed and the influence of transmission line surge arrester placement to backflashover rate at transmission line was discussed. Findings from this research can be a significant modelling guideline to the transmission line designers or other researchers to improve the performance of overhead transmission line in term of reducing the backflashover rate.

Similar Papers
  • Research Article
  • Citations3

Examination of Gas Active Arc Extinguishing and Lightning Protection for Transmission Lines

  • Sep 01, 2023
  • Journal of Progress in Engineering and Physical Science
  • S L Braide
  • Conference Article
  • Citations6

Investigation on the effects of line parameters to the lightning performance of 132 kV Kuala Krai-Gua Musang transmission line

  • Jun 01, 2013
  • J Sardi +1
  • Research Article

MODELLING AND ANALYSES OF OVER-VOLTAGE IN 400 KV OVERHEAD TRANSMISSION LINE CAUSED BY LIGHTNING STRIKE

  • Sep 20, 2021
  • Journal of Engineering and Sustainable Development
  • Rua'A S Rashak +1
  • Conference Article
  • Citations3

Investigation of Various Faults of 500 kV Transmission Line Design in Sarawak, Malaysia Using Power Systems Computer Aided Design

  • Sep 10, 2022
  • Yanuar Z Arief +5
  • Research Article
  • Citations68

A Practical Evaluation of Surge Arrester Placement for Transmission Line Lightning Protection

  • Jul 01, 2010
  • IEEE Transactions on Power Delivery
  • Karthik Munukutla +4
  • PDF
  • Research Article
  • Citations8

A Methodology for Optimal Design of Transmission Lines to Protection against Lightning Surges in Presence of Arresters

  • Jul 05, 2020
  • Advanced Electromagnetics
  • R Shariatinasab +1
  • PDF
  • Research Article
  • Citations1

A New Principle of Distance Protection for the UHV GIL-Overhead Hybrid Line Based on Frequency Domain Lossless Transmission Line Equation

  • Nov 25, 2019
  • Energies
  • Botong Li +4
  • Book Chapter
  • Citations7

Estimation of the Minimum Backflashover Current of 150 and 400 kV Overhead Transmission Lines Through ATP-EMTP Simulations: Effect of the Lightning Stroke Location Along Line Spans

  • Nov 28, 2019
  • Z G Datsios +4
  • Research Article
  • Citations1

Detection of Electromechanical Wave Propagation Using Synchronized Phasor Measurements

  • Jan 14, 2014
  • International Journal of Emerging Electric Power Systems
  • Prakash Suryawanshi +2
  • Research Article
  • Citations3

Analysis of Lightning Surge Condition Effect on Surge Arrester in Electrical Power System by using ATP/EMTP Program

  • Apr 29, 2007
  • Zenodo (CERN European Organization for Nuclear Research)
  • Narong Mungkung +4
  • Conference Article
  • Citations4

An Efficient Surge Arrester Placement Strategy to Improve the Lightning Performance of Long Transmission Line

  • Aug 02, 2020
  • Qianxue Xia +1
  • Research Article
  • Citations2

Analysis and comparison of metal-oxide surge arrester models

  • Nov 30, 2017
  • Technology audit and production reserves
  • Volodymyr Brzhezitsky +2
  • PDF
  • Research Article
  • Citations6

Monte Carlo Evaluation of the Impact of Subsequent Strokes on Backflashover Rate

  • Feb 26, 2016
  • Energies
  • Fabio Gatta +3
  • Conference Article
  • Citations4

Lightning outage transmission line reliability improvement with surge arresters

  • May 01, 2016
  • C Romualdo-Torres +2
  • Research Article
  • Citations8

Lightning Performance Analysis of an Overhead Transmission Line Protected by Surge Arresters

  • Mar 01, 2009
  • IEEE Latin America Transactions
  • Juan A Martinez +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.