Abstract

The advanced Soft X-ray (SXR) diagnostics setup devoted to studies of the SXR plasma emissivity focusing on the energy range of tungsten emission lines is at the moment a highly relevant and important for ITER/DEMO as W became a plasmafacing material and, therefore, plasma contamination by W and W transport in the plasma must be understood and monitored. The Gas Electron Multiplier (GEM) based SXR radiation detecting system under development by our group with a spatial and energy-resolved photon detecting chamber may become such a diagnostic setup; however, many physical, technical and technological aspects must be taken into consideration. This work presents the results of preliminary tests and simulations of the research into the optimal design of the detector’s internal chamber. The study of the influence of different GEM foils on the properties and distribution of the electron avalanche as well as the effect of the high rate photon flux on GEM foil performance was performed. Effect of electrodes alignment allowed choosing the gap distances which maximize electron transmission was also examined. Finally, the optimal readout structure design was identified suitable to collect a total formed charge effectively.

Similar Papers
  • Research Article

Effect of deformation due to stretching of the Gas Electron Multiplier (GEM) Foil

  • Apr 01, 2020
  • Journal of Physics: Conference Series
  • Shivali Malhotra +3
  • Research Article

Visual investigation of possible degradation in GEM foil under test

  • Oct 14, 2022
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • S Chatterjee +3
  • Conference Article
  • Citations3

GEM foil gain prediction

  • Aug 06, 2019
  • Timo Eero Hilden +3
  • Conference Article
  • Citations1

Radiation Effect On Gas Electron Multiplier Detector Performance

  • Jan 01, 2011
  • AIP conference proceedings
  • Kwang June Park +6
  • Research Article
  • Citations10

Quality assurance of GEM foils for the upgrade of the ALICE TPC

  • Jan 01, 2017
  • Journal of Instrumentation
  • M Ball +4
  • Research Article
  • Citations2

Production and validation of industrially produced large-sized GEM foils for the Phase-2 upgrade of the CMS muon spectrometer

  • Sep 27, 2023
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • D U J Sonnadara +99
  • Conference Article

Study of GEM Foil Etching Techniques on Detector Performance

  • Oct 16, 2021
  • F Ivone +2
  • Conference Article
  • Citations1

Optical quality control of Gas Electron Multiplier foils

  • Sep 01, 2014
  • S Cesar A Rodriguez +2
  • Research Article
  • Citations7

Operation of gas electron multiplier (GEM) with propane gas at low pressure and comparison with tissue-equivalent gas mixtures

  • Mar 02, 2016
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • L De Nardo +1
  • Research Article
  • Citations2

GEM based R&D for muon chambers of CBM experiment at FAIR

  • Jun 01, 2014
  • Journal of Instrumentation
  • A K Dubey +5
  • Research Article
  • Citations5

Gem detectors for X-ray astronomy

  • Sep 02, 2003
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • H Andersson +11
  • Research Article
  • Citations3

Development of thin gaseous ionization detectors for measurements of high-energy hadron beams

  • Apr 01, 2014
  • Journal of the Korean Physical Society
  • Kyong Sei Lee +5
  • Research Article
  • Citations4

Fast 2-D soft X-ray imaging device based on micro pattern gas detector

  • Sep 01, 2003
  • Nuclear Physics B - Proceedings Supplements
  • D Pacella +3
  • Research Article
  • Citations3

Determination of MHD mode structures using soft x-ray diagnostics in TCV

  • Jan 24, 2023
  • Plasma Physics and Controlled Fusion
  • M B Dreval +5
  • Research Article
  • Citations3

Development of a one-coordinate gaseous detector for wide angle diffraction studies

  • Apr 01, 2008
  • Journal of Instrumentation
  • V M Aulchenko +6
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.