• Home
  • Search
  • Functionality testing of an innovative biomechanically optimized and surface-modified orthodontic mini-screw-a comparative study.
  • Cite Icon3
  • https://doi.org/10.1007/s00056-023-00508-9Copy DOI Icon

Functionality testing of an innovative biomechanically optimized and surface-modified orthodontic mini-screw-a comparative study.

  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

The failure rate of orthodontic mini-screws depends strongly on primary stability and, thus, on insertion torque. Further improvement regarding the failure rate might be achieved by modifying the surface coating. Therefore, the aim of the study was to investigate the stability of anewly designed and surface-modified orthodontic mini-screw in beagle dogs. Newly designed mini-screws coated either with DOTIZE® or DOTIZE®-copper (DOT GmbH, Rostock, Germany; each: n = 24) were inserted in the mandibles of eight beagle dogs for aduration of 8months. Insertion and removal torque were measured. These data were compared to values generated by using the artificial bone material Sawbones® (Sawbones Europe AB, Malmö, Sweden). Experiments with and without torque limitation (each: n = 5) were run. The bone-to-implant contact rate and the amount of bone between the threads were examined. Statistical significance was set at P < 0.05. The success rates of the in vivo study reached high levels with 95.3% for the DOTIZE-coated and 90.5% for the DOTIZE-copper-coated screws, whereas the insertion and removal torque did not differ between the coatings. During insertion, atorque limitation of 20 Ncm was necessary to ensure that the recommended limit was not exceeded. The insertion in Sawbones without torque limitation revealed asignificantly higher torque compared to torque-limited insertion (18.2 ± 1.3 Ncm, 23.6 ± 1.3 Ncm). Bending occurred (n = 5) in the thread-free part of the mini-screw. Surface coating might be able to improve the performance of orthodontic mini-screws. The study showed high success rates and stable mini-screws until the end of observation. Further investigations are necessary.

Similar Papers
  • Research Article
  • Citations154

Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study

  • Jan 11, 2010
  • Clinical Oral Implants Research
  • Afsheen Tabassum +3
  • Research Article
  • Citations37

In-vitro comparison of different palatal sites for orthodontic miniscrew insertion: Effect of bone quality and quantity on primary stability.

  • Nov 24, 2018
  • American Journal of Orthodontics and Dentofacial Orthopedics
  • Carine Bourassa +6
  • PDF
  • Research Article
  • Citations15

Survival rate and stability of surface-treated and non-surface-treated orthodontic mini-implants: a randomized clinical trial.

  • Jan 01, 2023
  • Dental press journal of orthodontics
  • Janani Ravi +4
  • Dissertation

Effects of pilot hole size on miniscrew insertion torque and synthetic bone transparency

  • Jan 01, 2019
  • Chutimont Teekavanich
  • Dissertation

Applicability and integration of plasma sprayed hydroxyapatite coated AO cortical bone screws in equine bone

  • Mar 24, 2010
  • Timm Gudehus
  • Research Article
  • Citations26

Relationship Between Primary Stability and Crestal Bone Loss of Implants Placed with High Insertion Torque: A 3-Year Prospective Study.

  • Sep 01, 2016
  • The International Journal of Oral &amp; Maxillofacial Implants
  • Daniele De Santis +4
  • Research Article
  • Citations22

Resonance Frequency Analysis, Insertion Torque, and Bone to Implant Contact of 4 Implant Surfaces

  • Oct 31, 2014
  • Implant Dentistry
  • Maroun Dagher +3
  • Research Article
  • Citations1

Histomorphometric evaluation of cortical bone surrounding mini-screw: Why is the insertion torque critical for primary stability?

  • Jan 01, 2018
  • Biomedical Research
  • Hiroko Sunagawa Kojima +6
  • Research Article
  • Citations27

Comparison of Osteotome and Conventional Drilling Techniques for Primary Implant Stability: An In Vitro Study.

  • Mar 03, 2016
  • Journal of Oral Implantology
  • Ioanna N Tsolaki +5
  • Research Article
  • Citations3

The Effect of Increasing Thread Depth on the Initial Stability of Dental Implants: An In Vitro Study

  • Sep 07, 2024
  • Surgeries
  • Chiara Cucinelli +4
  • Research Article
  • Citations12

Prediction of primary stability via the force feedback of an autonomous dental implant robot

  • Dec 07, 2023
  • The Journal of prosthetic dentistry
  • Danying Chen +4
  • Research Article
  • Citations1

"Relationship between insertion torque and ISQ of 600 implants placed in soft bone with different surgical techniques." in vitro study.

  • Jul 01, 2025
  • Journal of stomatology, oral and maxillofacial surgery
  • Clarisse Brunel +3
  • Research Article
  • Citations178

Pedicle screw fixation strength: pullout versus insertional torque

  • Sep 01, 2004
  • The Spine Journal
  • Serkan Inceoglu +2
  • Research Article
  • Citations53

Is insertion torque correlated to bone–implant contact percentage in the early healing period? A histological and histomorphometrical evaluation of 17 human‐retrieved dental implants

  • Jul 07, 2009
  • Clinical Oral Implants Research
  • Marco Degidi +4
  • Research Article
  • Citations3

Socket Preservation Using Xenograft Does Not Impair Implant Primary Stability in Sheep: Clinical, Histological, and Histomorphometric Study.

  • Apr 21, 2020
  • Journal of Oral Implantology
  • Yaniv Mayer +2
Cactus Communications logo