  • Fault Detection based on MCSA for a 400Hz Asynchronous Motor for Airborne Applications
  • Cite Icon6
  • https://doi.org/10.36001/ijphm.2013.v4i2.2123Copy DOI Icon

Fault Detection based on MCSA for a 400Hz Asynchronous Motor for Airborne Applications

Show More
  • Abstract
  • Highlights & Summary
  • PDF
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Future health monitoring concepts in different fields of engineering require reliable fault detection to avoid unscheduled machine downtime. Diagnosis of electrical induction machines for industrial applications is widely discussed in literature. In aviation industry, this topic is still only rarely discussed. A common approach to health monitoring for electrical induction machines is to use Motor Current Signature Analysis (MCSA) based on a Fast Fourier Transform (FFT). Research results on this topic are available for comparatively large motors, where the power supply is typically based on 50Hz alternating current, which is the general power supply frequency for industrial applications. In this paper, transferability to airborne applications, where the power supply is 400Hz, is assessed. Three phase asynchronous motors are used to analyse detectability of different motor faults. The possibility to transfer fault detection results from 50Hz to 400Hz induction machines is the main question answered in this research work. 400Hz power supply frequency requires adjusted motor design, causing increased motor speed compared to 50Hz supply frequency. The motor used for experiments in this work is a 800W motor with 200V phase to phase power supply, powering an avionic fan. The fault cases to be examined are a bearing fault, a rotor unbalance, a stator winding fault, a broken rotor bar and a static air gap eccentricity. These are the most common faults in electrical induction machines which can cause machine downtime. The focus of the research work is the feasibility of the application of MCSA for small scale, high speed motor design, using the Fourier spectra of the current signal. Detectability is given for all but the bearing fault, although rotor unbalance can only be detected in case of severe damage level. Results obtained in the experiments are interpreted withrespect to the motor design. Physical interpretation are given in case the results differ from those found in literature for 50Hz electrical machines.

Loading PDF

Similar Papers
  • PDF
  • Book Chapter
  • Citations13

Wavelet-Based Analysis of MCSA for Fault Detection in Electrical Machine

  • Dec 09, 2015
  • Mohammad Rezazadeh Mehrjou +8
  • Research Article

Induction Motor Multiple Fault Analysis using Stray Flux Signals: A Review

  • Jul 20, 2025
  • Transactions on Maritime Science
  • Luka Čulić +3
  • Conference Article
  • Citations6

A detailed study of the spectral content in the stator current of asynchronous machines under broken rotor bar faults using MCSA technique

  • Oct 01, 2018
  • Noureddine Bessous +2
  • Research Article
  • Citations181

Fault detection and diagnosis of induction motors using motor current signature analysis and a hybrid FMM-CART model.

  • Jan 01, 2012
  • IEEE Transactions on Neural Networks and Learning Systems
  • M Seera +3
  • Research Article
  • Citations48

Offline and online fault detection and diagnosis of induction motors using a hybrid soft computing model

  • Sep 14, 2013
  • Applied Soft Computing
  • Manjeevan Seera +3
  • Research Article
  • Citations6

Revolutionizing motor maintenance: a comprehensive survey of state-of-the-art fault detection in three-phase induction motors

  • Sep 01, 2024
  • International Journal of Power Electronics and Drive Systems (IJPEDS)
  • Bahgat Hafez Bahgat +3
  • Book Chapter

Application of Teager Energy for Broken Rotor bar Fault Detection Based on the Motor Current Signature Analysis

  • Jan 01, 2021
  • Haiyang Li +5
  • Conference Article
  • Citations7

Fault diagnosis of an induction motor through motor current signature analysis, FFT & DWT analysis

  • Nov 01, 2017
  • A C Abhinandan +1
  • Conference Article
  • Citations10

Experimental evaluation of motor current signature and vibration analysis for rotor broken bars detection in an induction motor

  • May 01, 2011
  • S J Oviedo +2
  • Research Article
  • Citations31

Fault Detection and Identification Using Deep Learning Algorithms in Induction Motors

  • Jan 01, 2022
  • Computer Modeling in Engineering & Sciences
  • Majid Hussain +4
  • Research Article
  • Citations1

Rotor Fault Detection in Squirrel Cage Induction Motors using MCSA and DWT Techniques

  • Mar 31, 2021
  • Algerian Journal of Signals and Systems
  • Noureddine Bessous +3
  • Research Article
  • Citations63

A Multiresolution Taylor–Kalman Approach for Broken Rotor Bar Detection in Cage Induction Motors

  • Jun 01, 2018
  • IEEE Transactions on Instrumentation and Measurement
  • Luis Alonso Trujillo-Guajardo +3
  • Book Chapter
  • Citations4

Gear fault diagnosis by motor current analysis: application to industrial cases

  • Jan 01, 2014
  • International Gear Conference 2014
  • F Combet
  • Research Article
  • Citations14

Advanced Fault Detection and Severity Analysis of Broken Rotor Bars in Induction Motors: Comparative Classification and Feature Study Using Dimensionality Reduction Techniques

  • Dec 06, 2024
  • Machines
  • Rahul R Kumar +5
  • Conference Article
  • Citations62

Broken rotor bar fault detection in induction motors using Wavelet Transform

  • Mar 01, 2012
  • Khadim Moin Siddiqui +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.