Exploring the Performance of Alkaline Water Electrolyzers Under Dynamic Operational Conditions

Show More
  • Abstract
  • Literature Map
  • Citations
  • Similar Papers
Abstract

Green hydrogen, produced through water electrolysis driven by Renewable Energy Sources (RES), is a compelling solution for storing renewable energy. Directly coupling RES with water electrolyzers enhances system efficiency and cost-effectiveness. Alkaline water electrolysis, a mature and cost-effective technology, faces challenges operating under fluctuating RES conditions using AC/DC convertor , which supply rippled DC. A comprehensive understanding of electrolyzer performance in dynamic conditions is crucial for developing durable, efficient systems.In the present experimental study, we extensively explored the performance of alkaline water electrolyzers and the key factors influencing it under dynamic operational conditions. The electrolytic cell was constructed using a zero-gap configuration, comprising a NiCoOx-based anode deposited on a Ni-mesh and an Ln-doped RuOx cathode deposited on a fine mesh of Ni metal. The Zirfon Perl UTP500 membrane served as a separator between the two cell compartments [1]. A 7.0 Molar KOH electrolyte at a room temperature of approximately 30°C was employed. The cell underwent dynamic operational mode through the application of a square wave cell voltage, shown in Fig.1 (a), utilizing the NF BP4620 power supply. Square waves with different frequencies, specifically 1, 100, 1000, and 3000 Hz, were employed. Steady-state operations were conducted while applying various DC voltages, serving as a reference study. The resulting current and the actual cell voltage waveforms were monitored and recorded using a high-resolution oscilloscope (YOKOGAWA DL850E). The flow of H2 gas was measured using a film flow meter (HORIBA STEC, SF series VP-3). The apparent power, real power, and reactive power components were calculated using formulas from a previously published report [2]. Subsequently, the specific energy consumption was determined for each condition.The applied cell voltages were categorized into two groups. In the first category, the maximum cell voltage (Vmax) was set at 2.0 V, a value sufficiently high and suitable for industrial cell operation when applied in a DC mode. Within this category, the minimum cell voltage (Vmin) took various values, namely 1.8, 1.6, and 1.4 V. In the second category, the average cell voltage was maintained at a constant 2.0 V, while the amplitude of the waveform was adjusted to 0.2 and 0.4 V by modifying both Vmax and Vmin. Figure 1(b) depicts the resulting current of the voltage waveform at 100 Hz, illustrating three different Vmin values. The figure reveals that at a high Vmin of 1.8V, the current consistently maintained positive values during the voltage cycle, indicating that the double-layer capacitance remained charged throughout the operational period. However, with Vmin set at 1.6V, a relatively small capacitive current emerged, suggesting partial discharge of the double-layer capacitance. Moreover, at a lower Vmin of 1.4V, the cell voltage became insufficient to drive water electrolysis in the current cell. Consequently, a relatively large negative (capacitive) current manifested during the Vmin period, denoting a deep discharge of the double-layer capacitance.The obtained results revealed a profound influence of the charge and discharge status of the double-layer capacitance on the AWE cell's performance throughout the voltage cycles. Notably, when the double-layer capacitor remained fully charged during the voltage cycles, minimal impact of the frequency was observed on key performance parameters, including H2 flow rate that shown in figure 1 (c), specific energy consumption that shown in figure 1 (d), and power factor. However, under conditions of partial discharge within the cell voltage cycles, a noticeable correlation between the size and frequency of the voltage waveform and the AWE cell's performance emerged. Deep discharge of the double-layer capacitance led to a frequency-dependent reduction in H2 flow rate, attributed to incomplete charge/discharge cycles. Hence, the critical factor influencing the performance of the electrolytic cell during dynamic operation is the condition (charging/discharging) of the double-layer capacitance. These findings offer valuable insights into optimizing the dynamic operation of AWE cells for enhanced efficiency and performance. Acknowledgments: This research was partially supported by New Energy and Industrial Technology Development Organization (NEDO).

Similar Papers
  • Research Article
  • Citations150

Degradation study of a proton exchange membrane water electrolyzer under dynamic operation conditions

  • Oct 01, 2020
  • Applied Energy
  • Georgios Papakonstantinou +5
  • Research Article

Investigation of Both Electrolyte Supply Method and Membrane Thickness for Anion Exchange Membrane Water Electrolysis Cells Under High Current-Density Operation

  • Nov 24, 2025
  • Electrochemical Society Meeting Abstracts
  • Soichiro Natori +6
  • Research Article
  • Citations22

Operational parameters correlated with the long-term stability of anion exchange membrane water electrolyzers

  • Aug 04, 2021
  • International Journal of Hydrogen Energy
  • Atif Khan Niaz +2
  • Research Article
  • Citations1

(Digital Presentation) Water Oxidation in Acid with Earth-Abundant Electrocatalysts

  • Jul 07, 2022
  • ECS Meeting Abstracts
  • Shuang Kong +2
  • Research Article

Operando X-Ray Absorption Spectroscopy Study of RuCoOx Bifunctional Catalysts for Water Electrolysis

  • Nov 24, 2025
  • Electrochemical Society Meeting Abstracts
  • Zihao Zhang +7
  • Research Article
  • Citations62

Control technique for enhancing the stable operation of distributed generation units within a microgrid

  • Apr 05, 2015
  • Energy Conversion and Management
  • Majid Mehrasa +4
  • Research Article
  • Citations3

Effect of Ramping Rate on the Durability of Proton Exchange Membrane Water Electrolysis During Dynamic Operation Using Triangular Voltage Cycling

  • Feb 23, 2024
  • Journal of Electrochemical Science and Technology
  • Hye Young Jung +5
  • Research Article
  • Citations1

Wet Gas Water Feed of Polymer Electrolyte Membrane Electrolyzer for Simultaneous Hydrogenation of Organic Chemical Hydride Energy Carrier and Water Decomposition

  • Oct 09, 2022
  • ECS Meeting Abstracts
  • Shigenori Mitsushima +3
  • Research Article

Low-Ripple Modulation Strategy for a Photovoltaic-Based Triple-Port Hydrogen Production System

  • Jan 01, 2025
  • IEEE Transactions on Industrial Electronics
  • Shiqi Zhang +6
  • Research Article

(Invited) Reverse Current Behavior and ADT Protocol for Start & Stop Operation of Bipolar Alkaline Water Electrolyzer

  • May 01, 2020
  • Electrochemical Society Meeting Abstracts
  • Shigenori Mitsushima +6
  • Research Article

Power Quality Enhancement in Hybrid AC/DC Microgrid using ANN

  • Jan 31, 2026
  • International Journal for Research in Applied Science and Engineering Technology
  • Gundamalla Geethanjali +1
  • Research Article

Evaluation of Leak and Reverse Current in a Bipolar Electrolyzer

  • Sep 01, 2016
  • Electrochemical Society Meeting Abstracts
  • Takayuki Kobayashi +7
  • Conference Article
  • Citations5

Control strategy for the stable operation of multilevel converter topologies in DG technology

  • Aug 01, 2014
  • Edris Pouresmaeil +2
  • Research Article

Prediction of PEMFC life based on IGJO-TCN-BiGRU-Attention

  • Dec 01, 2025
  • Scientific Reports
  • Jun Zhao +5
  • Research Article

Piezoelectric Composite Actuators: Modelling of the Static and Dynamic Behaviour

  • Oct 10, 2013
  • Research Repository (Delft University of Technology)
  • Peerawan Wiwattananon
Cactus Communications logo