Full-dose whole-body PET synthesis from low-dose PET using high-efficiency denoising diffusion probabilistic model: PET consistency model.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Positron Emission Tomography (PET) has been a commonly used imaging modality in broad clinical applications. One of the most important tradeoffs in PET imaging is between image quality and radiation dose: high image quality comes with high radiation exposure. Improving image quality is desirable for all clinical applications while minimizing radiation exposure is needed to reduce risk to patients. We introduce PET Consistency Model (PET-CM), an efficient diffusion-based method for generating high-quality full-dose PET images from low-dose PET images. It employs a two-step process, adding Gaussian noise to full-dose PET images in the forward diffusion, and then denoising them using a PET Shifted-window Vision Transformer (PET-VIT) network in the reverse diffusion. The PET-VIT network learns a consistency function that enables direct denoising of Gaussian noise into clean full-dose PET images. PET-CM achieves state-of-the-art image quality while requiring significantly less computation time than other methods. Evaluation with normalized mean absolute error (NMAE), peak signal-to-noise ratio (PSNR), multi-scale structure similarity index (SSIM), normalized cross-correlation (NCC), and clinical evaluation including Human Ranking Score (HRS) and Standardized Uptake Value (SUV) Error analysis shows its superiority in synthesizing full-dose PET images from low-dose inputs. In experiments comparing eighth-dose to full-dose images, PET-CM demonstrated impressive performance with NMAE of 1.278±0.122%, PSNR of 33.783±0.824dB, SSIM of 0.964±0.009, NCC of 0.968±0.011, HRS of 4.543, and SUV Error of 0.255±0.318%, with an average generation time of 62 s per patient. This is a significant improvement compared to the state-of-the-art diffusion-based model with PET-CM reaching this result 12× faster. Similarly, in the quarter-dose to full-dose image experiments, PET-CM delivered competitive outcomes, achieving an NMAE of 0.973±0.066%, PSNR of 36.172±0.801dB, SSIM of 0.984±0.004, NCC of 0.990±0.005, HRS of 4.428, and SUV Error of 0.151±0.192% using the same generation process, which underlining its high quantitative and clinical precision in both denoising scenario. We propose PET-CM, the first efficient diffusion-model-based method, for estimating full-dose PET images from low-dose images. PET-CM provides comparable quality to the state-of-the-art diffusion model with higher efficiency. By utilizing this approach, it becomes possible to maintain high-quality PET images suitable for clinical use while mitigating the risks associated with radiation. The code is availble at https://github.com/shaoyanpan/Full-dose-Whole-body-PET-Synthesis-from-Low-dose-PET-Using-Consistency-Model.

Similar Papers
  • Research Article
  • Citations123

Small-animal positron emission tomography as a tool for neuropharmacology

  • Jul 06, 2010
  • Trends in Pharmacological Sciences
  • Sophie Lancelot +1
  • Research Article

Distribution-Guided Multi-Tracer Brain PET Synthesis from Structural MRI with Class-Conditioned Weighted Diffusion.

  • Mar 14, 2026
  • UNC Libraries
  • Kelly S Giovanello +7
  • Research Article
  • Citations2

Noise-assisted hybrid attention networks for low-dose PET and CT denoising.

  • Oct 21, 2024
  • Medical physics
  • Hengzhi Xue +2
  • Conference Article
  • Citations1

Phased attenuation correction and respiratory motion compensation of pet image by using a ct images and multiple respiratory-phase mr images

  • Oct 01, 2011
  • Woo Hyun Nam +5
  • Research Article
  • Citations2

MO‐B‐350‐01: Functional/Molecular Imaging: PET for Treatment Planning and Response Assessment

  • Jun 01, 2008
  • Medical Physics
  • R Jeraj +1
  • Research Article
  • Citations167

Full-Dose PET Image Estimation from Low-Dose PET Image Using Deep Learning: a Pilot Study.

  • Nov 06, 2018
  • Journal of Digital Imaging
  • Sydney Kaplan +1
  • Research Article

Prediction of radioactive injection dosage for PET imaging

  • Feb 02, 2021
  • Soft Computing
  • Ebtesam Alsanea +1
  • Research Article
  • Citations21

Assessing and accounting for the impact of respiratory motion on FDG uptake and viable volume for liver lesions in free-breathing PET using respiration-suspended PET images as reference.

  • Aug 14, 2014
  • Medical Physics
  • Guang Li +5
  • Research Article
  • Citations31

Initial clinical experience using a new integrated in-line PET/CT system.

  • Nov 01, 2002
  • The British journal of radiology
  • H C Steinert +1
  • Research Article
  • Citations184

Cardiac positron emission tomography imaging

  • Jan 01, 2005
  • Seminars in Nuclear Medicine
  • Josef Machac
  • Abstract

Positive Positron Emission Tomography (PET) Scan in Non-Hodgkin Lymphoma Pre-Transplant Had No Impact On Relapse and Survival After Allogenenic Transplantation

  • Nov 16, 2012
  • Blood
  • Veronika Bachanova +4
  • Research Article
  • Citations6

PET/CT-guided biopsy with respiratory motion correction

  • Sep 11, 2019
  • International Journal of Computer Assisted Radiology and Surgery
  • Ruoqiao Zhang +7
  • Research Article
  • Citations2

Deep learning-based triple-tracer brain PET scanning in a single session: A simulation study using clinical data.

  • Jun 01, 2025
  • NeuroImage
  • Yiyi Hu +5
  • Research Article
  • Citations45

3D Compton image reconstruction method for whole gamma imaging

  • Nov 19, 2020
  • Physics in Medicine & Biology
  • Hideaki Tashima +8
  • PDF
  • Research Article
  • Citations9

Strategies for mitigating inter-crystal scattering effects in positron emission tomography: a comprehensive review

  • Sep 17, 2024
  • Biomedical Engineering Letters
  • Min Sun Lee +2
Cactus Communications logo