Abstract

In bone conduction (BC) hearing, sound is transmitted directly to the cochlea via skull vibrations, bypassing the outer and middle ear. This provides a therapeutic option for patients with conductive or mixed hearing loss and single-sided deafness. Although finite-element models have advanced understanding of the mechanisms underlying BC, progress toward personalized treatment strategies remains limited by a lack of standardized, experimentally validated, subject-specific models. This study proposes a hierarchical validation framework to support the development and validation of individualized computational models of the human head under BC stimulation. The framework spans four anatomical levels: system, subsystems, structures, and tissues. This approach enables systematic acquisition of data from intact cadaver heads down to isolated material domains. To demonstrate the applications of the framework, an experimental study was conducted on a single cadaver head, targeting three levels: the intact head (system), extracted bone pieces (structures), and isolated cortical layers (tissues). Subsystems were not addressed. High-resolution photon-counting computed tomography (CT) and energy-integrating cone-beam CT were used to acquire anatomical data. One-dimensional laser Doppler vibrometry was used to capture vibrational responses of bone pieces and cortical layers under wet and dry conditions. Representative results were analyzed to assess the impact of preparation state on resonance behavior. Comparative analysis showed that photon-counting CT provided superior structural resolution compared with energy-integrating cone-beam CT, particularly at the full-head (system) level. Vibrational measurements at the structure and tissue levels from the same anatomical region revealed broadly consistent resonance vibration patterns, enabling comparison of resonance frequencies. The influence of hydration state and thickness reduction on vibrational behavior was highlighted. The proposed framework provides a scalable methodology for validation of subject-specific BC models with the potential for more accurate BC simulations based on the hypothesis of functional variability rooted in anatomical variability. Obvious use cases would include the development of improved hearing aid designs and personalized treatments. In parallel, a successful correlation of anatomical and functional variability can serve as inspiration for design principles of metamaterials.

Similar Papers
  • Research Article
  • Citations37

Binaural Hearing Ability With Bilateral Bone Conduction Stimulation in Subjects With Normal Hearing: Implications for Bone Conduction Hearing Aids.

  • Nov 01, 2016
  • Ear & Hearing
  • Mehrnaz Zeitooni +2
  • Research Article
  • Citations20

A comparison study of audiological outcome and compliance of bone conduction implantable hearing implants.

  • May 13, 2020
  • European Archives of Oto-Rhino-Laryngology
  • Jae Joon Han +4
  • PDF
  • Research Article
  • Citations19

Cervical vestibular evoked myogenic potentials in healthy children: Normative values for bone and air conduction

  • Apr 18, 2023
  • Frontiers in Neurology
  • Sylvette R Wiener-Vacher +3
  • Research Article
  • Citations90

Safety and effectiveness of the Bonebridge transcutaneous active direct-drive bone-conduction hearing implant at 1-year device use.

  • Jul 30, 2016
  • European Archives of Oto-Rhino-Laryngology
  • Sébastien Schmerber +13
  • Research Article
  • Citations1

A Non-Surgical Wearable Option for Bone Conduction Hearing Implants: A Comparative Study with Conventional Bone Conduction Hearing Aids Mounted on Eyeglasses

  • Oct 11, 2024
  • Audiology Research
  • Federica Di Berardino +6
  • Research Article
  • Citations1

3D finite element modeling of earplug-induced occlusion effect in the human ear

  • Jun 10, 2024
  • Medical Engineering and Physics
  • John J Bradshaw +3
  • Research Article
  • Citations34

DSL prescriptive targets for bone conduction devices: adaptation and comparison to clinical fittings

  • Mar 27, 2017
  • International Journal of Audiology
  • William E Hodgetts +1
  • Research Article
  • Citations1

Externalization of Virtual Sound Sources With Bone and Air Conduction Stimulation.

  • Feb 01, 2025
  • Trends in hearing
  • Jie Wang +5
  • Research Article
  • Citations1

The Bonebridge BCI 602 Safety and Performance 1 Year Post-Implantation in Adults and Children: A Multicentric Post-Market Study

  • Nov 18, 2025
  • Otology & Neurotology
  • Stefan K Plontke +21
  • Research Article

Rehabilitation of Hearing Function With Active Devices Bonebridge and Vibrant Soundbridge

  • Dec 27, 2025
  • Medicina Moderna - Modern Medicine
  • Iurie Noroc +2
  • Research Article
  • Citations7

Semi-implantable transcutaneous bone conduction hearing devices

  • Jul 01, 2014
  • HNO
  • R Siegert +1
  • Research Article
  • Citations20

VEMP using a new low-frequency bone conduction transducer

  • Sep 06, 2018
  • Medical Devices (Auckland, N.Z.)
  • Bo Håkansson +7
  • Research Article
  • Citations82

Round window membrane motion with air conduction and bone conduction stimulation

  • Sep 11, 2004
  • Hearing Research
  • Stefan Stenfelt +2
  • Research Article
  • Citations3

Performance With an Adhesive Bone Conduction Device in Active Transcutaneous Bone Conduction Implant Users.

  • Jan 13, 2021
  • Otology & Neurotology
  • Valerie Dahm +7
  • Book Chapter
  • Citations62

An Overview of Different Systems: The Bone-Anchored Hearing Aid

  • Jan 01, 2011
  • Catharina A.J Dun +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.