• Home
  • Search
  • Feasibility study of highly accelerated phase-sensitive inversion recovery myocardial viability imaging using simultaneous multislice and parallel imaging techniques.
  • Cite Icon2
  • https://doi.org/10.1002/jmri.26795Copy DOI Icon

Feasibility study of highly accelerated phase-sensitive inversion recovery myocardial viability imaging using simultaneous multislice and parallel imaging techniques.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Phase-sensitive inversion recovery (PSIR) is a powerful cardiac MRI method to assess myocardial viability, which can eliminate the background phase and preserve the sign of the desired magnetization during inversion recovery. To shorten the acquisition time of myocardial viability imaging by introducing both simultaneous multislice (SMS) and parallel imaging (PI) into PSIR without additional acquisitions for calibration data. Prospective study. A high-resolution phantom and three vials with doped solutions matching typical postcontrast T1 and T2 values of scar, healthy myocardium, and blood; 18 patients (six with known myocardial infarction) were included in this study. 3T/segmented fast spoiled gradient echo pulse sequence. Phantom and in vivo experiments were performed to compare the performance of conventional PSIR, SMS accelerated PSIR (SMS-PSIR, 2× acceleration), and SMS as well as PI accelerated PSIR (SMS + PI-PSIR, 4× acceleration). In phantom experiments, the error maps, local signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated. In in vivo experiments, the image quality and artifact level of each study were qualitatively graded (by three radiologists). G-factor maps were calculated. The infarct size presented as a percentage of the left ventricle was measured (full-width half-maximum). Acquisition time of each study was recorded. One-way analysis of variance, Kruskal-Wallis test. In phantom experiments, SNR and CNR were well preserved for SMS-PSIR, while they dropped for SMS + PI-PSIR, as expected. In 15 subjects, the overall image quality scores were not significantly different among conventional PSIR (3.70 ± 1.06), SMS-PSIR (3.78 ± 0.99), and SMS + PI-PSIR (3.47 ± 0.94; P = 0.20). The artifact level scores were also comparable among conventional PSIR (3.67 ± 1.04), SMS-PSIR (3.77 ± 1.03), and SMS + PI-PSIR (3.45 ± 1.00; P = 0.22). SMS-PSIR achieved negligible g-factor noise amplification (1.04 ± 0.03) and SMS + PI-PSIR showed higher g-factors (2.83 ± 0.48). The infarct size was consistent among conventional PSIR (22.51 ± 25.05%) and SMS-PSIR (22.98 ± 26.19%), as well as SMS + PI-PSIR (22.93 ± 25.68%; P = 0.98). The acquisition time of two short-axis slices for SMS-PSIR (17.6 ± 1.7 sec, 16 heartbeats) and SMS + PI-PSIR (9.8 ± 1.9 sec, 8 heartbeats) was 30% and 17% of that for conventional PSIR (56.2 ± 8.5 sec, 32 heartbeats), respectively. SMS can be implemented in PSIR without additional reference scan. The image quality is comparable with conventional PSIR, while the acquisition time is much shorter. The proposed method is also compatible with PI to further reduce the scan time. 2 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2019;50:1964-1972.

Similar Papers
  • Research Article
  • Citations9

Clinical feasibility of simultaneous multi-slice imaging with blipped-CAIPI for diffusion-weighted imaging and diffusion-tensor imaging of the brain

  • Mar 31, 2017
  • Acta Radiologica
  • Hajime Yokota +6
  • Research Article
  • Citations2

An end-to-end deep learning method for reconstructing SMS-PI accelerated musculoskeletal MRI.

  • Dec 01, 2025
  • Medical physics
  • Mahmoud Mostapha +8
  • Research Article
  • Citations5

Myocardial motion-corrected phase-sensitive inversion recovery late gadolinium enhancement in free breathing paediatric patients: a comparison with single-shot coherent gradient echo (“TrueFISP”) phase-sensitive inversion recovery

  • Mar 02, 2021
  • Clinical Radiology
  • L.J Xie +9
  • Research Article
  • Citations1

Fast reconstruction of SMS bSSFP myocardial perfusion images using noise map estimation network (NoiseMapNet): a head-to-head comparison with parallel imaging and iterative reconstruction.

  • Jul 11, 2024
  • Frontiers in cardiovascular medicine
  • Naledi Lenah Adam +13
  • Research Article
  • Citations3

Optimizing diffusion MRI acquisition efficiency of rodent brain using simultaneous multislice EPI.

  • Aug 24, 2020
  • NMR in Biomedicine
  • Hsu-Lei Lee +3
  • Research Article
  • Citations15

Coil compression in simultaneous multislice functional MRI with concentric ring slice-GRAPPA and SENSE.

  • Oct 28, 2015
  • Magnetic resonance in medicine
  • Alan Chu +1
  • Conference Article

8-fold Accelerated TSE MRI: First Clinical Results of an End-to-End DL Reconstruction Method for Combined SMS and Parallel Imaging Acceleration

  • Sep 16, 2025
  • Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
  • Yannik Leonhardt +7
  • Research Article

Diffusion-weighted imaging of the head and neck: comparison between integrated slice-specific dynamic shimming and simultaneous multi-slice readout-segmented echo-planar sequences.

  • Dec 05, 2024
  • Dento maxillo facial radiology
  • Tong Su +11
  • Research Article

Efficient Interleaved Multi-Band Outer Volume Suppression for Highly Accelerated Simultaneous Multi-Slice Imaging of the Heart.

  • Feb 28, 2026
  • Bioengineering (Basel, Switzerland)
  • Ayda Arami +9
  • Research Article
  • Citations8

Effectiveness of simultaneous multislice accelerated readout-segmented echo planar imaging for the assessment of rectal cancer

  • Dec 13, 2022
  • European Journal of Radiology
  • Lanqing Yang +8
  • Research Article

An Examination for Uterine Dynamic Study with Phase-sensitive Inversion-recovery

  • Jan 01, 2016
  • Nihon Hoshasen Gijutsu Gakkai zasshi
  • Yasuo Takatsu +3
  • PDF
  • Research Article
  • Citations5

Feasibility of Simultaneous Multislice Acceleration Technique in Readout-Segmented Echo-Planar Diffusion-Weighted Imaging for Assessing Rectal Cancer.

  • Jan 28, 2023
  • Diagnostics
  • Mi Zhou +3
  • PDF
  • Research Article
  • Citations1

Simultaneous Multislice Brain MRI T1 Mapping with Improved Low-Rank Modeling

  • Oct 07, 2021
  • Tomography
  • Sugil Kim +1
  • Book Chapter
  • Citations16

Motion-Robust Reconstruction Based on Simultaneous Multi-slice Registration for Diffusion-Weighted MRI of Moving Subjects

  • Jan 01, 2016
  • Bahram Marami +4
  • Research Article
  • Citations198

High-resolution in vivo diffusion imaging of the human brain with generalized slice dithered enhanced resolution: Simultaneous multislice (gSlider-SMS).

  • Mar 05, 2017
  • Magnetic Resonance in Medicine
  • Kawin Setsompop +10
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.