• Home
  • Search
  • Fast and Accurate Automatic Registration for MR-Guided Procedures Using Active Microcoils
  • Cite Icon17
  • https://doi.org/10.1109/tmi.2006.889748Copy DOI Icon

Fast and Accurate Automatic Registration for MR-Guided Procedures Using Active Microcoils

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

A fast, robust, accurate, and automatic registration technique based on magnetic resonance (MR) active microcoils (active markers) for registration of tracked medical devices to preprocedural MR-images is presented. This allows for a straight-forward integration of position measurement systems into clinical procedures. The presented method is useful for guidance purposes in clinical applications with high demands on accuracy and ease-of-use (e.g., neurosurgical or orthopedic applications). The determination of the positions of the active markers is integrated into the preparation phase of the actual MR imaging scan. The technique features a generic interface using DICOM standards for communication with navigation workstations linked to an MR system. The position of the active markers is fixed with respect to a reference system of an optical positioning measurement system (OPMS) and thus the coregistration of the MR system and the OPMS is established. In a phantom study, a mean overall targeting accuracy of 0.9+/-0.1 mm was achieved and compared favorably to results obtained from manual registration tests (1.8+/-0.3 mm) carried out in parallel. For a test person trained for both registration methods, workflow improvements of 3-6 min per registration step were found. The need for manual interaction is entirely eliminated thus avoiding user-bias, which is advantageous for the usage in clinical routine. The method improves the ease-of-use of tracking equipment during stereotactic guidance. The method is finally demonstrated in a volunteer study using a model of a Mayfield skull clamp with integrated active and optical reference markers.

Similar Papers
  • Research Article
  • Citations16

Automatic Registration between Real-Time Ultrasonography and Pre-Procedural Magnetic Resonance Images: A Prospective Comparison between Two Registration Methods by Liver Surface and Vessel and by Liver Surface Only

  • Apr 13, 2016
  • Ultrasound in Medicine & Biology
  • Ah Yeong Kim +15
  • Book Chapter
  • Citations2

Challenges of Using 3 T MR Systems and Whole-Body MRI for Lung Imaging

  • Jan 01, 2016
  • Yoshiharu Ohno +3
  • Research Article
  • Citations126

Revised guidance on acceptable limits of exposure during nuclear magnetic resonance clinical imaging.

  • Dec 01, 1983
  • The British journal of radiology
  • Research Article
  • Citations4

Automatic 3D Registration of CT-MR Head and Neck Images With Surface Matching

  • Jan 01, 2019
  • IEEE Access
  • Qin Chu +4
  • Research Article
  • Citations56

Abdominal Applications of 3.0-T MR Imaging: Comparative Review versus a 1.5-T System

  • Apr 21, 2008
  • RadioGraphics
  • Jin-Young Choi +6
  • Research Article
  • Citations29

Cardiac gated breath-hold black blood MRI of the coronary artery wall: an in vivo and ex vivo comparison.

  • Jan 01, 2001
  • The international journal of cardiovascular imaging
  • Stephen G Worthley +6
  • Research Article
  • Citations40

Evaluation of Patients with Paramyotonia at23Na MR Imaging during Cold-induced Weakness

  • Jun 14, 2006
  • Radiology
  • Marc-André Weber +9
  • Research Article
  • Citations38

Generation and observation of radio frequency thermal lesion ablation for interventional magnetic resonance imaging.

  • Aug 01, 1997
  • Investigative radiology
  • Yiu-Cho Chung +2
  • Research Article
  • Citations26

A method for quantitative analysis of regional lung ventilation using deformable image registration of CT and hybrid hyperpolarized gas/1H MRI

  • Nov 10, 2014
  • Physics in Medicine & Biology
  • Bilal A Tahir +10
  • Book Chapter

Assessment of reproducibility of Geometric Distortion in MRI based on phantom measurements

  • Jan 01, 2007
  • M Ashkanmehr +6
  • Research Article
  • Citations107

Multimodality image registration quality assurance for conformal three-dimensional treatment planning

  • Aug 15, 2001
  • International Journal of Radiation Oncology*Biology*Physics
  • Sasa Mutic +8
  • Research Article
  • Citations21

A complete software application for automatic registration of x-ray mammography and magnetic resonance images.

  • Jul 10, 2014
  • Medical Physics
  • J A Solves‐Llorens +5
  • Research Article
  • Citations1

Evaluation of the geometric and dosimetric accuracies of deformable image registration of targets and critical organs in prostate CBCT‐guided adaptive radiotherapy

  • Sep 13, 2024
  • Journal of Applied Clinical Medical Physics
  • Hussam Hameed Jassim +5
  • Research Article
  • Citations163

3-Dimensional Elastic Registration System of Prostate Biopsy Location by Real-Time 3-Dimensional Transrectal Ultrasound Guidance With Magnetic Resonance/Transrectal Ultrasound Image Fusion

  • Jan 21, 2012
  • Journal of Urology
  • Osamu Ukimura +7
  • Research Article
  • Citations19

A review of MRI studies in Africa with special focus on quantitative MRI: Historical development, current status and the role of medical physicists

  • Oct 08, 2022
  • Physica Medica
  • Francis Hasford +35
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.