Abstract

In recent years, the X-ray interferometer using dual phase gratings has been extensively studied. The large periodic fringes produced by the X-ray interferometer using dual phase gratings can be directly detected by ordinary detectors. At the same time, the X-ray interferometer using dual phase gratings can reduce the radiation dose of the sample without using absorption gratings. Meanwhile, a high fringe visibility is always preferred to achieve a high signal-to-noise ratio for X-ray grating interferometry. However, recent studies have reported that experimental fringe visibility in X-ray interferometer using dual rectangular phase gratings is relatively low. Therefore, it is necessary to further increase the fringe visibility in X-ray interferometry using dual phase gratings. This work focuses on the analysis of fringe visibility in X-ray interferometer using dual triangular phase gratings. Based on the fringe intensity distribution formula of X-ray dual phase grating interferometer, the fringe visibility of the dual triangular phase grating interferometer is investigated as a function of the grating spacing under monochromatic and polychromatic illumination, respectively. For comparison, the fringe visibility of the dual rectangular phase grating interferometer is also studied under the same condition. The results show that the maximum fringe visibility of the dual triangular phase grating interferometer increases with the phase shift increasing regardless of monochromatic or polychromatic illumination. Under monochromatic illumination, the maximum fringe visibility of dual 5π/2 triangular phase gratings is about 21% higher than that of dual rectangular phase gratings. Under polychromatic illumination, the fringe visibility of dual 5π/2 triangular phase gratings is at least 23% higher than that of dual rectangular phase gratings. Under polychromatic illumination, the greater the deviation of X-ray average energy from the grating design energy, the greater the decrease of maximum fringe visibility of the dual phase grating interferometer is. In addition, with the increase of the focal size of X-ray source, the maximum fringe visibility of the dual phase grating interferometer decreases, under polychromatic illumination. We hope that those results can be used as guidelines for designing and optimizing X-ray interferometer using dual triangular phase gratings.

Similar Papers
  • Research Article
  • Citations3

Interaction of polarized beam with copper surface and its application for metal-dielectric discrimination of vero board

  • Mar 01, 2009
  • Journal of Optics
  • S Chakraborty +1
  • Research Article
  • Citations24

High energy x-ray phase contrast CT using glancing-angle grating interferometers.

  • Jan 16, 2014
  • Medical Physics
  • A Sarapata +5
  • Research Article

Changeable density pseudocoloring with diffraction of dual phase gratings

  • Sep 01, 1992
  • Optics Communications
  • Fanglin Peng
  • Research Article
  • Citations4

Maximizing Young fringe visibility with a universal SU2 polarization gadget.

  • Jun 11, 2018
  • Optics letters
  • M Alonzo +2
  • Research Article
  • Citations19

Dynamical studies of gratings formed in polymer-dispersed liquid crystal films doped with a guest-host dye

  • Sep 01, 2000
  • Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics
  • Andy Y.-G Fuh +3
  • Research Article
  • Citations27

Holographic volume absorption grating in glass-like polymer recording material

  • Jan 01, 2008
  • Optics Express
  • V Matusevich +4
  • Research Article
  • Citations24

Imaging quality of multifocal intraocular lenses: automated assessment setup

  • Jun 21, 2013
  • Ophthalmic and Physiological Optics
  • Arnau Calatayud +4
  • Research Article
  • Citations1

Higher-order harmonics in bleached silver halide holograms

  • Oct 07, 2005
  • Optics and Lasers in Engineering
  • I Bányász
  • Research Article
  • Citations4

Observation of a fast-formed absorption grating and a slowly formed phase grating in undeveloped dichromated gelatin

  • Aug 01, 2001
  • Applied Optics
  • Yeung Lak Lee +4
  • Conference Article

Two-Wave Coupling Measurement of Grating Phases and Self-Diffraction Oscillations in a Photopolymer Film

  • Jan 01, 1998
  • Chong Hoon Kwak +3
  • Research Article
  • Citations4

Phase-shifting Jamin double-shearing interferometer based on polarization beam splitting film

  • Jun 01, 2012
  • Optik - International Journal for Light and Electron Optics
  • Lijuan Wang +4
  • Research Article
  • Citations8

Analysis of partially coherent light propagation through the soft X-ray interference lithography beamline at SSRF.

  • Apr 14, 2021
  • Journal of synchrotron radiation
  • Xiangyu Meng +9
  • Research Article
  • Citations28

Self-Filtering High-Resolution Dual-Sapphire-Fiber-Based High-Temperature Sensor

  • Jan 23, 2019
  • Journal of Lightwave Technology
  • Xun Yu +5
  • Research Article
  • Citations74

All-fiber multipath Mach⬜Zehnder interferometer based on a four-core fiber for sensing applications

  • Jul 29, 2016
  • Sensors and Actuators A: Physical
  • Chao Li +7
  • Research Article
  • Citations23

What is the maximum attainable visibility by a partially coherent electromagnetic field in Young's double-slit interference?

  • Jul 20, 2017
  • Optics Express
  • Ayman F Abouraddy
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.