• Home
  • Search
  • Generative Adversarial Networks for Noise Reduction in Low-Dose CT.
  • Cite Icon1081
  • https://doi.org/10.1109/tmi.2017.2708987Copy DOI Icon

Generative Adversarial Networks for Noise Reduction in Low-Dose CT.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Noise is inherent to low-dose CT acquisition. We propose to train a convolutional neural network (CNN) jointly with an adversarial CNN to estimate routine-dose CT images from low-dose CT images and hence reduce noise. A generator CNN was trained to transform low-dose CT images into routine-dose CT images using voxelwise loss minimization. An adversarial discriminator CNN was simultaneously trained to distinguish the output of the generator from routine-dose CT images. The performance of this discriminator was used as an adversarial loss for the generator. Experiments were performed using CT images of an anthropomorphic phantom containing calcium inserts, as well as patient non-contrast-enhanced cardiac CT images. The phantom and patients were scanned at 20% and 100% routine clinical dose. Three training strategies were compared: the first used only voxelwise loss, the second combined voxelwise loss and adversarial loss, and the third used only adversarial loss. The results showed that training with only voxelwise loss resulted in the highest peak signal-to-noise ratio with respect to reference routine-dose images. However, CNNs trained with adversarial loss captured image statistics of routine-dose images better. Noise reduction improved quantification of low-density calcified inserts in phantom CT images and allowed coronary calcium scoring in low-dose patient CT images with high noise levels. Testing took less than 10 s per CT volume. CNN-based low-dose CT noise reduction in the image domain is feasible. Training with an adversarial network improves the CNNs ability to generate images with an appearance similar to that of reference routine-dose CT images.

Similar Papers
  • Research Article
  • Citations4

Deep learning-based low-dose CT simulator for non-linear reconstruction methods.

  • Jun 06, 2024
  • Medical physics
  • Sjoerd A M Tunissen +5
  • Research Article
  • Citations41

StatNet: Statistical Image Restoration for Low-Dose CT using Deep Learning

  • May 28, 2020
  • IEEE Journal of Selected Topics in Signal Processing
  • Kihwan Choi +2
  • Conference Article
  • Citations27

Automated coronary artery calcification detection on low-dose chest CT images

  • Mar 20, 2014
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Yiting Xie +4
  • Research Article
  • Citations25

Evaluation of fully automated commercial software for Agatston calcium scoring on non-ECG-gated low-dose chest CT with different slice thickness.

  • Sep 24, 2022
  • European Radiology
  • Hyun Woo Kang +10
  • Conference Article
  • Citations1

A method to generate patient CT noise for deep learning network training

  • Apr 01, 2024
  • Minah Han +1
  • Research Article
  • Citations36

Low-Dose Lung CT Image Restoration Using Adaptive Prior Features From Full-Dose Training Database

  • Sep 27, 2017
  • IEEE Transactions on Medical Imaging
  • Yuanke Zhang +4
  • Book Chapter
  • Citations2

Noise Reduction with Detail Preservation in Low-Dose Dental CT Images by Morphological Operators and BM3D

  • Aug 15, 2020
  • Romulo Marconato Stringhini +3
  • Research Article
  • Citations2

Weakly supervised low-dose computed tomography denoising based on generative adversarial networks.

  • Aug 01, 2024
  • Quantitative imaging in medicine and surgery
  • Peixi Liao +7
  • Research Article
  • Citations53

One-stage pulmonary nodule detection using 3-D DCNN with feature fusion and attention mechanism in CT image

  • Apr 04, 2022
  • Computer Methods and Programs in Biomedicine
  • Yao-Sian Huang +4
  • Research Article
  • Citations10

Pure Vision Transformer (CT-ViT) with Noise2Neighbors Interpolation for Low-Dose CT Image Denoising.

  • Apr 15, 2024
  • Journal of imaging informatics in medicine
  • Luella Marcos +2
  • PDF
  • Research Article
  • Citations5

Low-dose abdominopelvic computed tomography in patients with lymphoma: An image quality and radiation dose reduction study

  • Aug 11, 2022
  • PLoS ONE
  • Sungjin Yoon +7
  • Conference Article
  • Citations13

Self Supervised Low Dose Computed Tomography Image Denoising Using Invertible Network Exploiting Inter Slice Congruence

  • Jan 01, 2023
  • Sutanu Bera +1
  • Research Article
  • Citations2

Noise-assisted hybrid attention networks for low-dose PET and CT denoising.

  • Oct 21, 2024
  • Medical physics
  • Hengzhi Xue +2
  • Research Article
  • Citations1

Evaluation for Osteoporosis Using Low-Dose CT Imaging of the Chest Obtained for Lung Cancer Screening: A Retrospective Study of 1,336 Patients.

  • May 01, 2026
  • Chest
  • Muhammad O Awiwi +8
  • Conference Article
  • Citations3

Unpaired learning with a data-dependent noise-generative model for low-dose CT sinogram restoration

  • Apr 07, 2023
  • Yang Liu +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.