• Home
  • Search
  • Feedback Control Is Engineering, Let's Treat It as Such
  • Cite Icon7
  • https://doi.org/10.1097/aln.0b013e3182625526Copy DOI Icon

Feedback Control Is Engineering, Let's Treat It as Such

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Florida Hospital, Orlando, Florida, and JLR Medical Group, Maitland, Florida. tdlooke@hotmail.comTo the Editor: As a practicing anesthesiologist with a Ph.D. in control systems engineering, I feel compelled to comment on both the merits and hazards of closed-loop control (CLC) in the operating room, as discussed in the February 2012 article by Liu et al. 1and the accompanying editorial.2CLC is a mature field of engineering with well established standards of analysis, design, and reporting – points missing from Liu et al. 's article and the accompanying editorial. This absence suggests unfamiliarity with the hazards of CLC, which include the risk of introducing instability where none existed before.My main criticism of Liu et al. 's work is that there is no evidence that the appropriate groundwork was done to ensure that the control algorithm was safe (stable) before entering the operating room. Minimizing the hazards of CLC requires a thorough stability analysis before implementation. By way of comparison, it is as important to precede CLC operational testing with computer modeling and simulation studies as it is to precede human drug trials with animal modeling and testing. Testing under extremes of “physiologically challenging conditions such as hypertension, hypotension, morbid obesity, in pediatric patients, or during major surgery such as cardiac surgery or lung transplantation,” as the authors propose for their next clinical trial (see Discussion1), should have been done by simulation before the first clinical trial.Controller design is the key to ultimate success and acceptance of any closed-loop strategy. There are dozens of ways to design closed-loop algorithms. Of all of the available approaches, it is noteworthy that the authors decided to use the PID, or proportional, integral, derivative, approach. The details of how PID controllers work are not important for this point of discussion. The important issue is that the PID approach is the most basic and unsophisticated of algorithms–the first one learned by every CLC engineer in their first undergraduate control course–and is suitable for some simple mechanical, electrical, or hydraulic systems (e.g. , automobile cruise control), but not for complicated, time-variant, nonlinear systems with time delays (e.g. , the surgical patient).Lastly, Liu et al. 's article lacks the necessary engineering detail to evaluate the work. By piecing together comments from the present paper and previous work,3,4it is possible, however, to determine that the controller is in fact not a PID controller. Instead, the authors used empirical methods to develop look-up tables and logic trees to mimic the proportional (P) and derivative (D) terms of a classic PID while ignoring the integral (I) term altogether. The result is that the control algorithm looks more like a crude expert system than a PID controller. An expert system of this type is what would result from a survey of anesthesiologists asked what they would do with propofol and remifentanil infusion rates given particular entropy values.In conclusion, what the authors have done is replace the human anesthesiologist with an ideal, empirically derived, computer anesthesiologist dedicated to the one task of maintaining a set entropy value. For this menial task, the computer wins. For the advancement of closed-loop control design in the operating room, no one wins.Studies using CLC have the potential to significantly impact our specialty and, more importantly, our patients. When considering the publication of CLC articles, the editors of ANESTHESIOLOGY must consider using a control systems engineer in the peer review process. There is precedent for recent and good systems engineering work in the anesthesia literature. I refer to the work of De Smet et al. ,5,6where the authors follow a sound engineering development strategy.Finally, perhaps Crosby and Culley think the future bright if “a dozen operating rooms filled with patients having surgery” are managed by a “lone anesthesiologist … from a distant location.”2In my view, this is an unholy grail. Almost every paper about “closed-loop” anesthesia discusses the similarities of our environment and the cockpit. Without doubt there is one way they are exactly alike: Patients and passengers would recoil if they were to learn that their anesthesiologist or pilot would be in abstentia. The ideal goal of control systems engineering in the operating room is not the elimination of anesthesia staff, but the ability to prescribe an effect rather than a dose. Imagine a future where we say “set end-tidal carbon dioxide to 36, set mean arterial pressure to 80, set heart rate to 70, set pain response to 0, set awareness to 45,” and then watch as safe, stable, robust, and reliable control algorithms adjust all fluids and anesthetics at once to achieve these results. This is a bright future, indeed.

Similar Papers
  • Research Article
  • Citations27

A method of multichannel PID control of two‐degree‐of‐freedom wrist joint movements by functional electrical stimulation

  • Mar 18, 2003
  • Systems and Computers in Japan
  • Takashi Watanabe +3
  • Conference Article
  • Citations25

A Control and Drive System for Pneumatic Soft Robots: PneuSoRD

  • Sep 27, 2021
  • Taylor R Young +3
  • Research Article

A Study of Turbine Engine PID Control Method Based on Closed-Loop Gain Shaping Algorithm

  • Feb 01, 2012
  • Advanced Materials Research
  • Jie Tang Zhu +4
  • Research Article
  • Citations66

Outpatient Closed-Loop Control with Unannounced Moderate Exercise in Adolescents Using Zone Model Predictive Control.

  • May 01, 2017
  • Diabetes Technology & Therapeutics
  • Lauren M Huyett +11
  • Research Article
  • Citations2

Recurrent-neural-network-based identification of a cascade hydraulic actuator for closed-loop automotive power transmission control

  • May 01, 2012
  • Journal of Mechanical Science and Technology
  • Seung-Han You +1
  • Research Article
  • Citations3

High-stability electrohydrodynamic inkjet printing based on double closed-loop fuzzy control.

  • Jul 16, 2025
  • Scientific reports
  • Yifang Liu +7
  • Conference Article
  • Citations7

Fuzzy PID Controller for FOPDT System Based on a Hardware-in-the-Loop Simulation

  • Jul 01, 2018
  • Yang Zhou +3
  • Research Article

Fuzzy Adaptive PID Control of a Shell and Tube Heat Exchanger Output Temperature

  • Nov 30, 2020
  • International Review of Automatic Control (IREACO)
  • Gaudy Prada +2
  • Conference Article
  • Citations1

Study of closed-loop control of two-stage matrix converter based on expert control

  • Jul 01, 2008
  • Tianxiang Wen +2
  • Research Article
  • Citations5

A Robust and Adaptive Control Algorithm for Closed-Loop Brain Stimulation.

  • Nov 01, 2021
  • Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
  • Hao Fang +1
  • Conference Article
  • Citations21

Application of Velocity Profile Generation and Closed-Loop Control in Step Motor Control System

  • Jan 01, 2006
  • Ngoc Le +2
  • PDF
  • Research Article
  • Citations1

Experimental Study on Constant Speed Control Technology of Hydraulic Drive Pavers

  • Feb 04, 2023
  • Processes
  • Xiujie Yin +3
  • Conference Article
  • Citations4

Control strategy of three-phase PWM rectifier based on improved double closed loop sliding mode control

  • Feb 24, 2023
  • Xingzhi Zhang +3
  • Research Article
  • Citations12

Influence of riser-induced slugs on the downstream separation processes

  • May 03, 2017
  • Journal of Petroleum Science and Engineering
  • Simon Pedersen +2
  • Conference Article
  • Citations7

Research and comparison of automatic control algorithm for unmanned ship

  • Apr 01, 2018
  • Bao Yao +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.