Abstract

The ultra-high voltage electron microscope (UHVEM) H-3000 with the world highest acceleration voltage of 3 MV can observe remarkable three dimensional microstructures of microns-thick samples[1]. Acquiring a tilt series of electron tomography is laborious work and thus an automatic technique is highly desired. We proposed the Auto-Focus system using image Sharpness (AFS)[2,3] for UHVEM tomography tilt series acquisition. In the method, five images with different defocus values are firstly acquired and the image sharpness are calculated. The sharpness are then fitted to a quasi-Gaussian function to decide the best focus value[3]. Defocused images acquired by the slow scan CCD (SS-CCD) camera (Hitachi F486BK) are of high quality but one minute is taken for acquisition of five defocused images.In this study, we introduce a high-definition video camera (HD video camera; Hamamatsu Photonics K. K. C9721S) for fast acquisition of images[4]. It is an analog camera but the camera image is captured by a PC and the effective image resolution is 1280×1023 pixels. This resolution is lower than that of the SS-CCD camera of 4096×4096 pixels. However, the HD video camera captures one image for only 1/30 second. In exchange for the faster acquisition the S/N of images are low. To improve the S/N, 22 captured frames are integrated so that each image sharpness is enough to become lower fitting error. As countermeasure against low resolution, we selected a large defocus step, which is typically five times of the manual defocus step, to discriminate different defocused images.By using HD video camera for autofocus process, the time consumption for each autofocus procedure was reduced to about six seconds. It took one second for correction of an image position and the total correction time was seven seconds, which was shorter by one order than that using SS-CCD camera. When we used SS-CCD camera for final image capture, it took 30 seconds to record one tilt image. We can obtain a tilt series of 61 images within 30 minutes. Accuracy and repeatability were good enough to practical use (Figure1). We successfully reduced the total acquisition time of a tomography tilt series in half than before.jmicro;63/suppl_1/i25/DFU066F1F1DFU066F1Fig. 1.Objective lens current change with a tilt angle during acquisition of tomography series (Sample: a rat hepatocyte, thickness: 2 m, magnification: 4k, acc. voltage: 2 MV). Tilt angle range is ±60 degree with 2 degree step angle. Two series were acquired in the same area. Both data were almost same and the deviation was smaller than the minimum step by manual, so auto-focus worked well. We also developed a computer-aided three dimensional (3D) visualization and analysis software for electron tomography "HawkC" which can sectionalize the 3D data semi-automatically[5,6]. If this auto-acquisition system is used with IMOD reconstruction software[7] and HawkC software, we will be able to do on-line UHVEM tomography. The system would help pathology examination in the future.This work was supported by the Ministry of Education, Culture, Sports, Science and Technology (MEXT), Japan, under a Grant-in-Aid for Scientific Research (Grant No. 23560024, 23560786), and SENTAN, Japan Science and Technology Agency, Japan.

Similar Papers
  • Research Article
  • Citations1

Automatic system for electron tomography data collection in the ultra-high voltage electron microscope

  • Sep 12, 2017
  • Micron
  • Meng Cao +2
  • Research Article
  • Citations8

Evaluation of scanners and CCD cameras for high-resolution TEM of protein crystals and single particles.

  • Apr 27, 2000
  • Microscopy research and technique
  • Joergen Hesse +2
  • Research Article
  • Citations96

Electron detection characteristics of a slow-scan CCD camera, imaging plates and film, and electron image restoration.

  • Apr 27, 2000
  • Microscopy Research and Technique
  • J M Zuo
  • PDF
  • Research Article
  • Citations12

Ultra-high voltage electron microscopy of primitive algae illuminates 3D ultrastructures of the first photosynthetic eukaryote.

  • Oct 06, 2015
  • Scientific Reports
  • Toshiyuki Takahashi +4
  • Book Chapter
  • Citations1

Electron tomography: influence of defocus on the determination of reconstructed soot aggregates' surface and volume

  • Dec 20, 2016
  • Martiane Cabié +2
  • Research Article
  • Citations9

EPiK-a Workflow for Electron Tomography in Kepler

  • Jan 01, 2014
  • Procedia Computer Science
  • Ruijuan Chen +7
  • Research Article
  • Citations1

Time‐Efficient Electron Tomography for a Quantitative Description of Chiral Nanorods

  • Nov 08, 2025
  • Advanced Optical Materials
  • Valentina Girelli Consolaro +7
  • Research Article

Automation of Tilt Series Acquisition in Transmission Electron Microscopy for Applications in Biology and Materials Science

  • Aug 01, 2001
  • Microscopy and Microanalysis
  • Ingo Daberkow +3
  • Book Chapter
  • Citations11

Procedures for Three-Dimensional Reconstruction from Thin Sections with Electron Tomography

  • Jan 01, 1998
  • Ulf Skoglund +2
  • Research Article
  • Citations12

Image quality of microns-thick specimens in the ultra-high voltage electron microscope

  • Feb 11, 2010
  • Micron
  • Fang Wang +4
  • Book Chapter

Quantitative Electron Tomography Study of Metal Catalysts Supported on Heavy Oxides Combining Image De‐noising and Compressed Sensing Techniques

  • Dec 20, 2016
  • Miguel Lopez‐Haro +3
  • Research Article

Strategy for Dissemination of Practical Tools for Evaluation of Vulnerability and Safety of Houses in the Philippines

  • Feb 01, 2015
  • Journal of Disaster Research
  • Joan L Cruz-Salcedo +8
  • Research Article
  • Citations3

A novel constrained reconstruction model towards high-resolution subtomogram averaging.

  • Oct 16, 2019
  • Bioinformatics
  • Renmin Han +4
  • Book Chapter
  • Citations18

D2HNet: Joint Denoising and Deblurring with Hierarchical Network for Robust Night Image Restoration

  • Jan 01, 2022
  • Yuzhi Zhao +5
  • Research Article

Crista Junctions of Mitochondria Visualized by Electron Tomography

  • Jul 01, 1998
  • Microscopy and Microanalysis
  • G A Perkins +6
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.