• Home
  • Search
  • Experience with ISO-Paraffinic Insulating Oil for Power Transformers
  • Cite Icon1
  • https://doi.org/10.1109/ichve.2018.8642183Copy DOI Icon

Experience with ISO-Paraffinic Insulating Oil for Power Transformers

  • Sep 1, 2018
  • W Mcdermid +2 more
Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

For many years Manitoba Hydro had used naphthenic oil refined by solvent extraction and hydrogen treatment in its power transformers. The oil purchased in 1960 through 1979 contained no more than 0.08% oxidation inhibitor. By 1990 naphthenic oil was specified as having at least 0.15% and not more than 0.4% oxidation inhibitor. However, during the 1990s insulating oil meeting this description experienced premature ageing under conditions of service. This resulted in the need to reclaim using Fuller's Earth or replace with new the oil in a number of large generator step-up transformers after less than 10 years of service. The unsatisfactory experience caused us to evaluate more reliable sources of insulating oil. Since 1999 Manitoba Hydro has used a synthesized iso-paraffinic insulating oil in new generator step-up, HVDC converter, and transmission transformers. This choice was made as a result of the improved oxidation stability and heat transfer capabilities of this fluid. In addition, the selected iso-paraffinic oil has low kinematic viscosity at -40°C which is a vital requirement in our climate. As many of these transformers installed since 1999 have been in service for at least 10 years, this paper tracks the results of insulating oil quality tests on typical units based on measurements of colour, interfacial tension, acidity, and dissipation factor. Other diagnostic tests involving the oil have included dielectric strength, water content, dissolved gas-in-oil and furan-in-oil. Manitoba Hydro participated in thermal ageing tests sponsored by CEATI on a number of small transformers filled with two types of naphthenic oil as well as the iso-paraffinic oil. These tests confirmed the superior performance of the iso-paraffinic oil compared to that of a commonly used naphthenic oil.

Similar Papers
  • Research Article
  • Citations15

Analysis of a generator step-up transformer failure following faulty synchronization

  • Jul 01, 1988
  • IEEE Transactions on Power Delivery
  • B.M Pasternack +2
  • Research Article

Optimizing nonutility generating facility reactive power capability

  • Jan 01, 2000
  • IEEE Industry Applications Magazine
  • G.J Nolan +1
  • Research Article

A numerical study on effect of intra and inter spaced winding configuration on performance of oil forced transformer cooling system

  • Jan 12, 2024
  • Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
  • Yamala Muralikrishna +3
  • Research Article
  • Citations2

Applying CTs with digital ground relays

  • Jan 01, 2001
  • IEEE Industry Applications Magazine
  • P.E Sutherland
  • Conference Article

Implementation of a Blackstart cranking path sequence operation through PMU

  • Oct 28, 2025
  • Chirag Mistry +3
  • Research Article
  • Citations8

Improvement of thermal performance of generator step-up transformers

  • Dec 27, 2014
  • Applied Thermal Engineering
  • Robert Sitar +2
  • Single Report

Informing Transmission Supply Chain Needs from National Transmission Studies

  • Mar 06, 2026
  • Amy Rose +4
  • Conference Article
  • Citations10

On line reclamation of aged transformer oils

  • Oct 16, 2001
  • J Sabau
  • Research Article
  • Citations23

The behavior of water in XLPE and EPR cables and its influence on the electric characteristics of insulation

  • Jan 01, 1999
  • IEEE Transactions on Power Delivery
  • S.V Nikolajevic
  • Research Article
  • Citations1

Optimization on Control Strategy of Tap Changer in HVDC Converter Transformer

  • Feb 09, 2021
  • Electric Power Construction
  • Xianshan Guo +4
  • Research Article
  • Citations64

Dielectric properties of transformer oils for HVDC applications

  • Dec 01, 2012
  • IEEE Transactions on Dielectrics and Electrical Insulation
  • Lijun Yang +3
  • Research Article
  • Citations1

Dielectric spectroscopy study of hydrogen treated lead zirconate titanate (Pb (Zr,Ti)O3)

  • Mar 01, 2013
  • physica status solidi (a)
  • A Shafiei +1
  • Conference Article
  • Citations19

Detection of oil-pressboard insulation aging with dielectric spectroscopy in time and frequency domain measurements

  • Jul 05, 2004
  • O Hassan +5
  • Research Article
  • Citations3

Selection of Generator Stepup Transformer Ratings

  • Jul 01, 1981
  • IEEE Transactions on Power Apparatus and Systems
  • A.W Goldman
  • Research Article
  • Citations25

Low Energy Degradation Triangle for power transformer health assessment

  • Feb 01, 2017
  • IEEE Transactions on Dielectrics and Electrical Insulation
  • N Moodley +1
Cactus Communications logo