• Home
  • Search
  • Frequency response analysis for transformer tap changer damage detection
  • Cite Icon11
  • https://doi.org/10.11591/ijpeds.v11.i1.pp350-358Copy DOI Icon

Frequency response analysis for transformer tap changer damage detection

  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Frequency response analysis (FRA) method has been proven to detect the transformer winding damage. However, there is no practical study which investigates the damages on transformer tap changer even though it has a high failure rate. Hence, this paper investigates normal and faulty transformer tap changer using FRA. The FRA measurements conducted using four different test configurations. Also, normal tap changer, pitting and coking tap changer contact were investigated. In addition to FRA measurement, winding resistance measurement has been conducted. The transformer turn ratio measurement also conducted to identify the taps positions. This study results significant to understand the effect of pitting and coking tap changer on the transformer frequency response. The results showed that pitting has a slight influence on the frequency response. However, coking shows a huge variation in low-frequency response. This effect observed during the winding resistance measurement.

Similar Papers
  • Research Article
  • Citations8

Nonconventional measurements on insulation materials high voltage bushings and power cables using frequency response analysis method

  • Feb 27, 2020
  • Engineering Reports
  • Saravanakumar Arumugam
  • Conference Article
  • Citations7

A study on frequency response analysis using friction model for frictional systems

  • Feb 01, 2017
  • Yuki Sugiura +3
  • Conference Article
  • Citations5

Shunt capacitance influences on single-phase transformer FRA spectrum

  • Jun 01, 2013
  • Mehdi Bagheri +3
  • PDF
  • Research Article
  • Citations11

The Influence of Capacitance and Inductance Changes on Frequency Response of Transformer Windings

  • Mar 12, 2019
  • Applied Sciences
  • Szymon Banaszak +3
  • Conference Article
  • Citations50

Investigations on sensitivity of FRA technique in diagnosis of transformer winding deformations

  • Sep 19, 2004
  • J.A.S.B Jayasinghe +3
  • Research Article
  • Citations7

A multimode perturbation method for frequency response analysis of nonlinearly vibrational beams with periodic parameters

  • Dec 18, 2019
  • Journal of Vibration and Control
  • Zu-Guang Ying +1
  • Conference Article
  • Citations3

Coordinated AVQC operations of EHV transformer's tap changer by fuzzy expert control system

  • Dec 10, 2002
  • M Suzuki +3
  • Research Article
  • Citations2

Frequency Response Analysis‐Based Transformer Condition Monitoring Supported by Artificial Intelligence—A Review

  • Jan 01, 2025
  • IET Science, Measurement & Technology
  • Jawad Faiz +3
  • Conference Article
  • Citations3

Short-circuit Fault Detection in Power Transformer Using Frequency Response Analysis bipolar signature of Inductive Inter-Winding Measurement

  • Mar 06, 2023
  • Ahmed Allawy Alawady +4
  • Conference Article
  • Citations6

Inductive coupling method for on-line frequency response analysis (FRA) for transformer winding diagnostic

  • Nov 01, 2017
  • Sooriya Bandara Rathnayaka +5
  • Research Article
  • Citations15

Topology optimization for fiber-reinforced plastic (FRP) composite for frequency responses

  • Jun 08, 2024
  • Computer Methods in Applied Mechanics and Engineering
  • Furong Xie +6
  • Conference Article
  • Citations3

PCA-Assisted Location of Small Short Circuit in Transformer Winding

  • Aug 04, 2020
  • Arash Moradzadeh +1
  • Conference Article
  • Citations2

Windings of a Power Transformer, Its Frequency Response and FEM Analysis

  • Mar 05, 2021
  • Sibabrata Pradhan +1
  • Research Article
  • Citations11

FRA lookup charts for the quantitative determination of winding axial displacement fault in power transformers

  • Sep 08, 2020
  • IET Electric Power Applications
  • Mehran Tahir +1
  • Conference Article

Short Circuit Fault at Delta Connection Induction Motor Using FRA Method: Experimental Analysis

  • Dec 07, 2025
  • Salem Mgammal Al-Ameri +4
Cactus Communications logo