Full-energy peak efficiency and response function of 1 cm3 CdZnTe detectors

Show More
  • Abstract
  • PDF
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

The energy dependence of the full-energy peak (FEP) efficiency and response function of 1 cm3 CdZnTe detectors that use gamma rays were investigated in the present study. Specifically, full-energy peaks from 60 keV to 1.3 MeV were evaluated. 214Am, 133Ba, 137Cs, 54Mn, and 60Co radionuclides with good source activities were employed. The results showed that the absolute peak efficiencies decreased at higher energies, and the calculated (EGS5 code) efficiencies were nearly 70% greater than the experimental values when above 100 keV photon. Below 100 keV, disagreement is within 35%. The measured and calculated peak efficiencies peak agreed within 5% in a wide energy range when the “effective” of the crystal area was down to 0.8 x 0.8 cm2. Agreement corresponding to response function curve at the region of interest (full-energy peak) and Compton plateau region for 137Cs achieved once considering the 0.8 x 0.8 cm2 effective area of the crystal and the source plastic casing. The results of the present study provided important insights on the calibration of the FEP efficiency as a function of the gamma ray energy. The detectors must be individually calibrated to obtain reliable results.

Loading PDF

Similar Papers
  • Research Article
  • Citations35

HPGe detector absolute full-energy peak efficiency calibration including coincidence correction for circular disc sources

  • Sep 01, 2006
  • Journal of Physics D: Applied Physics
  • Mahmoud I Abbas
  • Research Article
  • Citations1

Towards the Reliability Check of Complementary Methods for the Precise Estimation of Peak Efficiency of a Long Run Used Germanium Detector in Low Activity Environmental Measurements

  • Aug 27, 2022
  • Journal of Electrical Electronics Engineering
  • M Margret +3
  • Research Article

Evaluating the uncertainty associated with computed values of the full-energy peak efficiency used in gamma spectrometry measurements.

  • Apr 01, 2026
  • Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine
  • D Gurau +3
  • Research Article
  • Citations29

Monte Carlo calculations of gamma ray response characteristics of cylindrical Ge(Li) detectors

  • Mar 01, 1970
  • Nuclear Instruments and Methods
  • B Lal +1
  • Research Article
  • Citations11

Effects of element composition in soil samples on the efficiencies of gamma energy peaks evaluated by the MCNP5 code

  • Jul 02, 2020
  • Nuclear Engineering and Technology
  • Vu Ngoc Ba +2
  • Research Article
  • Citations2

Experimental and GEANT4 simulated FEPE of NaI(Tl) detector for linear sources

  • Feb 05, 2025
  • Biomedical Physics & Engineering Express
  • Shahid Mansoor +4
  • Research Article
  • Citations10

Local efficiency variations in coaxial Ge(Li) detectors

  • Aug 01, 1972
  • Nuclear Instruments and Methods
  • I.S Sherman +1
  • Research Article
  • Citations31

Monte Carlo efficiency transfer method for full energy peak efficiency calibration of three type HPGe detectors: A coaxial N-type, a coaxial P-type and four BEGe detectors

  • Apr 17, 2006
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • Liu Liye +4
  • Research Article

Study the influences of the radionuclide depth distributions on the FEPE for the measurements of the soil activity using in situ HPGe gamma spectrometry

  • Jun 30, 2017
  • Nuclear Science and Technology
  • Hong Loan Truong Thi +4
  • Research Article

Calibration of HPGe Detector Efficiencies With Self-Absorption Correction of Gas Sphere Sources

  • Jan 01, 2019
  • Journal of Nuclear Engineering and Radiation Science
  • Waseem Khan +1
  • Research Article
  • Citations13

Full-energy peak determination from total efficiency and peak-to-total ratio calculations

  • Dec 26, 2020
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • Peki P Aguiar-Amado +2
  • Conference Article
  • Citations4

<title>Mercuric iodide x-ray and gamma-ray detectors for astronomy</title>

  • Jan 31, 2002
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Lodewijk Van Den Berg +6
  • Research Article
  • Citations12

Calculation of total and full energy peak efficiencies of Ge(Li) and NaI(Tl) detectors by introducing the mean chord length

  • Feb 01, 1976
  • Nuclear Instruments and Methods
  • Cihan Özmutlu +1
  • Research Article
  • Citations46

Relative efficiency of Ge(Li) gamma ray detectors from 0.5 to 12 MeV

  • Dec 01, 1971
  • Nuclear Instruments and Methods
  • B.P Singh +1
  • Research Article
  • Citations3

Steps Toward Optimizing HPGE Detector Efficiency in the Context of Low-Level Radioactivity Detection

  • Dec 15, 2023
  • Romanian Journal of Physics
  • Dalal Abdel Aziz +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.