• Home
  • Search
  • Experimental researching of biological objects noninvasive passive acoustothermometry features
  • Open Access IconOpen Access
  • Cite Icon6
  • https://doi.org/10.15587/1729-4061.2020.192594Copy DOI Icon

Experimental researching of biological objects noninvasive passive acoustothermometry features

Show More
  • Abstract
  • Highlights & Summary
  • PDF
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Experimental confirmation of the possibility of real-time measurement of the internal (deep) temperature of a biological object by thermal acoustic radiation with an accuracy of at least 0.2 °C using an acoustic thermometer implementing the modified zero modulation method is obtained. The model of a single-channel passive noninvasive focussed acoustic thermometer based on a plate piezoceramic electro-acoustic transducer, acoustic elliptical lens and blocks of two serial voltmeters is developed. Electronic switching of the output signals of the noise simulator and the equivalent circuit of the focused piezoelectric transducer is proposed, when resistance generates thermal noise with an intensity equal to the sum of intensities of acoustic radiation of the biological object and natural noise of the piezoelectric transducer. This circuitry solution made it possible to exclude the mechanical modulator (shutter) unit used in analogs from the acoustic thermometer circuit. When developing the original switching and detection unit, it was proposed to use the key mode of n-channel field-effect transistors to perform modulation of the input noise signal. Calculation of equivalent circuits of the piezoelectric electroacoustic transducer and noise simulator, which are connected circuits with a bandwidth in which the average noise voltage level is determined by the noise voltage at the electric resonance frequency of the piezoelectric element, is performed. The possibility of using the model of the single-channel passive noninvasive focussed acoustic thermometer, constructed according to the circuit implementing the modified zero modulation method, for measuring noise voltages in the range from 5 to 30 μV is proved. Since the process of manufacturing or operating a piezoceramic electroacoustic transducer may lead to a deviation of its parameters from theoretically calculated, a method is developed to measure the frequency response of the active and reactive components of electrical impedance. Using the proposed method, the assembly quality of the focused piezoelectric electro-acoustic transducer is monitored and the temperature dependence of electric noise voltage at the electrodes of the focused piezoelectric receiver is obtained.

Loading PDF

Similar Papers
  • Research Article
  • Citations40

The energy method for analyzing the piezoelectric electroacoustic transducers

  • Jan 01, 2005
  • The Journal of the Acoustical Society of America
  • Boris Aronov
  • Research Article

APPLICATION PIEZOELECTRIC TRANSDUCER IN ACOUSTIC MEASUREMENT SYSTEMS

  • Oct 01, 2025
  • Наукові праці Державного науково-дослідного інституту випробувань і сертифікації озброєння та військової техніки
  • V Zaika +3
  • Research Article
  • Citations33

Modeling and Simulation of Pulsed Electroacoustic Measurement Method

  • Dec 01, 2014
  • IEEE Systems Journal
  • Jaspreet Singh Chahal +1
  • Research Article

Numerical computation of acoustic radiation force in two and three dimensional resonators

  • Nov 01, 2013
  • The Journal of the Acoustical Society of America
  • Ari Mercado +4
  • Conference Article
  • Citations12

<title>Determination of piezoelectric transducer damping by using experimental and finite element simulations</title>

  • Jul 31, 2003
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Gilder Nader +2
  • Research Article
  • Citations15

Design and fabrication of an ultrasonic speaker with thickness mode piezoceramic transducers

  • Jan 29, 2002
  • Sensors and Actuators A: Physical
  • Yongrae Roh +1
  • Book Chapter
  • Citations1

Health Monitoring of Moving/Rotary Structures: An Electromechanical Impedance Approach Using Integrated Piezoceramic Transducers

  • Jul 22, 2021
  • Hamidreza Hoshyarmanesh +1
  • Research Article
  • Citations101

A stretchable and large-scale guided wave sensor network for aircraft smart skin of structural health monitoring

  • Jun 13, 2019
  • Structural Health Monitoring
  • Yu Wang +3
  • Conference Article
  • Citations6

Acoustic Radiation of Axially Stepped-Thickness Piezoelectric Cylindrical Shells

  • Nov 09, 2018
  • Ata Meshkinzar +1
  • Research Article
  • Citations9

Non-Foster acoustic radiation from an active piezoelectric transducer

  • Jul 19, 2021
  • Proceedings of the National Academy of Sciences
  • Curtis Rasmussen +1
  • Research Article
  • Citations4

Various Types of Defects Detection in Flat and Curved Laminated Composite Plates Using Nonintrusive Lamb Wave System

  • Jan 19, 2021
  • Journal of Nondestructive Evaluation, Diagnostics and Prognostics of Engineering Systems
  • Lingyu Yu +1
  • Research Article

High Performance of Electroacoustic Piezoelectric Ceramic Transducers

  • Apr 01, 1992
  • Acta Physica Polonica A
  • M.I Abd El-Ati +2
  • Research Article
  • Citations25

Compliance and control characteristics of an additive manufactured-flexure stage

  • Apr 01, 2015
  • Review of Scientific Instruments
  • Chabum Lee +1
  • Research Article

Electro-acoustic transducer and manufacturing process

  • Feb 01, 1992
  • The Journal of the Acoustical Society of America
  • Leonard D Amalaha
  • Conference Article
  • Citations5

<title>Parameter-based time domain design of wave-absorbing controllers for flexible structures using piezoelectric transducers</title>

  • May 01, 1996
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Aghil Yousefi-Koma +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.